Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743410

RESUMO

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Assuntos
Computadores de Mão , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Criança , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Testes de Campo Visual/instrumentação , Masculino , Feminino , Adolescente , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Reprodutibilidade dos Testes
2.
J Clin Med ; 12(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37048613

RESUMO

BACKGROUND: To determine the 12-month compliance with and retention of home monitoring (HM) with Melbourne Rapid Fields (MRFh) for patients with intermediate age-related macular degeneration (iAMD) and compare visual acuity (VA) and retinal sensitivity (RS) results to clinical measures. METHODS: Participants were recruited to a 12-month HM study with weekly testing of vision with MRFh. Inclusion criteria were a diagnosis of iAMD, understand English instructions, VA ≥ 20/40, and access to an iPad. Supervised in-clinic testing of high contrast VA (HVA, ETDRS), low-luminance VA (LLVA, ETDRS with ND2 filter), and RS (Macular Integrity Assessment, MAIA, and MRF in-clinic, MRFc) was conducted every 6-months. RESULTS: A total of 54 participants (67 ± 6.8 years) were enrolled. Compliance to weekly HM was 61% and study retention at 12-months was 50% of those with uptake (n = 46). No difference was observed between MRFc and MRFh across all RS and VA outcomes (p > 0.05). MRFh RS was higher than MAIA (29.1 vs. 27.1 dB, p < 0.001). MRFh HVA was not different from ETDRS (p = 0.08), but LLVA was 9 letters better (81.5 vs. 72.4 letters, p < 0.001). CONCLUSIONS: Over 12-months, MRFh yields a moderate level of compliance with (61%) and retention (50%) of weekly testing. Further studies are required to assess the ability of MRFh to detect early progression to nAMD.

3.
J Clin Med ; 11(15)2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35893408

RESUMO

Background: Our primary aim is to quantify test reliability and compliance of glaucoma patients to a weekly visual field telemedicine (VFTM) schedule. A secondary aim is to determine concordance of the VFTM results to in-clinic outcomes. Methods: Participants with stable glaucoma in one eye were recruited for a 12 month VFTM trial using the Melbourne Rapid Fields (MRF-home, MRFh) iPad application. Participants attended routine 6 month clinical reviews and were tasked with weekly home monitoring with the MRFh over this period. We determined compliance to weekly VFTM (7 + 1 days) and test reliability (false positives (FPs) and fixation loss (FL) <33%). A secondary aim considered concordance to in-clinic measures of visual field (MRF-clinic (MRFc) and the Humphrey Field Analyzer (HFA)) in active participants (≥10 home examinations and 5 reliable HFA examinations). The linear trend in the MRFh mean deviation (MD) was compared to the HFA guided progression analysis (GPA) using Bland−Altman methods. Data are shown as the mean ± standard deviation. Results: Forty-seven participants with a mean age of 64 ± 14.6 years were recruited for the trial. The VFTM uptake was 85% and compliance to weekly home monitoring was 75% in the presence of weekly text reminders in the analysed group (n = 20). The analysed group was composed of test subjects with five reliable in-clinic HFA examinations (GPA analysis available) and who submitted a minimum of 10 MRFh examinations from home. Of the 757 home examinations returned, approximately two-thirds were reliable, which was significantly lower than the test reliability of the HFA in-clinic (MRFh: 65% vs. HFA: 85%, p < 0.001). The HFA-GPA analysis gave little bias from the MRFh slope (bias: 0.05 dB/yr, p > 0.05). Two eyes were found to have clinical progression during the 12 month period, and both were detected by VFTM. Conclusions: VFTM over 12 months returned good compliance (75%) to weekly testing with good concordance to in-clinic assays. VFTM is a viable option for monitoring patients with glaucoma for visual field progression in between clinical visits.

