Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 16(8)2016 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-27527178

RESUMO

Optical feedback interferometry (OFI) is a compact sensing technique with recent implementation for flow measurements in microchannels. We propose implementing OFI for the analysis at the microscale of multiphase flows starting with the case of parallel flows of two immiscible fluids. The velocity profiles in each phase were measured and the interface location estimated for several operating conditions. To the authors knowledge, this sensing technique is applied here for the first time to multiphase flows. Theoretical profiles issued from a model based on the Couette viscous flow approximation reproduce fairly well the experimental results. The sensing system and the analysis presented here provide a new tool for studying more complex interactions between immiscible fluids (such as liquid droplets flowing in a microchannel).

2.
Bioresour Technol ; 102(12): 6702-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21514822

RESUMO

Many analytical procedures have been developed to determine the composition of reaction mixtures during transesterification of vegetable oils with alcohols. However, despite their accuracy, these methods are time consuming and cannot be easily used for on-line monitoring. In this work, a fast analytical method was developed to on-line monitor the transesterification reaction of high oleic sunflower oil with ethanol using Near InfraRed spectroscopy and a multivariate approach. The reactions were monitored through sequential scans of the reaction medium with a probe in a one-liter batch reactor without collecting and preparing samples. To calibrate the NIR analytical method, gas chromatography-flame ionization detection was used as a reference method. The method was validated by studying the kinetics of the EtONa-catalyzed transesterification reaction. Activation energy (51.0 kJ/mol) was also determined by considering a pseudo second order kinetics model.


Assuntos
Biocombustíveis , Etanol/química , Óleos de Plantas/química , Espectrofotometria Infravermelho/métodos , Triglicerídeos/química , Cromatografia Gasosa , Esterificação , Cinética , Modelos Químicos , Análise Multivariada , Óleo de Girassol
3.
Lab Chip ; 11(5): 779-87, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21157611

RESUMO

This mini-review focuses on two different miniaturizing approaches: the first one describes the generation and use of droplets flowing within a millifluidic tool as individual batch microreactors. The second one reports the use of high pressure microflows in chemistry. Millifluidics is an inexpensive, versatile and easy to use approach which is upscaled from microfluidics. It enables one to produce hierarchically organized multiple emulsions or particles with a good control over sizes and shapes, as well as to provide a convenient data acquisition platform dedicated to slow or rather fast chemical reactions, i.e., from hours to a few minutes. High-pressure resistant devices were recently fabricated and used to generate stable droplets from pressurized fluids such as supercritical fluid-liquid systems. We believe that supercritical microfluidics is a promising tool to develop sustainable processes in chemistry.

4.
Lab Chip ; 9(20): 3007-11, 2009 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-19789758

RESUMO

An easy assembling-disassembling co-axial capillaries microfluidic device was built up for the production of double droplets. Uniform polymer core-polymer shell particles were synthesized by polymerizing the two immiscible monomer phases composing the double droplet. Thus poly(acrylamide) core-poly(tri(propylene glycol) diacrylate) shell particles with controlled core diameter and shell thickness were simply obtained by adjusting operating parameters. An empirical law was extracted from experiments to predict core and shell sizes. Additionally uniform and predictable non-spherical polymer objects were also prepared without adding shape-formation procedures in the experimental device. An empirical equation for describing the lengths of rod-like polymer particles is also presented.

5.
Langmuir ; 23(14): 7745-50, 2007 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-17530868

RESUMO

Monodisperse and size-controlled spherical polymer particles were synthesized by in situ photopolymerization of O/W monomer emulsions. Monomer droplets were produced without surfactant or pretreatment at a needle tip in a simplified axisymmetric microfluidic device. The effect of the viscosity of the continuous phase on the particle size was studied. The system operated in the dripping mode, at a low Reynolds number. A dimensionless master curve describes the particle diameter as a function of the needle inner diameter as well as velocity and viscosity ratios of continuous and dispersed phases. An empirical law predicts the particle size. The normalized particle diameter depends upon the ratio of the capillary numbers of continuous and dispersed phases with an exponent equal to -0.22.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...