Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent ; 146: 105025, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38697507

RESUMO

OBJECTIVES: To evaluate the mechanical, wear, antibacterial properties, and biocompatibility of injectable composite materials. METHODS: Two injectable composite resins (GU and BI), one flowable composite resin (FS), and one flowable compomer (DF), in A2 shade, were tested. Mechanical properties were tested via three-point bending test immediately after preparation and after 1-day, 7-day, 14-day, and 30-day water storage. Under water-PMMA slurry immersion, specimens were subjected to a 3-body wear test (10,000 cycles) against stainless steel balls, while the roughness, wear depth, and volume loss were recorded. After 1-day and 3-day MC3T3-E1 cell culture, cell viability was evaluated with CCK-8 test kits, while the cell morphology was observed under CLSM and SEM. Antibacterial properties on S. mutans were assessed via CFU counting, CLSM, and SEM observation. SPSS 26.0 was used for statistical analysis (α = 0.05). RESULTS: The mechanical properties were material-dependent and sensitive to water storage. Flexural strength ranked GU > FS > BI > DF at all testing levels. Three nanocomposites had better wear properties than DF. No significant difference on 1-day cell viability was found, but DF showed significantly lower cell proliferation than nanocomposites on 3-day assessment. GU and FS had more favourable cell adhesion and morphology. CFU counting revealed no significant difference, while FS presented a slightly thicker biofilm and BI showed relatively lower bacteria density. CONCLUSIONS: Injectable nanocomposites outperformed the compomer regarding mechanical properties, wear resistance, and biocompatibility. The tested materials presented comparable antibacterial behaviours. Flowable resin-based composites' performances are affected by multiple factors, and their compositions can be attributed. CLINICAL SIGNIFICANCE: A profound understanding of the mechanical, wear, and biological properties of the restorative material is imperative for the clinical success of dental restorations. The current study demonstrated superior properties of highly filled injectable composite resins, which imply their wider indications and better long-term clinical performances.


Assuntos
Antibacterianos , Materiais Biocompatíveis , Sobrevivência Celular , Resinas Compostas , Teste de Materiais , Streptococcus mutans , Propriedades de Superfície , Resinas Compostas/química , Resinas Compostas/farmacologia , Antibacterianos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Camundongos , Animais , Sobrevivência Celular/efeitos dos fármacos , Materiais Dentários/química , Compômeros/farmacologia , Água/química , Nanocompostos/química , Resistência à Flexão , Injeções , Polimetil Metacrilato/química
2.
J Dent ; 146: 105031, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38710315

RESUMO

OBJECTIVES: To investigate and compare the chemical and optical stability of four restorative composite materials: two injectable resins, one flowable resin and one compomer. METHODS: Two injectable nano-filled composite resins: G-aenial Universal (GU) and Beautifil Injectable XSL (BI), a flowable composite resin: Filtek Supreme Flowable (FS) and a compomer: Dyract Flow (DF), in A2 shade were tested and compared. Water sorption and solubility were conducted according to ISO4049:2019 standard; ICP-OES and F-ion selective electrode were used to test the elemental release; Degree of conversion (DC) was obtained by using FTIR; water contact angle was obtained by static sessile drop method, and a spectrophotometer was used for optical properties (ΔE⁎, ΔL⁎ and TP). SPSS 28.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. RESULTS: GU performed the best in water sorption and solubility, FS had the lowest elemental release, the best colour stability, and the highest DCIM and DC24-h. DF, the compomer had the lowest, and GU and BI, the injectable composites had the largest water contact angle, respectively. Correlations were found between water sorption and water solubility. CONCLUSIONS: The four composite restorative materials showed different chemical and optical behaviours. Overall, composite resins performed better than compomer, while additional laboratory and in vivo tests are necessary to obtain a more comprehensive comparison between injectable and flowable composite resins. Wsp and Wsl are influenced by many common factors, and the values are highly positively related. CLINICAL SIGNIFICANCE: A comprehensive understanding of materials is crucial before selecting materials for clinical practice. Composite resins rather than compomers are recommended because of their exceptional properties, which make them eligible for a wide range of clinical applications and an elongated lifespan.


