1.
Epilepsia Open ; 8(4): 1503-1511, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37750050

RESUMO

OBJECTIVE: Single-photon emission computed tomography (SPECT) with the tracer 99m Tc-HMPAO is a method to visualize the cerebral hyperperfusion during an epileptic seizure and thus localize the epileptogenic zone and seizure propagation. Subtraction of interictal from Ictal SPECT Co-registered to MRI (SISCOM) visualizes areas with relative increases in cerebral blood flow. The purpose of this retrospective study is to explore the added value of visualizing areas of hypoperfusion as well as hyperperfusion, so-called reversed SISCOM. METHODS: Fifty-six patients operated for epilepsy who had been investigated with SISCOM were included in the analysis. The patients were divided into two groups based on seizure duration after tracer injection, above or below 30 s. The preoperative SISCOM description was compared to the area of resection and given a concordance score. The 56 SISCOM were recalculated visualizing also areas of hypoperfusion and again compared to the site of resection using the same scale of concordance. The reversed SISCOM were categorized into three subgroups: "Altered Conclusion," "Confirmed Conclusion," and "Adds Nothing." If an area of hyperperfusion had an area of hypoperfusion in close proximity, it was re-interpreted as noise, thus possibly altering the conclusion. If the areas of hypoperfusion were in the opposite hemisphere it was interpreted as confirming factor. Further the concordance scores from conventional SISCOM and reversed SISCOM was compared to surgical outcome to explore the difference in sensitivity, positive predictive value (PPV), and odds ratio. RESULTS: In approximately half of the cases reversed SISCOM added additional value, meaning either altered the conclusion or confirmed the conclusion. The sensitivity, PPV, and odds ratio was also better in the subgroup of long, >30 s seizure duration after injection, and got worse in the group with short, <30 s seizure duration after injection. SIGNIFICANCE: Adding reversed SISCOM performed better than conventional SISCOM at predicting good surgical outcome.


Assuntos
Epilepsia , Humanos , Estudos Retrospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Exametazima , Convulsões/diagnóstico por imagem , Convulsões/cirurgia
2.
Epilepsia Open ; 8(3): 1064-1074, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37464953

RESUMO

OBJECTIVE: This retrospective study investigates the predictive value of ictal subtraction single-photon emission computed tomography (SPECT) co-registered to magnetic resonance imaging (MRI) (SISCOM) for successful epilepsy surgery. METHODS: 57 patients examined with SISCOM as a part of epilepsy surgery evaluation were divided into two groups based on seizure duration after tracer injection (group 1: Seizure duration above or equal to 30 s, group 2: Seizure duration under 30 s). SISCOM was compared to the surgical site and categorized as good or poor concordance. Subsequently, Odds ratios (ORs) and positive predictive values (PPVs) were calculated for each group for good surgical outcome, freedom from disabling seizures. RESULTS: The PPVs and ORs for good surgical outcome was 74.1% and 5.71 for group 1 and 40% and 0.22 for group 2. SISCOM had a similar positive predictive value regardless of whether the focus was in the same or neighboring lobe, but same hemisphere as the resection. CONCLUSION: In conclusion, the implementation of a precise definition for a well-executed ictal SPECT scan with respect to seizure duration after injection enhances the positive predictive value (PPV) and odds ratio (OR) for successful surgical outcome, surpassing previous findings, whether the focus in resected lobe or the neighboring.


Assuntos
Epilepsia , Humanos , Estudos Retrospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Tecnécio Tc 99m Exametazima
3.
Diagnostics (Basel) ; 13(8)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37189466

