Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Healthcare (Basel) ; 11(18)2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37761669

RESUMO

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

2.
J Appl Oral Sci ; 26: e20180004, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30133672

RESUMO

Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Assuntos
Silicatos de Alumínio/química , Cerâmica/química , Desenho Assistido por Computador , Preparo da Cavidade Dentária/métodos , Porcelana Dentária/química , Restaurações Intracoronárias/métodos , Fraturas dos Dentes , Resinas Acrílicas/química , Análise de Variância , Resinas Compostas/química , Falha de Restauração Dentária , Análise do Estresse Dentário , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Teste de Materiais , Dente Molar , Poliuretanos/química , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
3.
J. appl. oral sci ; 26: e20180004, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-954510

RESUMO

Abstract Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Assuntos
Humanos , Cerâmica/química , Desenho Assistido por Computador , Preparo da Cavidade Dentária/métodos , Porcelana Dentária/química , Silicatos de Alumínio/química , Restaurações Intracoronárias/métodos , Poliuretanos/química , Valores de Referência , Fraturas dos Dentes , Resinas Acrílicas/química , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Resinas Compostas/química , Falha de Restauração Dentária , Análise de Elementos Finitos , Análise do Estresse Dentário , Módulo de Elasticidade , Dente Molar
4.
Braz Dent J ; 28(5): 624-631, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29215689

RESUMO

The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Assuntos
Hemostáticos , Cimentos de Resina/química , Cor , Microscopia Eletrônica de Varredura , Soluções , Análise Espectral , Propriedades de Superfície
5.
Braz. dent. j ; 28(5): 624-631, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888690

RESUMO

Abstract The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.


Resumo O objetivo desse estudo foi avaliar o grau de conversão, estabilidade de cor, composição química e resistência de união de um cimento resinoso fotoativado contaminado com três soluções hemostáticas diferentes. Foram preparadas amostras para o grupo controle (cimento não contaminado) e grupos experimentais (cimento contaminado com uma das soluções hemostáticas) de acordo com os testes. Para o grau de conversão e análise de cor (n=10), as amostras (3 mm de diâmetro e 2 mm de espessura) foram avaliadas por espectroscopia de infravermelho com transformação de Fourier (FTIR) e espectrofotometria CIELAB (L*, A*, B*), respectivamente. Para a análise química elementar (n=1), os espécimes (2 mm de espessura e 6 mm de diâmetro) foram avaliados por espectroscopia de energia dispersiva de raios-x (EDS). As resistências de união dos grupos foram avaliadas pelo ensaio de microcisalhamento (n=20) em um substrato cerâmico de vidro reforçado com leucita, seguida da análise de modo de falha por microscopia eletrônica de varredura (MEV). Os valores médios, com exceção da avaliação química e do modo de falha, foram avaliados por ANOVA e pelo teste de Tukey. A estabilidade de cor foi influenciada pelo tempo de armazenagem (p<0,001) e interação entre a contaminação e o tempo (p<0,001). A contaminação pelo Hemostop e Viscostat Clear não influenciaram no GC, porém a contaminação com Viscostat aumentou o GC. A resistência de união do cimento a cerâmica foi negativamente afetada pelos contaminantes (p<0,001). A contaminação por agentes hemostáticos afetou a resistência de união, o grau de conversão e a estabilidade de cor do cimento resinoso fotoativado testado.


Assuntos
Hemostáticos , Cimentos de Resina/química , Cor , Microscopia Eletrônica de Varredura , Soluções , Análise Espectral , Propriedades de Superfície
6.
J Oral Implantol ; 40(2): 123-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22251283

RESUMO

The purpose of this study was to analyze the influence of the setting and the presence of solid lubricant on the abutment screw surface on the flexural strength of the joint implant/abutment/screw. Forty abutments were connected to external hex implants, divided into 4 groups (n = 10): FE (titanium alloy screw threaded in the extremity), LE (titanium alloy screw with solid lubricant and thread in the extremity), FT (titanium alloy screw with threaded in all its length), and LT (titanium alloy screw with solid lubricant and thread in all its length). Through the mechanical flexural test, the implant/abutment resistance was evaluated with load applied perpendicular to the long axis in a mechanical testing machine (EMIC) under a speed of 0.5 mm/min. Data were submitted to a statistics test, and results showed statistically significant differences between the FE group and the other groups, and the FE group showed the lowest values. The LE group showed greater values than the LT group, and the values were statistically significant. According to the methodology used, it can be concluded that within noncoated titanium screws, a screw threaded along its entire length provided greater rigidity to the implant set, while with the screw containing solid lubricant, the screw threaded in all its length provided less rigidity of the implant set than screws with the thread only on the end. Among screws with the same geometry, those with the solid lubricant are statistically higher than those which do not have threads just at the end, but those with threads along their entire length do not show statistically significant differences.


