Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
4.
Am J Health Syst Pharm ; 75(4): 199-211, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29339374

RESUMO

PURPOSE: Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. METHODS: Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. RESULTS: Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. CONCLUSION: A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use.


Assuntos
Antineoplásicos/toxicidade , Composição de Medicamentos/normas , Monitoramento Ambiental/normas , Contaminação de Equipamentos/prevenção & controle , Serviço de Farmácia Hospitalar/normas , Ciclofosfamida/toxicidade , Composição de Medicamentos/instrumentação , Composição de Medicamentos/métodos , Monitoramento Ambiental/métodos , Fluoruracila/toxicidade , Hospitais Comunitários/métodos , Hospitais Comunitários/normas , Humanos , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/normas , Serviço de Farmácia Hospitalar/métodos
5.
Hosp Pharm ; 49(4): 355-62, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24958942

RESUMO

PURPOSE: Hazardous drug residue on the exterior surface of drug vials poses a potential risk for exposure of health care workers involved in handling these products. The purpose of this article is to heighten the awareness of this serious issue and to evaluate a commercial manufacturing process for removing and containing hazardous drug (HD) residue on exterior vial surfaces. Additionally, findings from this study are interpreted, incorporated into the current body of evidence, and discussed by experts in this field. METHODS: This study includes separate evaluations for the presence or absence of surface drug contamination on the vials of 3 HD products: 5-fluorouracil, cisplatin, and methotrexate. The drug products were packaged in vials using a patented prewashing/decontamination method, application of a polyvinylchloride (PVC) base, and use of clear glass vials. An additional step of encasing the vial in a shrink-wrapped sheath was used for 5-fluorouracil and cisplatin. RESULTS: Of all 5-fluorouracil (110 vials), methotrexate (60 vials), and cisplatin (60 vials) tested, only 2 had detectable amounts of surface residue. One 5-fluorouracil vial was found to have approximately 4 mg of 5-fluorouracil on the surface of the vial. The second contaminated vial was cisplatin, which was discovered to have 131 ng of platinum, equal to 200 ng of cisplatin or 0.2 µL of cisplatin solution, on the vial sheath. CONCLUSION: Using validated extraction and analytic methods, all but 2 of the 230 tested vials were found to be free of surface drug contamination. Pharmacy leaders need to take an active role in promoting the need for clean HD vials. Manufacturers should be required to provide their clients with data derived from externally validated analytic studies, reporting the level of HD contamination on the exterior of their vial products.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...