4.
Am J Ophthalmol ; 235: 280-290, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34509437

RESUMO

PURPOSE: The aim of this study was to determine the short-term compliance with regular home monitoring of macular retinal sensitivity (RS) in intermediate age-related macular degeneration (iAMD). Home-based outcomes were compared with in-clinic outcomes determined using (1) the same tablet device under supervision, and (2) the Macular Integrity Assessment (MaIA) microperimeter. DESIGN: Single-center longitudinal compliance and reliability study. METHODS: A total of 73 participants with iAMD were trained to perform macular field testing with the Melbourne Rapid Fields-macular (MRF-m) iPad application. Volunteers were asked to return 6 weekly tests from home, guided by audio instructions. We determined compliance with weekly testing and surveyed for factors that limited compliance. Test reliability (false positive, false negative) and RS were compared to in-clinic assays (MaIA). Data are given as mean ± SD or as median [quartile 1-3 range]. Group comparisons were achieved with bootstrap to define the 95% confidence limits. RESULTS: A total of 59 participants submitted 6 home examinations with a median intertest interval of 8.0 [7.0-17] days. Compliance with weekly testing (7 days ±24 hours) was 55%. The main barrier to compliance was information technology (IT) logistic reasons. Of 694 home examinations submitted, 96% were reliable (false-positive results <25%). The mean RS returned by the tablet was significantly higher (+3.2 dB, P < .05) compared to the MaIA. CONCLUSIONS: Home monitoring produces reliable results that differ from in-clinic tests because of test design. This should not affect self-monitoring once an at-home baseline is established, but these differences will affect comparisons with in-clinic outcomes. Reasonable compliance with weekly testing was achieved. Improved IT support might lead to better compliance.


Assuntos
Degeneração Macular , Testes de Campo Visual , Humanos , Degeneração Macular/diagnóstico , Reprodutibilidade dos Testes , Retina , Testes de Campo Visual/métodos
5.
J Vis ; 21(11): 2, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34617957

RESUMO

The conventional stimulus for standard automated perimetry is fixed in size, giving elevated contrast thresholds and reduced test reliability in the periphery. Here, we test the hypothesis that appropriate scaling of the size of perimetric stimuli will return fixed thresholds and reduced variability across the visual field. We derived frequency-of-seeing (FOS) curves in five healthy subjects at central (3 degrees) and peripheral (27 degrees) locations with a method of constant stimuli (MOCS) using a desktop LCD display. FOS curves for a Goldmann III (GIII) stimulus were compared with those for size scaled spots. To consider clinical translation, we tested a further five healthy subjects (22-24 years) with the Melbourne Rapid Fields (MRF) tablet perimeter at several locations spanning 1 degree to 25 degrees from fixation, deriving FOS curves (MOCS) and also conducting repeated adaptive clinical thresholding to assess intra- and interobserver variability. We found that GIII contrast thresholds were significantly elevated in the periphery compared with the parafovea, with concomitant reduction of FOS slope. Using appropriately size scaled spots, threshold and slope differences between these locations were significantly reduced. FOS data collected with the tablet perimeter confirmed that size scaling confers broad equivalence of the shape of the FOS curve across the visual field. Repeated adaptive thresholding with size scaled stimuli gave relatively constant intra-observer variability across the visual field, which compares favorably with published normative data obtained with the GIII stimulus. The reduced variability will improve signal-to-noise ratio for correct classification of normal visual field test results, whereas the lower contrast thresholds yield greater dynamic range, which should improve the ability to reliably monitor moderate defects.


Assuntos
Testes de Campo Visual , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Limiar Sensorial , Razão Sinal-Ruído
6.
Am J Ophthalmol ; 223: 286-295, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33221287

RESUMO

PURPOSE: This study examines the short-term uptake, compliance, and performance of a tablet device used for home monitoring of visual field (VF-Home) by glaucoma patients. DESIGN: Single-center, observational, longitudinal, compliance study. METHODS: Participants who were glaucoma suspects or had stable glaucoma in at least one eye were recruited during a regular clinic review. Baseline in-clinic visual field (VF) was recorded with the Humphrey Field Analyser (HFA, SITA standard) and repeated at 6 months. Participants were tasked with performing 6 VF examinations from home, at weekly intervals, using a loaned iPad tablet. Uptake was defined as returning at least 1 test from home. Reliability and global indices from VF-Home were compared to in-clinic outcomes. Data are shown as either mean ± [standard deviation] or median [quartile 1-3 range], and group comparisons were achieved with bootstrap. RESULTS: We recruited 186 eyes of 101 participants. VF-Home uptake was excellent, with 88% of participants successfully completing ≥1 home examination and 69% completing all 6 examinations. The median duration between tests was 7.0 [7.0-8.0] days. Barriers to uptake and compliance involved information technology (IT) logistical reasons, lack of motivation, or competing life demands. VF-Home gave greater fixation loss but a similar level of False Positives (FP) as the HFA. A high correlation was found for the mean defect between in-clinic and at-home outcomes (R = 0.85). CONCLUSIONS: VF-Home can return a high level of short-term compliance and results comparable to those found by in-clinic testing. IT logistical reasons and lack of motivation are barriers to uptake and compliance.