Assuntos
Cor , Compômeros , Resinas Compostas , Materiais Dentários , Teste de Materiais , Solubilidade , Água , Resinas Compostas/química , Materiais Dentários/química , Água/química , Compômeros/química , Humanos , Restauração Dentária Permanente/métodos , Espectrofotometria , Espectroscopia de Infravermelho com Transformada de Fourier , Metacrilatos/química , Injeções , Poliuretanos/química , Nanocompostos/química , Propriedades de Superfície , Fenômenos Ópticos , Bis-Fenol A-Glicidil Metacrilato
3.
J Prosthet Dent ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38000966

RESUMO

STATEMENT OF PROBLEM: Reports on digitally fabricated complete dentures are increasing. However, comprehensive evidence-based research on their cost-efficiency and patient-reported outcome measures (PROMs) is lacking. PURPOSE: The purpose of this systematic review was to compare the cost-effectiveness and PROMs between digitally and conventionally fabricated complete dentures. MATERIAL AND METHODS: An electronic search of publications from 2011 to mid-2023 was established using PubMed/Medline, EBSCOhost, and Google Scholar. Retrospective, prospective, randomized controlled, and randomized crossover clinical studies on at least 10 participants were included. A total of 540 articles were identified and assessed at the title, abstract, and full article level, resulting in the inclusion of 14 articles. Data on cost, number of visits, patient satisfaction, and oral health-related quality of life were examined and reported. RESULTS: The systematic review included 572 digitally fabricated complete dentures and 939 conventionally fabricated complete dentures inserted in 1300 patients. Digitally fabricated complete dentures require less clinical time with a lower total cost, despite higher material costs compared with the conventional fabrication technique. Digitally and conventionally fabricated complete dentures were found to have significant effects on mastication efficiency, comfort, retention, stability, ease of cleaning, phonetics, and overall patient satisfaction, as well as social disability, functional limitation, psychological discomfort, physical pain, and handicap. CONCLUSIONS: Digitally fabricated complete dentures are more cost-effective than conventionally fabricated dentures. There are various impacts of conventionally and digitally fabricated complete dentures on PROMs, and they are not better than one another.

4.
J Dent ; 134: 104518, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37088259

RESUMO

OBJECTIVE: To explore and analyse the perspective of patients undergoing and recovering from nasopharyngeal carcinoma (NPC) therapy. METHODS: Thirty-three NPC patients at different stages of treatment were enroled. Seven were actively undergoing treatment, 13 were immediately post-treatment, and 13 were long-term. Patients were interviewed using a structured questionnaire based on a review of the literature that covered different phases of their treatment journey. The interview was recorded and transcribed for qualitative data analysis using a thematic inductive-deductive approach. RESULTS: Three main domains embracing aspects of NPC patients' experiences were identified; side effects, psychosocial well-being, and the role and support of healthcare workers. Side effects were experienced orally, locally, and systemically. Oral side effects (oral mucositis, xerostomia, altered taste, dysphagia) were the most significant challenge experienced by NPC patients. Locally, skin injury (desquamation, fibrosis, darkening of the skin, erythema, pruritus, and swelling around the neck region) and hair loss, resolved after cessation of therapy. Systemic side effects from the treatment were related to general weakness, weight loss and nausea. The psychosocial well-being of NPC patients was influenced by a range of issues including support (healthcare workers and family), pain management, functional limitations, nutritional needs, perceived level of information, emotion, and finances. CONCLUSION: NPC patients were significantly impacted based on the diagnosis, treatment and recovery phase affecting them locally, systemically, and psychologically. The role of family and healthcare staff was also influential in the overall treatment experience, and they have key roles to play in facilitating patients along their treatment journey. CLINICAL SIGNIFICANCE: Oral and general side effects from NPC treatment have significant impact on patients physical and emotional well-being. It is important for healthcare providers to have insights of these so as to understand and support patients during their treatment journey and recovery and be able to empathetically facilitate their clinical management.


Assuntos
Neoplasias Nasofaríngeas , Estomatite , Xerostomia , Humanos , Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas/tratamento farmacológico , Neoplasias Nasofaríngeas/patologia , Xerostomia/etiologia
5.
Dent Mater ; 39(3): 320-332, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36822895