RESUMO

PURPOSE: Diffuse low-grade gliomas (DLGGs) are low-malignancy brain tumors originating from the glial cells of the brain growing continuously and infiltratively along the neural axons and infiltrating the surrounding brain tissue. DLGGs usually transform into higher malignancy, causing progressive disability and premature death. MRI scans are valuable when assessing soft tissue abnormalities, but, due to the infiltrative properties of DLGGs, delineating the tumor borders is a challenging task. Therefore, the aim of this study was to explore the difference in gross tumor volume (GTV) of DLGGs delineated from 7 Tesla and 3 Tesla MRI scans. METHOD: Patients were recruited at the department of neurosurgery and were scanned in both a 7T and a 3T MRI scanner prior to the operation. Two observers delineated the tumors using semi-automatic delineation software. The results from each observer were blinded to the other observer's delineation. RESULTS: Comparing GTVs from 7T and 3T, the percentage difference varied up to 40.4% on the T2-weighted images. The percentage difference in GTV varied up to 15.3% on the fluid-attenuated inversion recovery (FLAIR) images. On the T2-weighted images, most cases varied by approximately 15%; on the FLAIR sequence, half of the cases varied by approximately 5% and the other half by approximately 15%. The overall inter-observer agreement was near perfect, with an intraclass correlation of 0.969. The intraclass correlation was better on the FLAIR sequence than on the T2 sequence. CONCLUSION: Overall, the GTVs delineated from 7T images were smaller. The increase in field strength improved the inter-observer agreement only on the FLAIR sequence.

4.
Diagnostics (Basel) ; 13(10)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37238288

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance spectroscopy (MRS)-a method of analysing metabolites in vivo-has been utilized in several studies of brain glioma biomarkers at lower field strengths. At ultra-high field strengths, MRS provides an improved signal-to-noise-ratio and spectral resolution, but 7T studies on patients with gliomas are sparse. The purpose of this exploratory study was to evaluate the potential clinical implication of the use of single-voxel MRS at 7T to assess metabolic information on lesions in a pilot cohort of patients with grade II and III gliomas. METHODS: We scanned seven patients and seven healthy controls using the semi-localization by adiabatic-selective refocusing sequence on a Philips Achieva 7T system with a standard dual-transmit head coil. The metabolic ratios were calculated relative to water and total creatine. Additionally, 2-hydroxyglutarate (2-HG) MRS was carried out in four of the patients, and the 2-HG concentration was calculated relative to water. RESULTS: When comparing the tumour data to control regions in both patients and healthy controls, we found that the choline/creatine and myo-inositol/creatine ratios were significantly increased and that the N-acetylaspartate/creatine and the neurotransmitter glutamate/creatine ratios were significantly decreased. The N-acetylaspartate/water and glutamate/water ratios were also significantly decreased. The lactate/water and lactate/creatine ratios showed increases, although not significant. The GABA/water ratio was significantly decreased, but the GABA/creatine ratio was not. MRS spectra showed the presence of 2-HG in three of the four patients studied. Three of the patients, including the MRS 2-HG-negative patient, were operated on, and all of them had the IDH mutation. CONCLUSION: Our findings were consistent with the existing literature on 3T and 7T MRS.

5.
Acta Neurol Scand ; 142(6): 597-604, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32559313

RESUMO

BACKGROUND: Treatment options for the subgroup of people who develop long-lasting symptoms following mild traumatic brain injury are limited. Transcranial pulsating low-frequency electromagnetic stimulation (T-PEMF) in other patient groups has shown promising results in several studies with proposed neuroprotective and anti-inflammatory effects. OBJECTIVE: The present pilot study was conducted to access feasibility and tolerability of T-PEMF in treating post-concussion syndrome. METHODS: Seven patients with post-concussion syndrome received 5 weeks of daily 30 minutes T-PEMF treatment with evaluation after 2 and 5 weeks and 3 months after ending treatment. RESULTS: Compliance was high as all subject completed the full treatment. Two patients however experienced a worsening of their concussion symptoms during the course of treatment. The remaining patients had some discomfort in relation to treatment, mainly headache, but passing and less for each treatment. The majority (n = 5) had a reduction in symptoms overall, up to 61% (2%-61%) based on the Rivermead Post-Concussion Symptoms Questionnaire. CONCLUSION: Further studies on T-PEMF as a treatment option for post-concussion syndrome are warranted.


Assuntos
Síndrome Pós-Concussão/terapia , Estimulação Magnética Transcraniana/efeitos adversos , Estimulação Magnética Transcraniana/métodos , Adulto , Feminino , Humanos , Masculino , Projetos Piloto