Assuntos
Algoritmos , Glaucoma/diagnóstico , Monitorização Fisiológica/métodos , Cooperação do Paciente , Campos Visuais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Testes de Campo Visual/métodos , Adulto Jovem
7.
Am J Ophthalmol ; 190: 9-16, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29550190

RESUMO

PURPOSE: To establish the medium-term repeatability of the iPad perimetry app Melbourne Rapid Fields (MRF) compared to Humphrey Field Analyzer (HFA) 24-2 SITA-standard and SITA-fast programs. DESIGN: Multicenter longitudinal observational clinical study. METHODS: Sixty patients (stable glaucoma/ocular hypertension/glaucoma suspects) were recruited into a 6-month longitudinal clinical study with visits planned at baseline and at 2, 4, and 6 months. At each visit patients undertook visual field assessment using the MRF perimetry application and either HFA SITA-fast (n = 21) or SITA-standard (n = 39). The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests. Secondary measures were the point-wise threshold and repeatability for each test, as well as test time. RESULTS: MRF was similar to SITA-fast in speed and significantly faster than SITA-standard (MRF 4.6 ± 0.1 minutes vs SITA-fast 4.3 ± 0.2 minutes vs SITA-standard 6.2 ± 0.1 minutes, P < .001). Intraclass correlation coefficients (ICC) between MRF and SITA-fast for MD at the 4 visits ranged from 0.71 to 0.88. ICC values between MRF and SITA-standard for MD ranged from 0.81 to 0.90. Repeatability of MRF MD outcomes was excellent, with ICC for baseline and the 6-month visit being 0.98 (95% confidence interval: 0.96-0.99). In comparison, ICC at 6-month retest for SITA-fast was 0.95 and SITA-standard 0.93. Fewer points changed with the MRF, although for those that did, the MRF gave greater point-wise variability than did the SITA tests. CONCLUSIONS: MRF correlated strongly with HFA across 4 visits over a 6-month period, and has good test-retest reliability. MRF is suitable for monitoring visual fields in settings where conventional perimetry is not readily accessible.


Assuntos
Computadores de Mão , Glaucoma de Ângulo Aberto/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/instrumentação , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Transtornos da Visão/fisiopatologia , Adulto Jovem
8.
Angiogenesis ; 21(1): 95-109, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29318471

RESUMO

Ocular neovascularization is a common pathological feature in diabetic retinopathy and neovascular age-related macular degeneration that can lead to severe vision loss. We evaluated the therapeutic efficacy of a novel endogenous inhibitor of angiogenesis, the calreticulin anti-angiogenic domain (CAD180), and its functional 112-residue fragment, CAD-like peptide 112 (CAD112), delivered using a self-complementary adeno-associated virus serotype 2 (scAAV2) in rodent models of oxygen-induced retinopathy and laser-induced choroidal neovascularization. The expression of CAD180 and CAD112 was elevated in human umbilical vein endothelial cells transduced with scAAV2-CAD180 or scAAV2-CAD112, respectively, and both inhibited angiogenic activity in vitro. Intravitreal gene delivery of scAAV2-CAD180 or scAAV2-CAD112 significantly inhibited ischemia-induced retinal neovascularization in rat eyes (CAD180: 52.7% reduction; CAD112: 49.2% reduction) compared to scAAV2-mCherry, as measured in retinal flatmounts stained with isolectin B4. Moreover, the retinal structure and function were unaffected by scAAV2-CAD180 or scAAV2-CAD112, as measured by optical coherence tomography and electroretinography. Moreover, subretinal delivery of scAAV2-CAD180 or scAAV2-CAD112 significantly attenuated laser-induced choroidal neovascularization in mouse eyes compared to scAAV2-mCherry, as measured by fundus fluorescein angiography (CAD180: 62.4% reduction; CAD112: 57.5% reduction) and choroidal flatmounts (CAD180: 40.21% reduction; CAD112: 43.03% reduction). Gene delivery using scAAV2-CAD180 or scAAV2-CAD112 has significant potential as a therapeutic option for the management of ocular neovascularization.