RESUMO

OBJECTIVES: This study utilised an Artificial Intelligence (AI) method, namely 3D-Deep Convolutional Generative Adversarial Network (3D-DCGAN), which is one of the true 3D machine learning methods, as an automatic algorithm to design a dental crown. METHODS: Six hundred sets of digital casts containing mandibular second premolars and their adjacent and antagonist teeth obtained from healthy personnel were machine-learned using 3D-DCGAN. Additional 12 sets of data were used as the test dataset, whereas the natural second premolars in the test dataset were compared with the designs in (1) 3D-DCGAN, (2) CEREC Biogeneric, and (3) CAD for morphological parameters of 3D similarity, cusp angle, occlusal contact point number and area, and in silico fatigue simulations with finite element (FE) using lithium disilicate material. RESULTS: The 3D-DCGAN design and natural teeth had the lowest discrepancy in morphology compared with the other groups (root mean square value = 0.3611). The Biogeneric design showed a significantly (p < 0.05) higher cusp angle (67.11°) than that of the 3D-DCGAN design (49.43°) and natural tooth (54.05°). No significant difference was observed in the number and area of occlusal contact points among the four groups. FE analysis showed that the 3D-DCGAN design had the best match to the natural tooth regarding the stress distribution in the crown. The 3D-DCGAN design was subjected to 26.73 MPa and the natural tooth was subjected to 23.97 MPa stress at the central fossa area under physiological occlusal force (300 N); the two groups showed similar fatigue lifetimes (F-N curve) under simulated cyclic loading of 100-400 N. Designs with Biogeneric or technician would yield respectively higher or lower fatigue lifetime than natural teeth. SIGNIFICANCE: This study demonstrated that 3D-DCGAN could be utilised to design personalised dental crowns with high accuracy that can mimic both the morphology and biomechanics of natural teeth.


Assuntos
Inteligência Artificial , Coroas , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Porcelana Dentária , Algoritmos , Análise do Estresse Dentário
6.
J Prosthet Dent ; 2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36631366

RESUMO

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) technology has greatly improved the efficiency of the fabrication of dental prostheses. However, the design process (CAD stage) is still time-consuming and labor intensive. PURPOSE: The purpose of this feasibility study was to investigate the accuracy of a novel artificial intelligence (AI) system in designing biomimetic single-molar dental prostheses by comparing and matching them to the natural molar teeth. MATERIAL AND METHODS: A total of 169 maxillary casts were obtained from healthy dentate participants. The casts were digitized, duplicated, and processed with the removal of the maxillary right first molar. A total of 159 pairs of original and processed casts were input into the Generative Adversarial Networks (GANs) for training. In validation, 10 sets of processed casts were input into the AI system, and 10 AI-designed teeth were generated through backpropagation. Individual AI-designed teeth were then superimposed onto each of the 10 original teeth, and the morphological differences in mean Hausdorff distance were measured. True reconstruction was defined as correct matching between the AI-designed and original teeth with the smallest mean Hausdorff distance. The ratio of true reconstruction was calculated as the Intersection-over-Union. The reconstruction performance of the AI system was determined by the Hausdorff distance and Intersection-over-Union. RESULTS: Data of validation showed that the mean Hausdorff distance ranged from 0.441 to 0.752 mm and the Intersection-over-Union of the system was 0.600 (60%). CONCLUSIONS: This study demonstrated the feasibility of AI in designing single-molar dental prostheses. With further training and optimization of algorithms, the accuracy of biomimetic AI-designed dental prostheses could be further enhanced.

7.
Eur J Dent Educ ; 27(4): 1053-1059, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36715249

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the use of magnifying loupes (×2.5) on the quality of tooth preparation for complete coverage crowns; performed by predoctoral students using an objective and quantitative digital method. MATERIALS AND METHODS: Forty-two predoctoral students were randomly assigned into 2 groups to perform tooth preparation for a complete coverage crown on a mandibular first molar in a manikin, with and without the use of magnifying loupes. All preparations were digitally evaluated by PrepCheck 3.0 (Dentsply Sirona). Parameters including tooth reduction, total occlusal convergence (TOC), undercut, margin quality and surface quality were assessed. Continuous data were analysed using Paired t-tests or Wilcoxon Signed Ranks tests. Ordinal data were analysed by McNemer's tests. To further detect the majority pattern ( > 50%) in each group (with and without loupes), one-sample t-test or one-sample Wilcoxon Signed Rank test was performed. The level of significance was set at p = .001 after Bonferroni adjustments for multiple testing. RESULTS: No significant differences in the measured outcomes were found between the groups with or without the use of magnifying loupes (p > .002). The majority (>50%) of both groups had no undercuts (99.3% and 99.4% both p < .001) and the preparation type was within tolerance (81.6% and 85.3%, both p < .001) with acceptable margin (86.4% and 86.3%, both p < .001) and acceptable surface quality (99.0% and 99.1%, both p < .001). However, the majority of both groups underprepared occlusally (96.0% and 95.4%, both p < .001) and axially (65.3% and 67%, both p < .001). Only 30.0%-42.1% of the participants achieved the TOC within 0-20°. CONCLUSIONS: Within the limitations of this study, the use of magnification loupes does not appear to significantly improve the quality of tooth preparation for complete coverage crown. The TOC was also found to be overprepared and occlusally underprepared.


