Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rep Pract Oncol Radiother ; 27(2): 344-351, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36299375

RESUMO

FLASH radiotherapy (RT) is a technique involving the delivery of ultra-high dose rate radiation to the target. FLASH-RT has been shown to reduce radiation-induced toxicity in healthy tissues without compromising the anti-cancer effects of treatment compared to conventional radiation therapy. In the present article, we review the published data on FLASH-RT and discuss the current state of knowledge of this novel approach. We also highlight the technological constraints and complexity of FLASH-RT and describe the physics underlying this modality, particularly how technology supports energy transfer by ionising radiation (e.g., beam on/off sequence, pulse-energy load, intervals). We emphasise that current preclinical experience is mostly based on FLASH electrons and that clinical application of FLASH-RT is very limited. The incorporation of FLASH-RT into routine clinical radiotherapy will require the development of devices capable of producing FLASH photon beams.

2.
Rep Pract Oncol Radiother ; 26(6): 1029-1034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992877

RESUMO

BACKGROUND: The availability of linear accelerators (linac) for research purposes is often limited and therefore alternative radiation sources are needed to conduct radiobiological research. The National Centre for Radiation Research in Poland recently developed an intraoperative mobile linac that enables electron irradiation at energies ranging from 4 to 12 MeV and dose rates of 5 or 10 Gy/min. The present study was conducted to evaluate the electron beam parameters of this intraoperative linac and to verify the set-up to evaluate out-of-field doses in a water phantom, which were determined through dosimetric and biological response measurements. MATERIALS AND METHODS: The distribution of radiation doses along and across the radiation beam were measured in a water phantom using a semiconductor detector and absolute doses using an ionisation chamber. Two luminal breast cancer cell lines (T-47D and HER2 positive SK-BR-3) were placed in the phantom to study radiation response at doses ranging from 2 to 10 Gy. Cell response was measured by clonogenic assays. RESULTS AND CONCLUSION: The electron beam properties, including depth doses and profiles, were within expected range for the stated energies. These results confirm the viability of this device and set-up as a source of megavoltage electrons to evaluate the radiobiological response of tumour cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...