Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Can J Cardiol ; 40(3): 457-467, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37923124

RESUMO

BACKGROUND: The risks of prefrail and frail women undergoing transcatheter aortic valve replacement (TAVR) have not been fully examined. The aim of the analysis was to assess the prognostic impact of prefrailty and frailty in women undergoing TAVR. METHODS: Women at intermediate or high surgical risk with severe aortic stenosis undergoing TAVR from the prospective multicentre WIN-TAVI (Women's International Transcatheter Aortic Valve Implantation) registry were stratified based on the number of Fried frailty criteria (weight loss, exhaustion, low physical activity, slow gait, weakness) met: nonfrail (no criteria), prefrail (1 or 2 criteria), or frail (3 or more criteria). The primary outcome at 1 year was the Valve Academic Research Consortium 2 (VARC-2) efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalisation for valve-related symptoms or heart failure, and valve-related dysfunction; secondary outcomes included the composite of VARC-2 life-threatening or major bleeding. RESULTS: Out of 1019 women, 297 (29.1%) met at least 1 frailty criterion: 264 (25.9%) had prefrailty and 33 (3.2%) frailty. The 1-year risk of the primary outcome was significantly higher in prefrail and frail (20.2%) than in nonfrail (14.9%) women (adjusted hazard ratio [aHR] 1.51, 95% confidence interval [CI] 1.07-2.12). The risk of VARC-2 life-threatening or major bleeding was higher in prefrail or frail (19.9%) than in nonfrail (10.0%) women (aHR 2.06, 95% CI 1.42-2.97). These risks were consistently increased in the prefrail and frail groups assessed separately. CONCLUSIONS: In women undergoing TAVR, the presence of prefrailty or frailty conferred an increased risk of the VARC-2 efficacy end point and of VARC-2 life-threatening or major bleeding.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fragilidade/complicações , Fragilidade/epidemiologia , Fragilidade/diagnóstico , Prognóstico , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Medição de Risco , Estudos Prospectivos , Resultado do Tratamento , Hemorragia/etiologia , Sistema de Registros , Valva Aórtica/cirurgia
2.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37968032

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Assuntos
Fibrilação Atrial , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Constrição Patológica/etiologia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica , Sistema de Registros , Desenho de Prótese
3.
Am J Cardiol ; 192: 221-227, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36848691

RESUMO

Early menopause is associated with an increased risk of cardiovascular diseases, including aortic stenosis (AS). We sought to investigate the prevalence and impact of early menopause on clinical outcomes in patients who underwent transcatheter aortic valve implantation (TAVI) for severe symptomatic AS. Women's International TAVI is a multinational, prospective, observational registry of women who underwent TAVI for severe symptomatic AS (n = 1,019). Patients were divided into 2 groups based on age of menopause: early menopause (age ≤45 years) and regular menopause (age >45 years). The primary outcome of interest was Valve Academic Research Consortium 2 efficacy end point, a composite of mortality, stroke, myocardial infarction, hospitalization for valve-related symptoms, or heart failure or valve-related dysfunction at 1-year follow-up. Of 732 patients with available data on menopause age, 173 (23.6%) were classified as having early menopause. These patients presented for TAVI at a younger age (81.6 ± 6.9 vs 82.7 ± 5.9, p = 0.05) and had a significantly lower Society of Thoracic Surgeons score (6.6 ± 4.8 vs 8.2 ± 7.1, p = 0.03) than those with regular menopause. However, the total valve calcium volume was smaller among patients with early versus regular menopause (731.8 ± 850.9 mm3 vs 807.6 ± 633.8 mm3, p = 0.002). Other co-morbidities were similar between the 2 groups. At 1-year follow-up, there were no significant differences in clinical outcomes between patients with early versus regular menopause (hazard ratio 1.00, 95% confidence interval 0.61 to 1.63, p = 1.00). In conclusion, despite presenting for TAVI at a younger age, patients with early menopause had a similar risk of adverse events as patients with regular menopause at 1 year after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Menopausa , Valva Aórtica/cirurgia
4.
Int J Cardiol ; 372: 40-45, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36455701

