Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(19)2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37837109

RESUMO

Recent developments in networked and smart sensors have significantly changed the way Structural Health Monitoring (SHM) and asset management are being carried out. Since the sensor networks continuously provide real-time data from the structure being monitored, they constitute a more realistic image of the actual status of the structure where the maintenance or repair work can be scheduled based on real requirements. This review is aimed at providing a wealth of knowledge from the working principles of sensors commonly used in SHM, to artificial-intelligence-based digital twin systems used in SHM and proposes a new asset management framework. The way this paper is structured suits researchers and practicing experts both in the fields of sensors as well as in asset management equally.

2.
Biosens Bioelectron ; 23(1): 107-13, 2007 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-17475472

RESUMO

A novel amperometric biosensor based on polypyrrole (PPy) nanotube array deposited on a Pt plated nano-porous alumina substrate and its performances are described. Glucose oxidase (GOx) enzyme was selected as the model enzyme in this study. Commercially available nano-porous alumina discs were used to fabricate electrodes in order to study the feasibility of enzyme entrapment by physical adsorption. A PPy/PF6- film comprising of nanotube array was synthesized using a solution containing 0.05 M Pyrrole and 0.1 M NaPF6 at a current density of 0.3 mA/cm2 for 90 s. The immobilization was done by physical adsorption of 5 microL of GOx (from a stock solution of 2 mg/mL of 210 U/mg) on each electrode. A sensitivity of 7.4 mA cm(-2) M(-1) was observed with PPy nanotube array where the maximum tube diameter was 100 nm. A linear range of 500 microM-13 mM and a response time of about 3 s were observed with a nanotube array where the maximum tube diameter was 200 nm. The synthesized nanotube arrays were characterized by galvanostatic electrochemical technique. Calculated value of apparent Michaelis-Menten constant (Km) was 7.01 mM. The use of nano-porous template electrodes leads to an efficient enzyme loading and provides an increased surface area for sensing the reaction. These factors contribute to increase the characteristic performances of the novel biosensor.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Glucose Oxidase/química , Glucose/análise , Nanotubos/química , Polímeros/química , Pirróis/química , Adsorção , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Nanotubos/ultraestrutura , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...