Assuntos
Materiais Revestidos Biocompatíveis/química , Dente Suporte , Projeto do Implante Dentário-Pivô , Materiais Dentários/química , Ligas Dentárias/química , Análise do Estresse Dentário/instrumentação , Humanos , Lubrificantes/química , Maleabilidade , Estresse Mecânico , Propriedades de Superfície , Titânio/química
7.
Braz. dent. j ; 25(4): 327-331, 2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722604

RESUMO

The aim of this study was to evaluate the microtensile bond strength (µTBS) of two substrates (enamel and dentin) considering two study factors: type of composite resin [methacrylate-based (Filtek Supreme) or silorane-based (Filtek LS)] and aging time (24 h or 3 months). Twenty human molars were selected and divided into 2 groups (n=10) considering two dental substrates, enamel or dentin. The enamel and dentin of each tooth was divided into two halves separated by a glass plate. Each tooth was restored using both tested composite resins following the manufacturer's instructions. The samples were sectioned, producing 4 sticks for each composite resin. Half of them were tested after 24 h and half after 3 months. µTBS testing was carried out at 0.05 mm/s. Data were analyzed by three-way ANOVA and Tukey's HSD tests at α=0.05. Significant differences between composite resins and substrates were found (p<0.05), but no statistically significant difference was found for aging time and interactions among study factors. The methacrylate-based resin showed higher µTBS than the silorane-based resin. The µTBS for enamel was significantly higher than for dentin, irrespective of the composite resin and storage time. Three months of storage was not sufficient time to cause degradation of the bonding interaction of either of the composite resins to enamel and dentin.


O objetivo deste estudo foi avaliar a resistência adesiva por meio do teste de microtração (µTBS) entre dois substratos (esmalte e dentina) considerando dois fatores em estudo: Tipo de resina [metacrilato (Filtek Supreme) ou silorano (Filtek LS)] e tempo de envelhecimento (24 horas ou 3 meses). Vinte molares humanos foram selecionados e divididos em dois grupos (n=10) considerando dois substratos dentários, esmalte e dentina. O esmalte e a dentina de cada dente foram divididos em duas metades, por meio de uma lamínula. Cada dente foi restaurado usando ambas as resinas testadas, seguindo instruções do fabricante. As amostras foram seccionadas, resultando em quatro palitos para cada tipo de resina. Metade dos palitos foi testada após 24h e o restante após três meses. O ensaio de microtração (µTBS) foi conduzido numa velocidade de 0,05 mm/s. Os dados foram analisados usando three-way ANOVA e teste de Tukey HSD (α= 0,05). Diferença significante foi encontrada para o fator resina e substratos (p<0,05), porém não houve influência do tempo de envelhecimento e interações entre fatores estudados. A resina à base de metacrilato apresentou maior resistência adesiva do que a silorano. A adesão em esmalte foi significativamente maior do que em dentina, independente da resina e do tempo de envelhecimento. Três meses de armazenamento não foram suficientes para causar degradação da interação adesiva, para ambas as resinas compostas, no esmalte e na dentina.


Assuntos
Humanos , Esmalte Dentário , Dentina , Metacrilatos , Resinas de Silorano , Resistência à Tração , Técnicas In Vitro
8.
J Oral Implantol ; 39(4): 483-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21905897

RESUMO

The loss of gingival volume is a major challenge for dental surgeons with implant-supported fixed prosthesis manufactures, particularly from an aesthetics perspective in patients with a high smile line. Gingival tissue remodeling can help in papillae formation to avoid soft tissue surgery by reestablishing the appropriate shape and gingival contour of the tissues. This improves not only the aesthetics, but also the phonetics of the patient. This paper describes a clinical case of gingival conditioning obtained with interim implant-supported fixed partial dentures via incremental addition and adjustment of acrylic resin. The purpose of the gingival conditioning was to obtain improved aesthetics. Gingival conditioning by gradual pressure application is presented as an easy, non-traumatic technique that improves gingival aesthetics.


