Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Neurophysiol ; 127(3): 1781-93, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26780994

RESUMO

OBJECTIVE: Validate independent component analysis (ICA) for removal of EMG contamination from EEG, and demonstrate a heuristic, based on the gradient of EEG spectra (slope of graph of log EEG power vs log frequency, 7-70 Hz) from paralysed awake humans, to automatically identify and remove components that are predominantly EMG. METHODS: We studied the gradient of EMG-free EEG spectra to quantitatively inform the choice of threshold. Then, pre-existing EEG from 3 disparate experimental groups was examined before and after applying the heuristic to validate that the heuristic preserved neurogenic activity (Berger effect, auditory odd ball, visual and auditory steady state responses). RESULTS: (1) ICA-based EMG removal diminished EMG contamination up to approximately 50 Hz, (2) residual EMG contamination using automatic selection was similar to manual selection, and (3) task-induced cortical activity remained, was enhanced, or was revealed using the ICA-based methodology. CONCLUSION: This study further validates ICA as a powerful technique for separating and removing myogenic signals from EEG. Automatic processing based on spectral gradients to exclude EMG-containing components is a conceptually simple and valid technique. SIGNIFICANCE: This study strengthens ICA as a technique to remove EMG contamination from EEG whilst preserving neurogenic activity to 50 Hz.


Assuntos
Eletroencefalografia/métodos , Eletromiografia/métodos , Paralisia/fisiopatologia , Análise de Componente Principal/métodos , Estimulação Acústica/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paralisia/diagnóstico , Estimulação Luminosa/métodos , Adulto Jovem
2.
Physiol Meas ; 36(7): 1469-84, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26020164

RESUMO

Electroencephalography (EEG) is challenged by high cost, immobility of equipment and the use of inconvenient conductive gels. We compared EEG recordings obtained from three systems that are inexpensive, wireless, and/or dry (no gel), against recordings made with a traditional, research-grade EEG system, in order to investigate the ability of these 'non-traditional' systems to produce recordings of comparable quality to a research-grade system. The systems compared were: Emotiv EPOC (inexpensive and wireless), B-Alert (wireless), g.Sahara (dry) and g.HIamp (research-grade). We compared the ability of the systems to demonstrate five well-studied neural phenomena: (1) enhanced alpha activity with eyes closed versus open; (2) visual steady-state response (VSSR); (3) mismatch negativity; (4) P300; and (5) event-related desynchronization/synchronization. All systems measured significant alpha augmentation with eye closure, and were able to measure VSSRs (although these were smaller with g.Sahara). The B-Alert and g.Sahara were able to measure the three time-locked phenomena equivalently to the g.HIamp. The Emotiv EPOC did not have suitably located electrodes for two of the tasks and synchronization considerations meant that data from the time-locked tasks were not assessed. The results show that inexpensive, wireless, or dry systems may be suitable for experimental studies using EEG, depending on the research paradigm, and within the constraints imposed by their limited electrode placement and number.


Assuntos
Encéfalo/fisiologia , Eletroencefalografia/economia , Eletroencefalografia/instrumentação , Tecnologia sem Fio/economia , Tecnologia sem Fio/instrumentação , Adulto , Idoso , Ritmo alfa/fisiologia , Percepção Auditiva/fisiologia , Sincronização Cortical/fisiologia , Eletroencefalografia/métodos , Potenciais Evocados P300 , Feminino , Dedos/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Atividade Motora/fisiologia , Fatores de Tempo , Percepção Visual/fisiologia , Adulto Jovem
3.
Int J Psychophysiol ; 97(3): 277-84, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25455426

RESUMO

The serious impact of electromyogram (EMG) contamination of electroencephalogram (EEG) is well recognised. The objective of this research is to demonstrate that combining independent component analysis with the surface Laplacian can eliminate EMG contamination of the EEG, and to validate that this processing does not degrade expected neurogenic signals. The method involves sequential application of ICA, using a manual procedure to identify and discard EMG components, followed by the surface Laplacian. The extent of decontamination is quantified by comparing processed EEG with EMG-free data that was recorded during pharmacologically induced neuromuscular paralysis. The combination of the ICA procedure and the surface Laplacian, with a flexible spherical spline, results in a strong suppression of EMG contamination at all scalp sites and frequencies. Furthermore, the ICA and surface Laplacian procedure does not impair the detection of well-known, cerebral responses; alpha activity with eyes-closed; ERP components (N1, P2) in response to an auditory oddball task; and steady state responses to photic and auditory stimulation. Finally, more flexible spherical splines increase the suppression of EMG by the surface Laplacian. We postulate this is due to ICA enabling the removal of local muscle sources of EMG contamination and the Laplacian transform being insensitive to distant (postural) muscle EMG contamination.


Assuntos
Eletromiografia , Potenciais Evocados/fisiologia , Músculo Esquelético/fisiologia , Análise de Componente Principal , Couro Cabeludo/fisiologia , Processamento de Sinais Assistido por Computador , Estimulação Acústica , Adulto , Idoso , Mapeamento Encefálico/efeitos adversos , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Descanso
4.
J Clin Neurophysiol ; 24(3): 232-43, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17545826

RESUMO

A study was performed to investigate and compare the relative performance of blind signal separation (BSS) algorithms at separating common types of contamination from EEG. The study develops a novel framework for investigating and comparing the relative performance of BSS algorithms that incorporates a realistic EEG simulation with a known mixture of known signals and an objective performance metric. The key finding is that although BSS is an effective and powerful tool for separating and removing contamination from EEG, the quality of the separation is highly dependant on the type of contamination, the degree of contamination, and the choice of BSS algorithm. BSS appears to be most effective at separating muscle and blink contamination and less effective at saccadic and tracking contamination. For all types of contamination, principal components analysis is a strong performer when the contamination is greater in amplitude than the brain signal whereas other algorithms such as second-order blind inference and Infomax are generally better for specific types of contamination of lower amplitude.


Assuntos
Algoritmos , Artefatos , Encéfalo/fisiologia , Eletroencefalografia , Ruído/efeitos adversos , Estatística como Assunto , Piscadela , Mapeamento Encefálico , Humanos , Movimentos Sacádicos , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...