Assuntos
Educação em Odontologia , Dente , Humanos , Preparo do Dente/métodos , Coroas
8.
Int J Prosthodont ; 36(3): 331­337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35234751

RESUMO

PURPOSE: To determine and compare the accuracy and reliability of shade matching using the conventional and smartphone virtual methods. MATERIALS AND METHODS: A phantom head with both maxillary central incisors removed was set up. A central incisor of various standard shades was inserted into the phantom head. Five undergraduate and five postgraduate students were asked to select the closest shade to match the central incisor using the Vita Classic shade guide. The procedure was then repeated using images taken by a smartphone. Each technique was repeated three times. Differences in accuracy of shade matching between the two techniques for every shade tab and between undergraduate and postgraduate dental students were compared using chi-square statistical analysis. The P value was set at .001. Differences in intra-rater and inter-rater reliability between the two techniques and among the three sessions were compared using paired t test and analysis of variance (ANOVA), respectively, with a P value of .05. The reliability of both techniques was further measured using Cohen kappa statistical test. RESULTS: The smartphone virtual shade-matching technique showed significantly higher accuracy in shade matching with most of the tested shade tabs than the conventional method (P < .001), irrespective of observers' clinical experience. Higher repeatability was found in the virtual technique than the conventional technique, with higher intra-rater and inter-rater reliability observed. CONCLUSION: Smartphone virtual shade matching showed better accuracy and reliability than the conventional method and could be used as an alternative shade-matching method.


Assuntos
Pigmentação em Prótese , Smartphone , Humanos , Espectrofotometria , Cor , Reprodutibilidade dos Testes , Planejamento de Prótese Dentária , Incisivo , Percepção de Cores
9.
Dent Mater ; 39(1): 86-100, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36503862

RESUMO

OBJECTIVE: To seek dentine analogue materials in combined experimental, analytical, and numerical approaches on the mechanical properties and fatigue behaviours that could replace human dentine in a crown fatigue laboratory test. METHODS: A woven glass fibre-filled epoxy (NEMA grade G10; G10) and a glass fibre-reinforced polyamide-nylon (30% glass fibre reinforced polyamide-nylon 6,6; RPN) were investigated and compared with human dentine (HD). Flexural strength and elastic modulus (n = 10) were tested on beam-shaped specimens via three-point bending, while indentation hardness (n = 3) was tested after fracture. Abutment substrates of G10, RPN and HD were prepared and resin-bonded with monolithic lithium disilicate crowns (n = 10), then subjected to wet cyclic loading in a step-stress manner (500 N initial load, 100 N step size, 100,000 cycles per step, 20 Hz frequency). Data were statistically analysed using Kruskal-Wallis one-way ANOVA followed by post-hoc comparisons (α = 0.05). Survival probability estimation was performed by Mantel-Cox Log-Rank test with 95% confidence intervals. The fatigue failure load (FFL) and the number of cycles until failure (NCF) were evaluated with Weibull statistics. Finite Element Models of the fatigue test were established for stress distribution analysis and lifetime prediction. Fractographic observations were qualitatively analysed. RESULTS: The flexural strength of HD (164.27 ± 14.24 MPa), G10 (116.48 ± 5.93 MPa), and RPN (86.73 ± 3.56 MPa) were significantly different (p < 0.001), while no significant difference was observed in their flexural moduli (p = 0.377) and the indentation hardness between HD and RPN (p = 0.749). The wet cyclic fatigue test revealed comparable mean FFL and NCF of G10 and RPN to HD (p = 0.237 and 0.294, respectively) and similar survival probabilities for the three groups (p = 0.055). However, RPN promotes higher stability and lower deviation of fatigue test results than G10 in Weibull analysis and FEA. SIGNIFICANCE: Even though dentine analogue materials might exhibit similar elastic properties and fatigue performance to human dentine, different reliabilities of fatigue on crown-dentine analogues were shown. RPN seems to be a better substrate that could provide higher reliability and predictability of laboratory study results.