Assuntos
Prótese Dentária Fixada por Implante , Gengiva/anatomia & histologia , Condicionamento de Tecido Mole Oral/métodos , Resinas Acrílicas , Prótese Parcial Fixa , Feminino , Humanos , Prótese Periodontal
9.
Prosthes. Lab. Sci. ; 2(8): 357-363, jul. - set. 2013. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-853802

RESUMO

Os sistemas CAD/CAM utilizados em Odontologia Restauradora são no todo bastante versáteis. Consegue-se por meio deles obter estruturas em diferentes materiais – zircônia, Co-Cr e titânio, para serem cimentadas ou aparafusadas sobre implantes e/ou pilares de diferentes sistemas. Além disso, podem ser construídas próteses parciais (“inlays”, “onlays” e facetas) e coroas totais em diferentes cerâmicas vítreas – Feldspática, reforçadas com leucita e dissilicato de lítio. Ainda, há vários polímeros que permitem obter enceramentos, provisórios e até próteses definitivas. Entretanto, nem todos os softwares disponibilizados para os diferentes sistemas fazem todas as possibilidades, às vezes limitados pelo escâner, às vezes limitados pela fresadora (CAM). O intuito deste trabalho é ilustrar diferentes possibilidades de se obter uma coroa para um implante unitário em área posterior (molar), por meio do sistema CAD/CAM CEREC da Sirona. São mostradas e discutidas três possibilidades: por meio do Ti-base e seu corpo de escaneamento, usando a ferramenta coroa telescópica com uma estrutura de zircônia e um recobrimento em cerâmica feldspática, e construindo uma coroa de dissilicato de lítio diretamente sobre um pilar, ora moldado em um modelo, ora moldado diretamente da boca do paciente. Discutem-se as vantagens e desvantagens relativas à resistência dos materiais, estética e custo benefício dos procedimentos adotados


Assuntos
Humanos , Análise Custo-Benefício , Implantes Dentários , Implantes Dentários para Um Único Dente , Materiais Dentários , Estética , Próteses e Implantes
10.
Prosthes. Lab. Sci. ; 2(5): 48-56, 2012. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-853763

RESUMO

A prótese odontológica é conhecida desde a antiguidade. No último século, inúmeras maneiras de contruir prótese fixa de três elementos têm sido descritas: próteses metalo-plásticas, metalo-cerâmicas e mais recentemente, confeccionadas em cerâmica pura, tendo, como substrato, uma estrutura reforçada com alumina ou com zircônia. O objetivo deste trabalho é ilustrar uma nova possibilidade técnica: O processo “multi layer” por meio do software in Lab 4.0 do sistema CEREC da Sirona. O processo é novo e revoluciona por permitir a obtenção de uma prótese de três elementos em aproximadamente onze horas de trabalho, sendo destas, no máximo quatro frente ao paciente. Historicamente, a prótese odontológica é sinônima de demora e de desconforto. Confeccionadas apartir de complexos procedimentos clínicos e laboratoriais estas próteses exigem excelentes resultados relativos à adaptação e a resistência, sob o risco de terem pequena longevidade quando em uso. O Processo em questão conta com dois desenhos feitos concomitantemente pelo referido software: o da estrutura e o da cobertura estética, esta usinada em dissilicato de Lítio e aquela em Zircônia, em distintos momentos.Na sequência, a estrura de Zircônia é cromatizada e sinterizada enquanto a cobertura de dissilicato de Lítio é cristalizada e maquiada, embora sua cristalização possa ser realizada simultaneamente á fixação dessas duas partes. Finalmente, as duas partes são unidas com a cerâmica IPS e.max CAD Crystall./Connect, da ivoclar Vivadent, em temperatura para cerâmica a base de Dissilicato de Lítio. Após o resfriamento a prótese é então ajustada glazeada e fixada definitivamente.Ressalta-se que embora extremamente rápido o processo é novo e precisa ser acompanhado clinicamente, uma vez que ainda não há publicações de acompanhamento longitudinal


Assuntos
Prótese Dentária , Estética Dentária , Odontologia/métodos
11.
J. appl. oral sci ; 17(2): 140-144, Mar.-Apr. 2009. ilus
Artigo em Inglês | LILACS | ID: lil-503993

RESUMO

The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In this paper, two cases are presented, in which fractures occurred in extensive metal-ceramic fixed partial dentures, and their replacement was not possible. Ceramic repair was chosen and the sequences of treatment with and without presence of the ceramic fragment are also discussed. The cases illustrate that, in some situations, fractured metal-ceramic partial dentures can be successfully repaired when prosthetic replacement is not a choice. Prosthodontists must use alternatives that allow a reliable repair to extensive metal-ceramic fixed partial dentures. Surface preparation of the ceramic with hydrofluoric acid in conjunction with a silane coupling agent is essential for a predictable bonding of composite resin. The repair performed with composite resin is an esthetic and functional alternative when extensive fixed partial dentures cannot be replaced.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Porcelana Dentária , Prótese Parcial Fixa , Reparação em Dentadura/métodos , Condicionamento Ácido do Dente , Resinas Compostas , Colagem Dentária/métodos , Ligas Metalo-Cerâmicas , Cimentos de Resina , Silanos
12.
Braz Oral Res ; 22(1): 11-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18425239

