Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 854: 145-52, 2015 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-25479878

RESUMO

H2O2 is a widely occurring molecule which is also a byproduct of a number of enzymatic reactions. It can therefore be used to quantify the corresponding enzymatic substrates. In this study, the time-resolved fluorescence emission of a previously described complex consisting of phthalic acid and terbium (III) ions (PATb) is used for H2O2 detection. In detail, glucose oxidase and choline oxidase convert glucose and choline, respectively, to generate H2O2 which acts as a quencher for the PATb complex. The response time of the PATb complex toward H2O2 is immediate and the assay time only depends on the conversion rate of the enzymes involved. The PATb assay quantifies glucose in a linear range of 0.02-10 mmol L(-1), and choline from 1.56 to 100 µmol L(-1) with a detection limit of 20 µmol L(-1) for glucose and 1.56 µmol L(-1) for choline. Both biomolecules glucose and choline could be detected without pretreatment with good precision and reproducibility in human serum samples and infant formula, respectively. Furthermore, it is shown that the detected glucose concentrations by the PATb system agree with the results of a commercially available assay. In principle, the PATb system is a universal and versatile tool for the quantification of any substrate and enzyme reaction where H2O2 is involved.


Assuntos
Peróxido de Hidrogênio/metabolismo , Glicemia/análise , Colina/análise , Humanos , Alimentos Infantis/análise , Especificidade por Substrato
2.
BMC Biotechnol ; 14: 88, 2014 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-25326050

RESUMO

BACKGROUND: Protein cross-coupling reactions demand high yields, especially if the products are intended for bioanalytics, like enzyme-linked immunosorbent assays. Amongst other factors, the coupling yield depends on the concentration of the proteins being used for coupling. Protein supercharging of enzymes can increase the solubility dramatically, which could promote enzyme-antibody coupling reactions. A highly soluble, supercharged variant of the enzyme human enteropeptidase light chain was created by a site-directed mutagenesis of surface amino acids, used for the production of an antibody-enzyme conjugate and compared to the wild type enzyme. RESULTS: Wild type and mutant enzyme could successfully be cross-coupled to an antibody to give antibody-enzyme conjugates suitable for ELISA. Their assay performances and the analysis of the enzyme activities in solution demonstrate that the supercharged version could be coupled to a higher extent, which resulted in better assay sensitivities. The generated conjugate, based on the supercharged enzyme, was feasible as a reporter molecule in a sandwich ELISA and allowed the detection of epidermal growth factor with a detection limit of 15.63 pg (25 pmol/L). CONCLUSION: The highly soluble, surface supercharged, human enteropeptidase light chain mutant provided better yields in coupling the enzyme to an antibody than the wild type. This is most likely related to the higher protein concentration during the coupling. The data suggest that supercharging can be applied favourably to other proteins which have to be covalently linked to other polymers or surfaces with high yields without losses in enzyme activity or specificity.


Assuntos
Anticorpos/química , Enteropeptidase/química , Enteropeptidase/genética , Enteropeptidase/metabolismo , Ensaio de Imunoadsorção Enzimática , Humanos , Mutagênese Sítio-Dirigida
3.
Sci Rep ; 4: 5613, 2014 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-25000910

RESUMO

Here, we present a fast mix-and-measure immunoassay for the specific semiquantitative detection of His-tagged proteins, for example in E. coli cell lysate. The assay is based on Förster resonance energy transfer (FRET) between a lanthanide dye-labeled low-affinity His-peptide and an acceptor-labeled anti-His-tag antibody. The targeted His-tag protein in the sample displaces the donor-labeled peptide and leads to a concentration-dependent time-resolved fluorescence signal. The assay has a total assay time of less than two minutes including sample preparation. The assay recognizes both, N- and C-terminally tagged proteins. The detection limit is comparable to those obtained in SDS-PAGE or Western Blot, which are used as standard methods for the characterization of His-tag protein expression. Additionally, we demonstrate a full compatibility of the developed assay to cell lysate, and a correlation to detectable bands in a western blot application. In conclusion, this fast, sensitive, specific and affordable mix-and-measure assay provides a timesaving and user-friendly way to quantify recombinant protein expression. It substantially reduces the workload for recombinant protein detection, especially when His-tag-protein-containing fractions in manual chromatographic purifications have to be identified.


Assuntos
Transferência Ressonante de Energia de Fluorescência/métodos , Histidina/análise , Histidina/imunologia , Imunoensaio/métodos , Proteínas Recombinantes/análise , Proteínas Recombinantes/imunologia , Escherichia coli/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Anal Chim Acta ; 834: 51-7, 2014 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-24928245

RESUMO

Here, we present a fast and simple hydrogen peroxide assay that is based on time-resolved fluorescence. The emission intensity of a complex consisting of terbium ions (Tb(3+)) and phthalic acid (PA) in HEPES buffer is quenched in the presence of H2O2 and this quenching is concentration-dependent. The novel PATb assay detects hydrogen peroxide at a pH range from 7.5 to 8.5 and with a detection limit of 150 nmol L(-1) at pH 8.5. The total assay time is less than 1 min. The linear range of the assay can be adapted by a pH adjustment of the aqueous buffer and covers a concentration range from 310 nmol L(-1) to 2.56 mmol L(-1) in total which encompasses four orders of magnitude. The assay is compatible with high concentrations of all 47 tested inorganic and organic compounds. The PATb assay was applied to quantify H2O2 in polluted river water samples. In conclusion, this fast and easy-to-use assay detects H2O2 with high sensitivity and precision.


Assuntos
Peróxido de Hidrogênio/análise , Substâncias Luminescentes/química , Ácidos Ftálicos/química , Térbio/química , Poluentes Químicos da Água/análise , Cátions/química , Limite de Detecção , Luminescência , Medições Luminescentes/métodos , Rios/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...