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become an accepted treatment for patients with severe aortic stenosis (AS). Predicting which patients are at risk for adverse clinical outcomes after TAVI remains difficult, especially in women. AIM: To identify predictors of adverse events in the WIN-TAVI cohort. METHODS: The WIN-TAVI study is an observational registry of 1019 women undergoing TAVI for severe symptomatic AS. Follow-up was 1 year. The primary outcome was defined according to VARC-2: a composite of mortality, stroke, myocardial infarction or hospitalization for valve-related symptoms or heart failure. The secondary outcome was a composite of cardiovascular mortality or hospitalization for valve-related symptoms or heart failure. RESULTS: We included 1019 women with severe AS (mean age of 82.5 ± 6.3 years). At 1 year, 16.4% of the patients experienced the primary endpoint and 12.6% the secondary endpoint. The use of oral anticoagulants (OAC) was the strongest independent predictor of the primary outcome (adjusted hazard ratio [aHR] 1.51, 95% confidence interval [CI] 1.079-2.106, p = 0.016). Independent predictors of the secondary endpoint were age (aHR 1.04 per year, 95% CI 1.01-1.074, p = 0.016) and use of OAC (aHR: 1.79, 95% CI 1.24-2.60, p = 0.002). OAC use was not associated with higher bleeding risk. CONCLUSION: Pre-procedural use of OAC was the strongest predictor of adverse outcomes during 1-year follow-up, likely reflecting a combination of high-risk factors and comorbidities, but was not related to increased bleeding risk.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Insuficiência Cardíaca/etiologia
5.
Am J Cardiol ; 172: 73-80, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35461697

RESUMO

Although most patients with small aortic annulus are women, there is paucity of data on the prognostic impact of small aortic prosthesis in women who underwent transcatheter aortic valve implantation (TAVI). Therefore, we aimed to evaluate the impact of small valve size on 1-year clinical outcomes after TAVI in women. The Women's INternational Transcatheter Aortic Valve Implantation is an all-women registry evaluating patients with severe aortic stenosis who underwent TAVI. Based on the size of the aortic bioprosthesis implanted, women were stratified into small (≤23 mm) and nonsmall (>23 mm) valve. The primary efficacy endpoint was the Valve Academic Research Consortium-2 composite of all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. Of 934 women who underwent TAVI, 388 (41.5%) received a small valve. Women with a small valve size had a lower body mass index, lower surgical risk scores, were less likely to suffer from atrial fibrillation, less often required postdilation and had a lower rate of residual aortic regurgitation grade ≥2. The occurrence of the Valve Academic Research Consortium-2 efficacy endpoint was similar between women treated with small and nonsmall valve (16.0% vs 16.3%, p = 0.881; adjusted hazard ratio 1.34, 95% confidence interval 0.90 to 2.00). Likewise, there were no significant differences in the occurrence of other secondary endpoints after multivariable adjustment. In conclusion, women with severe aortic stenosis who underwent TAVI with the implantation of a small valve bioprosthesis had similar 1-year outcomes as those receiving a nonsmall bioprosthesis.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Am Heart Assoc ; 11(6): e023454, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35114814