Assuntos
Cerâmica , Nylons , Humanos , Cerâmica/química , Reprodutibilidade dos Testes , Teste de Materiais , Propriedades de Superfície , Análise do Estresse Dentário , Porcelana Dentária/química , Coroas , Dentina , Desenho Assistido por Computador
10.
Int Dent J ; 73(4): 496-502, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36428104

RESUMO

OBJECTIVE: This in vitro study aimed to investigate enamel wear against 3 monolithic ceramics using 2 methods of measurement. METHODS: Three groups of standard flat monolithic ceramic specimens including zirconia-reinforced lithium silicate glass (Vita Suprinity, VITA Zahnfabrik), yttria-stabilised tetragonal zirconia (Lava Esthetic Zirconia), and lithium disilicate glass (IPS e.max Press, Ivoclar Vivadent) were prepared, with human enamel used as the control group. Each specimen was subjected to the 2-body wear test at 49 N for 250,000 cycles. Enamel antagonists were evaluated with micro-computed tomography (CT) and intra-oral scanner, allowing 3-dimensional images of vertical wear and volumetric loss of enamel antagonists to be calculated. One-way analysis of variance followed by Student-Newman-Keuls post hoc tests were used to examine the differences in vertical wear/volumetric loss amongst the groups. Paired t tests and intra-class correlations were used to compare vertical wear/volumetric loss between the micro-CT and intra-oral scanner groups. RESULTS: No significant difference in vertical wear was found amongst all groups. More volumetric loss was found in all test groups than in the control group (P < .001), but no significant difference was found amongst the test groups. There was a moderate positive correlation (r = 0.535, P = .033) between the vertical wear and volumetric loss. No significant difference between the 2 methods of measurement was found. CONCLUSIONS: Monolithic ceramics induce more enamel wear than natural teeth. Both micro-CT and intra-oral scanners can be used for measuring tooth wear with similar performance.


Assuntos
Cerâmica , Zircônio , Humanos , Microtomografia por Raio-X , Esmalte Dentário/diagnóstico por imagem , Teste de Materiais , Propriedades de Superfície
11.
J Mech Behav Biomed Mater ; 131: 105256, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35508087

RESUMO

This study aimed to compare the occlusal morphology and fracture behavior of lithium disilicate ceramic dental crowns on 12 human participants' premolar #45 designed by a knowledge-based AI (CEREC, biogeneric individual function, BI) and different human personnel (experienced technician, TD, and trained dental students, AD) using CAD software. Digital datasets of crown design were best-fit aligned with the original teeth to evaluate profile and volume discrepancies of the occlusal morphology, and difference in the functional cuspal angle. Milled and sintered lithium disilicate crowns were resin-luted to 3D-printed dental casts and were subjected to axial load-to-fracture test. The fracture loads and failure modes were recorded and examined. Repeated measures ANOVA with LSD post-hoc test, Kruskal-Wallis test, Pearson's correlation coefficient, paired t-test, and chi-square exact test were used for statistical analyses (α = 0.05). BI-generated crowns showed the highest occlusal profile discrepancy (0.3677 ± 0.0388 mm), whereas human-CAD designed crowns showed higher conformity to the original teeth (0.3254 ± 0.0515 mm for TD, 0.3571 ± 0.0820 for AD; z-difference method; p < 0.001). Cusp angle values were significantly different in all groups except BI and TD (54.76 ± 3.81° for the original teeth, 70.84 ± 4.31° for BI, 67.45 ± 5.30° for TD, and 62.30 ± 7.92° for AD; p < 0.001). Although all three groups of crown designs could achieve clinically acceptable fracture resistance (1556.09 ± 525.68 N for BI, 1486.00 ± 520.08 N for TD, 1425.77 ± 433.34 for AD; p = 0.505) such that no significant difference in fracture strength was found, most crowns presented catastrophic bulk fracture that was not clinically restorable because of the substrate fracture. Group BI had a significantly higher percentage of restorable substrate damage than TD (p = 0.014) and AD (p < 0.001). In conclusion, in designing lithium disilicate dental crown, CAD design with human may be better than knowledge-based AI.


Assuntos
Desenho Assistido por Computador , Coroas , Inteligência Artificial , Cerâmica , Porcelana Dentária , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais
12.
Dent Mater J ; 41(2): 249-255, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34866116

RESUMO

The aim of this study was to investigate the effects of supporting dies with different mechanical properties on the fracture strengths and failure modes of monolithic zirconia crowns, and identify a suitable die material for testing high-strength ceramic restorations. Thirty six dies from teeth, porous titanium and composite-resin with 36 zirconia crowns were fabricated based on 3D model. Crowns were cemented, then underwent load-to-fracture testing. Fractographic analysis was performed with scanning electron microscopy, and finite element analysis was made. During loading, a high stress concentration zone formed near the loading point and on surface of die. Cracks generated on failure penetrated the crown and extended to die in 9 teeth group specimens, while composite-resin samples exhibited fracture of both crowns and dies. All dies remained intact in porous titanium group. Fracture mode was undistinguishable in all groups. It was concluded that porous titanium appears suitable as die material for dental restorations with high fracture strength.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Cerâmica , Coroas , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Dente Molar , Zircônio
13.
Materials (Basel) ; 14(9)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946477