RESUMO

Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1--soft, 2--medium and 3--hard) were as follows: (D1) 1.25 +/- 0.45; (D2) 1.12 +/- 0.44; (D3) 1.05 +/- 0.41. For enamel (E / bristle consistency: 1--soft, 2--medium and 3--hard), the initial results were: (E1) 1.18 +/- 0.35; (E2) 1.32 +/- 0.25; (E3) 1.50 +/- 0.38. After brushing, the following were the values for dentin: (D1) 2.32 +/- 1.99; (D2) 3.30 +/- 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 +/- 0.31; (E2) 2.15 +/- 0.90; (E3) 1.22 +/- 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.


Assuntos
Esmalte Dentário , Dentifrícios/efeitos adversos , Dentina , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos , Análise de Variância , Dispositivos para o Cuidado Bucal Domiciliar , Dentina/patologia , Dureza , Humanos , Colo do Dente/efeitos dos fármacos , Colo do Dente/patologia , Cremes Dentais/efeitos adversos
13.
Braz. oral res ; 22(1): 11-17, Jan.-Mar. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-480577

RESUMO

Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1 - soft, 2 - medium and 3 - hard) were as follows: (D1) 1.25 ± 0.45; (D2) 1.12 ± 0.44; (D3) 1.05 ± 0.41. For enamel (E / bristle consistency: 1 - soft, 2 - medium and 3 - hard), the initial results were: (E1) 1.18 ± 0.35; (E2) 1.32 ± 0.25; (E3) 1.50 ± 0.38. After brushing, the following were the values for dentin: (D1) 2.32 ± 1.99; (D2) 3.30 ± 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 ± 0.31; (E2) 2.15 ± 0.90; (E3) 1.22 ± 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.


Assuntos
Humanos , Esmalte Dentário , Dentina , Dentifrícios/efeitos adversos , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos , Análise de Variância , Dispositivos para o Cuidado Bucal Domiciliar , Dentina/patologia , Dureza , Colo do Dente/efeitos dos fármacos , Colo do Dente/patologia , Cremes Dentais/efeitos adversos
14.
Pesqui. bras. odontopediatria clín. integr ; 6(3): 259-266, set.-dez. 2006. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-455406

RESUMO

Objetivo: Avaliar a função mastigatória de indivíduos reabilitados com próteses totais muco-suportadas,consideradas adequadas ou boas (índice de Kapur), por meio de testes objetivos e subjetivos e verificar a influência da qualidade e do tempo de uso das próteses. Método: Testes de performance mastigatória (PM), utilizando o simulador dealimento Optocal, foram realizados com 20 e 40 golpes mastigatórios em 21 indivíduos com próteses totais (grupo PT) e 15 com dentição natural (grupo DN). O índice de performance mastigatória foi obtido por meio do cálculo do Diâmetro Geométrico Médio das partículas mastigadas e tamisadas. Resultados: Após análise estatística (Tukey b, p<0,05), observou-se que o grupo PT apresentou 12 por cento e 31 por cento da performance alcançada pelos indivíduos do grupo DN, após 20e 40 golpes, respectivamente, sendo que a literatura quantifica a mesma de 20 por cento a 30 por cento da dentição natural. Não foram verificadas diferenças estatisticamente significantes (Teste-tde student, p<0,05) entre a PM e a habilidade mastigatória, bem como à qualidade das próteses do grupo PT. Em relação ao tempo de uso das próteses, usuários acima de seis meses obtiveram melhores resultados, possivelmente por estarem mais adaptados às próteses. Conclusão: No limite deste trabalho, podemos concluir que usuários de próteses totais consideradas adequadas ou boas melhoraram sua PM após seis meses de uso. Ressaltando que com 20 golpes, no referido simulador de alimento, o resultado (12 por cento) foi inferior aos descritos na literatura.