Assuntos
Inibidores da Angiogênese/biossíntese , Calreticulina , Dependovirus , Retinopatia Diabética , Neovascularização Retiniana , Transdução Genética , Inibidores da Angiogênese/genética , Angiografia , Animais , Calreticulina/biossíntese , Calreticulina/genética , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/genética , Retinopatia Diabética/metabolismo , Retinopatia Diabética/fisiopatologia , Eletrorretinografia , Feminino , Vetores Genéticos , Células HEK293 , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/patologia , Humanos , Proteínas Luminescentes/biossíntese , Proteínas Luminescentes/genética , Degeneração Macular/diagnóstico por imagem , Degeneração Macular/genética , Degeneração Macular/metabolismo , Degeneração Macular/fisiopatologia , Camundongos , Ratos , Ratos Sprague-Dawley , Neovascularização Retiniana/diagnóstico por imagem , Neovascularização Retiniana/genética , Neovascularização Retiniana/metabolismo , Neovascularização Retiniana/fisiopatologia , Tomografia de Coerência Óptica , Proteína Vermelha Fluorescente
9.
Hum Gene Ther ; 28(5): 403-414, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28363247

RESUMO

Choroidal neovascularization (CNV) is a common pathological feature in neovascular age-related macular degeneration, which is the leading cause of vision loss among elderly populations in developed countries. This study evaluated the effect of a novel endogenous inhibitor of angiogenesis, calreticulin anti-angiogenic domain (CAD), subconjunctivally delivered by an adenoviral vector (Ad-CAD) in a rat model of laser-induced CNV. CAD was expressed in Ad-CAD-infected cells and inhibited the angiogenic activity in human umbilical vein endothelial cells in vitro. CAD expression was also found in various ocular tissues after in vivo subconjunctival Ad-CAD injection. Via bioluminescence imaging it is shown that a single subconjunctival injection of Ad-luciferase induced the expression of the transgene in the injected eyes within 24 h, which lasted for at least 112 days. Forty-two days after subconjunctival injection of Ad-CAD, retinal structure and function were unaffected, as measured using optical coherence tomography and electroretinography, respectively. After laser injury, subconjunctival Ad-CAD gene delivery significantly inhibited CNV lesions as measured via choroid flat-mounts (51% reduction at 21 days; p < 0.001), as well as by fundus fluorescein angiography (19.3%, 28.2%, 31%, and 27.5% reductions at days 21, 28, 35, and 42, respectively; p < 0.05) in rats. The data suggest that subconjunctival Ad-CAD gene therapy could effectively inhibit laser-induced CNV and might be an attractive therapeutic approach for the management of choroidal neovascularization.


Assuntos
Calreticulina/genética , Neovascularização de Coroide/terapia , Técnicas de Transferência de Genes , Degeneração Macular Exsudativa/terapia , Animais , Calreticulina/uso terapêutico , Neovascularização de Coroide/genética , Modelos Animais de Doenças , Terapia Genética , Vetores Genéticos/uso terapêutico , Células Endoteliais da Veia Umbilical Humana , Humanos , Ratos , Retina/efeitos dos fármacos , Retina/patologia , Degeneração Macular Exsudativa/genética , Degeneração Macular Exsudativa/patologia
10.
J Ophthalmol ; 2015: 201726, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25821585

RESUMO

Age-related macular degeneration (AMD) is the leading cause of substantial and irreversible vision loss amongst elderly populations in industrialized countries. The advanced neovascular (or "wet") form of the disease is responsible for severe and aggressive loss of central vision. Current treatments aim to seal off leaky blood vessels via laser therapy or to suppress vessel leakage and neovascular growth through intraocular injections of antibodies that target vascular endothelial growth factor (VEGF). However, the long-term success of anti-VEGF therapy can be hampered by limitations such as low or variable efficacy, high frequency of administration (usually monthly), potentially serious side effects, and, most importantly, loss of efficacy with prolonged treatment. Gene transfer of endogenous antiangiogenic proteins is an alternative approach that has the potential to provide long-term suppression of neovascularization and/or excessive vascular leakage in the eye. Preclinical studies of gene transfer in a large animal model have provided impressive preliminary results with a number of transgenes. In addition, a clinical trial in patients suffering from advanced neovascular AMD has provided proof-of-concept for successful gene transfer. In this mini review, we summarize current theories pertaining to the application of gene therapy for neovascular AMD and the potential benefits when used in conjunction with endogenous antiangiogenic proteins.