RESUMO

The aim of this in vitro study was to investigate the microgaps at the implant-abutment interface when zirconia (Zr) and CAD/CAM or cast Co-Cr abutments were used. METHODS: Sixty-four conical connection implants and their abutments were divided into four groups (Co-Cr (milled, laser-sintered and castable) and Zirconia (milled)). After chewing simulation (300,000 cycles, under 200 N loads at 2 Hz at a 30° angle) and thermocycling (10,000 cycles, 5 to 50 °C, dwelling time 55 s), the implant-abutment microgap was measured 14 times at each of the four anatomical aspects on each specimen by using a scanning electron microscope (SEM). Kruskal-Wallis and pair-wise comparison were used to analyze the data (α = 0.05). RESULTS: The SEM analysis revealed smaller microgaps with Co-Cr milled abutments (0.69-8.39 µm) followed by Zr abutments (0.12-6.57 µm), Co-Cr sintered (7.31-25.7 µm) and cast Co-Cr (1.68-85.97 µm). Statistically significant differences were found between milled and cast Co-Cr, milled and laser-sintered Co-Cr, and between Zr and cast and laser-sintered Co-Cr (p < 0.05). CONCLUSIONS: The material and the abutment fabrication technique affected the implant-abutment microgap magnitude. The Zr and the milled Co-Cr presented smaller microgaps. Although the CAD/CAM abutments presented the most favorable values, all tested groups had microgaps within a range of 10 to 150 µm.

15.
Clin Implant Dent Relat Res ; 23(1): 43-53, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33180980

RESUMO

BACKGROUND: Conventional freehand immediate placement of dental implants is technically challenging in the jaw reconstructive surgery. Computer-aided surgery might be the best solution, however, there has not been any standard approach to ensure the accuracy and efficiency of simultaneous dental implants in fibula flap jaw reconstruction. PURPOSE: We aim to evaluate the clinical outcome of simultaneous dental implant in fibula flap using the "three-in-one" patient-specific surgical guide (3-in-1-PSSG) in an open-label, prospective, single-arm, and single-center clinical trial. MATERIALS AND METHODS: A novel computer-aided designed and three-dimensional (3D) printed 3-in-1-PSSG, which contains functions of fibula segmentation, surgical plate positioning and implant placement, was used to facilitate the reconstructive surgery and simultaneous dental implant placement. The intraoperative success of dental implant placement, implant survival rate and accuracy of dental implant placement were reported. RESULTS: From November 2018 to June 2020, 15 consecutive patients with 48 dental implants were enrolled in this study. Fifteen 3-in-1-PSSGs were fabricated with a mean number of dental implants per guide of 3.2 ± 1.5. The intraoperative success rate of this approach was 14 out of 15. With an average follow-up period of 40 weeks, the overall implant survival rate was 83.3% (40/48). Eight implants were removed due to two fibula flap failures. The mean deviation at the implant platform and implant apex were 2.8 mm (interquartile range [IQR]: 1.9-3.4) and 3.2 mm (IQR: 2.0-4.6), and the angular deviation was 2.5° (IQR: 1.1-6.8). CONCLUSIONS: Our preliminary data indicated that the 3D printed 3-in-1-PSSG facilitated simultaneous dental implant in fibula flap jaw reconstruction with a favorable intraoperative success and short-term clinical outcome. It might be a viable alternative to allow one-step immediate oral rehabilitation in patients underwent jaw reconstruction with free flaps. Long-term results with a larger sample size are warranted.


Assuntos
Implantes Dentários , Retalhos de Tecido Biológico , Implantação Dentária Endóssea , Fíbula/cirurgia , Retalhos de Tecido Biológico/cirurgia , Humanos , Estudos Prospectivos
16.
Artigo em Inglês | MEDLINE | ID: mdl-32679828