Assuntos
Humanos , Masculino , Feminino , Idoso , Dentição , Mastigação , Prótese Total , Interpretação Estatística de Dados
15.
RBP Rev. bras. implantodont. protese implant ; 10(37): 9-17, jan.-mar. 2003. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-366045

RESUMO

Frente ao sucesso dos implantes osseointegrados, sua utilização para os mais diversos tipos de pacientes desdentados revolucionou a reabilitação oral. Especificamente para os arcos desdentados totais superiores, a complexidade do tratamento tem provocado estudos sobre a necessidade de enxertos gengivais e/ou ósseos, além do número, distribuição, inclinação, posicionamento, comprimento e diâmetro dos implantes. Tudo isto em função das condições gerais de saúde, da presença de hábitos parafuncionais, da expectativa do paciente quanto a função e estética. Potenciais fatores de insucesso devem ser previamente identificados, contornados ou esclarecidos, evitando futuras decepções. Sabe-se, entretanto, que a incompatibilidade da linha e/ou suporte labial com a deficiência óssea apresentada pelo paciente e com a expectativa estética do mesmo tem gerado conflitos entre profissional e cliente, ao final do tratamento. Objetivando otimizar a relação paciente-profissional previamente ao início do caso, possibilitando a visualização, por parte do paciente, de possíveis dificuldades estéticas, o presente trabalho sugere a utilização de um guia de estudo radiológico em resina acrílica, para determinar a influência estética da linha labial e/ou do suporte labial. Reconhecendo as limitações inerentes ao caso, o próprio paciente devidamente informado pode eleger a forma de tratamento mais conveniente.


Assuntos
Protocolos Clínicos , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Prótese Parcial Removível
16.
ROBRAC ; 11(31): 22-6, jun. 2002. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-872448

RESUMO

Nos últimos anos, a implantodontia se firmou como uma realidade graça à previsibilidade e à longevidade dos tratamentos. Entretanto, a inclinação e o posicionamento do implante em relação ao tecido gengival, além das limitações de espaços interoclusais, são aspectos clínicos que, às vezes, dificultavam e até impossibilitavam a confecção de próteses, ora por motivo estético, ora por motivos mecânicos. Novos componentes foram desenvolvidos em função de tais necessidades práticas, visando melhor estética e/ou maior resistência, surgindo assim uma gama de pilares trans-epiteliais com o objetivo de facilitar a resolução de problemas clínicos. O recente desenvolvimento de novos componentes preparáveis iniciou uma polêmcia: parafusar ou cimentar as próteses implantadas? A vantagem da reversibilidade e a facilidade de reparo das parafusadas contra os procedimentos clínicos rotineiros necessários para as cimentadas. Cimentar ou parafusar a prótese pode ser uma complexa decisão ou uma única estratégia


Assuntos
Prótese Dentária , Implantes Dentários , Osseointegração
17.
PCL ; 4(17): 8-16, jan.-fev. 2002. ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853274

RESUMO

Neste trabalho, os autores descrevem a técnica de confecção das overlays, abordando a importância desses aparelhos na reabilitação de pacientes com redução na dimensão vertical de oclusão


Assuntos
Prótese Parcial Temporária , Dimensão Vertical , Reabilitação Bucal/métodos
18.
PCL ; 3(14): 336-42, jul.-ago. 2001. ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853250

RESUMO

Os autores apresentam a técnica de utilização de dentes naturais do próprio paciente na confecção de prótese removível total, enfatizando suas vantagens e desvantagens. Três casos clínicos sob controle há 65 meses, 53 meses e 24 meses são apresentados para evidenciar a viabilidade clínica e técnica deste procedimento. Neste período ocorreu deslocamento de apenas um dente, mas sem qualquer fratura e/ou cárie nos dentes utilizados


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Prótese Total , Prótese Parcial Removível , Estética Dentária
19.
PCL ; 3(12): 147-54, mar.-abr. 2001. ilus, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853237

RESUMO

Os autores propõem uma nova técnica para a confecção de reforço metálico para prótese removível total tipo overdenture. A estrutura metálica é confeccionada sobre o modelo funcional e incorporada à base acrílica da prótese durante a inclusão e prensagem da resina acrílica ativada termicamente. Tal procedimento é de fácil execução, baixo custo e proporciona maior confiança e segurança ao usuário da prótese


Assuntos
Ligas de Cromo , Modelos Dentários , Bases de Dentadura , Prótese Total , Materiais Dentários , Retenção em Prótese Dentária , Fraturas dos Dentes/prevenção & controle
20.
ROBRAC ; 9(28): 45-7, dez. 2000. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-298194

RESUMO

A técnica de confecçäo de uma prótese parcial removível, usando os dentes naturais do próprio paciente é descrita neste trabalho. O resultado estético e funcional alcançado foi bastante satisfatório, o que encoraja o emprego da técnica em pacientes que perdem os dentes por doença periodontal ou por acidentes. Durante o período de controle (dois anos) nenhuma fratura, deslocamento ou cáries foram detectados nos dentes naturais


Assuntos
Prótese Parcial Removível , Estética Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...