RESUMO

Sodium hypochlorite (NaOCl), an effective endodontic irrigant against Enterococcus faecalis (EF), is harmful to periapical tissues. Natural pineapple-orange eco-enzymes (M-EE) and papaya eco-enzyme (P-EE) could be potential alternatives. This study aimed to assess the antimicrobial efficacy of M-EE and P-EE at different concentrations and fermentation periods against EF, compared to 2.5% NaOCl. Fermented M-EE and P-EE (3 and 6 months) at various concentrations were mixed with EF in a 96-well plate incubated for 24 h anaerobically. Minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of M-EE and P-EE were determined via EF growth observation. EF inhibition was quantitatively measured and compared between different irrigants using the one-way analysis of variance (ANOVA), and different fermentation periods using the independent-samples T-test. M-EE and P-EE showed MIC at 50% and MBC at 100% concentrations. There was no significant difference in antimicrobial effect when comparing M-EE and P-EE at 50% and 100% to 2.5% NaOCl. P-EE at 6 months fermentation exhibited higher EF inhibition compared to 3 months at concentrations of 25% (p = 0.017) and 0.78% (p = 0.009). The antimicrobial properties of M-EE and P-EE, at both 100% and 50% concentrations, are comparable to 2.5% NaOCl. They could therefore be potential alternative endodontic irrigants, but further studies are required.


Assuntos
Anti-Infecciosos/farmacologia , Enterococcus faecalis , Frutas/química , Animais , Enterococcus faecalis/efeitos dos fármacos , Humanos , Hipoclorito de Sódio/efeitos adversos , Hipoclorito de Sódio/farmacologia
17.
Microb Pathog ; 139: 103896, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31794816

RESUMO

INTRODUCTION: Candida albicans possesses the ability to switch rapidly between yeast to hyphal forms. Hyphal formation is a remarkable pathogenic characteristic, which allows C. albicans to invade into host cells. OBJECTIVES: This study was to investigate the role of the C. albicans SAP9 gene in hyphal formation and invasion ability. METHODS: The morphology of fungal cells in the hyphal-inducing liquid media (YPD+10% fetal bovine serum) was observed by the microscopy. And the morphology of the colony on solid agar plates of YPD+10% fetal bovine serum was photographed by the digital camera. The mRNA expressions of hypha-associated genes in serum medium were also analyzed by real time PCR. Then for the interaction between C. albicans and oral epithelial cells, endocytosis essay, invasion essay and damage assay were performed to compare the differences between the sap9Δ/Δ mutant strain and wild type strain. RESULTS: Compared with the wild type strain, the sap9Δ/Δ mutant strain exhibited a deficient yeast-to-hyphal morphological transition under serum hyphal-inducing conditions. Furthermore, the SAP9 knockout strain revealed a significant down-regulation of the expression of EFG1 (~40%), which is a transcription factor gene that mediates hyphae formation in C. albicans. Compared with the wild type strain, a 70% reduction in the endocytosis of the sap9Δ/Δ mutant strain by host cells was observed, as well as a 25% attenuation of active penetration and a 40% attenuation of host cell damage (P <0.05). CONCLUSIONS: Our data strongly suggests that C. albicans Sap9 is a potential hyphal-associated factor that responds to serum hyphal-inducing stimuli via a cAMP-protein kinase A pathway mediated by EFG1, and contributes to the process of invasion of Candida into the epithelial cells, leading to host cell damage.


Assuntos
Ácido Aspártico Endopeptidases/metabolismo , Candida albicans/fisiologia , Candidíase Bucal/metabolismo , Candidíase Bucal/microbiologia , Proteínas Fúngicas/metabolismo , Interações Hospedeiro-Patógeno , Mucosa Bucal/metabolismo , Mucosa Bucal/microbiologia , Ácido Aspártico Endopeptidases/genética , Candidíase Bucal/patologia , Linhagem Celular , Proteínas Fúngicas/genética , Regulação Fúngica da Expressão Gênica , Hifas , Mucosa Bucal/patologia , Mutação
18.
J Prosthodont Res ; 62(4): 436-442, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29731271

RESUMO

PURPOSE: The aim of this study was to investigate and quantify the effect of preparation design parameters on a premolar restored with two different CAD/CAM ceramic crowns by three-dimensional finite element analysis (FEA). METHODS: A restored human first premolar was digitized by a micro-CT scanner and a 3D model was created by a medical image processing software (Mimics). Following segmentation, dentine and ceramic were extracted by a surface meshing software (3-matic). Models with different preparation designs with three convergence angles (6°, 12° and 20°) and two preparation heights (3.1mm and 4.1mm) were produced. Mesh generation for models was performed in IA-FEMesh software with a lithium disilicate glass ceramic (LD, E=95.9GPa) and a polymer-infiltrated ceramic (PIC, E=30.1GPa) as the restorative materials. A 5-mm diameter stainless steel hemisphere was employed as an indenter. Twelve models were analyzed numerically in Abaqus™. RESULTS: The results indicated that preparation height was found to be a major factor affecting stress distribution in different components. In all models, the maximum principal stress of the ceramic crowns was found in contact area against the indenter. This stress was lesser in the longer abutment than the shorter one and it was greater for LD ceramic. Convergence angle had limited effect on stress distribution of ceramic crown in all models. CONCLUSIONS: The preparation height appeared to play a more important role in the stress distribution of ceramic crown than the convergence angle.


Assuntos
Dente Pré-Molar , Cerâmica , Coroas , Materiais Dentários , Restauração Dentária Permanente , Análise de Elementos Finitos , Maxila , Preparo Prostodôntico do Dente/métodos , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional , Estresse Mecânico , Tomografia Computadorizada por Raios X/métodos
19.
Dent Mater ; 34(7): e149-e157, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29653725

RESUMO

OBJECTIVES: The purpose of this study was to estimate the fatigue life of premolars restored with two dental ceramics, lithium disilicate (LD) and polymer infiltrated ceramic (PIC) using the numerical method and compare it with the published in vitro data. METHODS: A premolar restored with full-coverage crown was digitized. The volumetric shape of tooth tissues and crowns were created in Mimics®. They were transferred to IA-FEMesh for mesh generation and the model was analyzed with Abaqus. By combining the stress distribution results with fatigue stress-life (S-N) approach, the lifetime of restored premolars was predicted. RESULTS: The predicted lifetime was 1,231,318 cycles for LD with fatigue load of 1400N, while the one for PIC was 475,063 cycles with the load of 870N. The peak value of maximum principal stress occurred at the contact area (LD: 172MPa and PIC: 96MPa) and central fossa (LD: 100MPa and PIC: 64MPa) for both ceramics which were the most seen failure areas in the experiment. In the adhesive layer, the maximum shear stress was observed at the shoulder area (LD: 53.6MPa and PIC: 29MPa). SIGNIFICANCE: The fatigue life and failure modes of all-ceramic crown determined by the numerical method seem to correlate well with the previous experimental study.


Assuntos
Cerâmica/química , Coroas , Materiais Dentários/química , Porcelana Dentária/química , Falha de Restauração Dentária , Dente Pré-Molar , Desenho Assistido por Computador , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais , Estresse Mecânico
20.
J Mech Behav Biomed Mater ; 59: 304-313, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26896763

RESUMO

PURPOSE: The aim of this study was to measure the mechanical properties and fatigue behavior of three contemporary used dental ceramics, zirconia Cercon(®) (ZC), lithium disilicate e.max(®) CAD (LD), and polymer-infiltrated ceramic Enamic(®) (PIC). METHODS: Flexural strength of each CAD/CAM ceramic was measured by three point bending (n=15) followed by Weibull analysis. Elastic modulus was calculated from the load-displacement curve. For cyclic fatigue loading, sinusoidal loading with a frequency of 8Hz with minimum load 3N were applied to these ceramics (n=24) using three point bending from 10(3) to 10(6) cycles. Fatigue limits of these ceramics were predicted with S-N fatigue diagram. Fracture toughness and Vickers hardness of the ceramics were measured respectively by single edge V-notch beam (SEVNB) and microindentation (Hv 0.2) methods. Chemical compositions of the materials׳ surfaces were analyzed by EDS, and microstructural analysis was conducted on the fracture surfaces by SEM. One-way ANOVA was performed and the level of significance was set at 0.05 to analyze the numerical results. RESULTS: The mean flexural strength of ZC, LD, and PIC was respectively 886.9, 356.7, and 135.8MPa. However, the highest Weibull modulus belonged to PIC with 19.7 and the lowest was found in LD with 7.0. The fatigue limit of maximum load for one million cycles of ZC, LD, and PIC was estimated to be 500.1, 168.4, and 73.8GPa. The mean fracture toughness of ZC, LD, and PIC was found to be respectively 6.6, 2.8, and 1.4MPam(1/2), while the mean Vickers hardness was 1641.7, 676.7, and 261.7Hv. Fracture surfaces followed fatigue loading appeared to be smoother than that after monotonic loading. CONCLUSIONS: Mechanical properties of ZC were substantially superior to the two other tested ceramics, but the scattering of data was the least in PIC. The fatigue limit was found to be approximately half of the mean flexural strength for all tested ceramics.


Assuntos
Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Desenho Assistido por Computador , Módulo de Elasticidade , Dureza , Teste de Materiais , Zircônio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...