RESUMO

Background It is unknown whether contemporary drug-eluting stents have a similar safety profile in high bleeding risk patients treated with 1-month dual antiplatelet therapy following percutaneous coronary interventions. Methods and Results We performed an interventional, prospective, multicenter, single-arm trial, powered for noninferiority with respect to an objective performance criterion to evaluate the safety of percutaneous coronary interventions with Synergy bioresorbable-polymer everolimus-eluting stent followed by 1-month dual antiplatelet therapy in patients with high bleeding risk. In case of need for an oral anticoagulant, patients received an oral anticoagulant in addition to a P2Y12 inhibitor for 1 month, followed by an oral anticoagulant only. The primary end point was the composite of cardiac death, myocardial infarction, or definite or probable stent thrombosis at 1-year follow-up. The study was prematurely interrupted because of slow recruitment. From April 2017 to October 2019, 443 patients (age, 74.8±9.2 years; women, 29.1%) at 10 Italian centers were included. The 1-year primary outcome occurred in 4.82% (95% CI, 3.17%-7.31%) of patients, meeting the noninferiority compared with the predefined objective performance criterion of 9.4% and the noninferiority margin of 3.85% (Pnoninferiority<0.001) notwithstanding the lower-than-expected sample size. The rates of cardiac death, myocardial infarction, and definite or probable stent thrombosis were 1.88% (95% CI, 0.36%-2.50%), 3.42% (95% CI, 2.08%-5.62%), and 0.94% (95% CI, 0.35%-2.49%), respectively. Conclusions Among high bleeding risk patients undergoing percutaneous coronary interventions with the Synergy bioresorbable-polymer everolimus-eluting stent, a 1-month dual antiplatelet therapy regimen is safe, with low rates of ischemic and bleeding events. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03112707.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Implantes Absorvíveis , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes , Morte , Stents Farmacológicos/efeitos adversos , Everolimo/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros , Estudos Prospectivos , Trombose/etiologia , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(6): E908-E917, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34117817

RESUMO

OBJECTIVES: To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. BACKGROUND: Data on pacemaker insertion complicating TAVR in women are scarce. METHODS: The Women's International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. RESULTS: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85-7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30-0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9-16] days in PPI vs. 9 [7-14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adj HR 0.95, 95% CI 0.60-1.52, p = 0.84 and adj HR 1.22, 95% CI 0.83-1.79, p = 0.31, respectively). CONCLUSION: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Incidência , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32865860

RESUMO

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Complicações Pós-Operatórias , Prevalência , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Int J Cardiol ; 322: 65-69, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32814108

RESUMO

BACKGROUND: Female subjects constitute half of all transcatheter aortic valve implantation (TAVI) candidates, but the association between important comorbidities such as diabetes mellitus (DM) and clinical outcomes after TAVI remains unclear in this group. METHOD: WIN-TAVI is a real-world international registry of exclusively female subjects undergoing TAVI. The study population was stratified into those with (DM) and those without DM (NDM). Valve Academic Research Consortium (VARC)-2 efficacy (composite of all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or worsening congestive heart failure, or valve-related dysfunction) was the primary endpoint for this analysis. RESULTS: Of the 1012 subjects included in this study, 264 (26.1%) had DM at baseline. DM patients were younger but had a higher burden of comorbidities. There were no differences in VARC-2 efficacy events between DM and NDM patients at 30 days or 1 year. Conversely, patients with DM had a lower risk of VARC-2 life threatening bleeding at 30 days and 1 year after TAVI compared to NDM patients, which remained significant even after multivariable adjustment (HR, 0.34, 95% CI, 0.12-0.99; p = .047). In the subgroup analysis, insulin-dependent DM was not associated with an increased risk of adverse outcomes. CONCLUSIONS: Among female patients undergoing TAVI, more than one-fourth of the subjects presented with DM. At 1-year follow-up, DM was associated with lower bleeding complications and no increase in the risk of other adverse events, including mortality, after TAVI.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Sistema de Registros , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 97(5): E704-E715, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002302

RESUMO

OBJECTIVES: To assess the impact of anemia on clinical outcomes in female patients enrolled in the Women's InterNational transcatheter aortic valve implantation (WIN-TAVI) registry. BACKGROUND: Anemia is highly prevalent among females who constitute half of TAVI candidates, yet, its clinical significance remains poorly investigated. METHODS: Patients were divided into three groups according to preprocedural hemoglobin (Hb) level: (1) no anemia (Hb ≥12 g/dl), (2) mild-to-moderate anemia (10 ≤ Hb <12 g/dl), and (3) severe anemia (Hb <10 g/dl). The primary outcome was the occurrence of Valve Academic Research Consortium (VARC)-2 efficacy endpoint, a composite of mortality, stroke, myocardial infarction (MI), hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. RESULTS: Hemoglobin level was available in 877 (86.1%) patients: 412 (47.0%) had no anemia, 363 (41.4%) had mild-to-moderate anemia, and 102 (11.6%) had severe anemia. The latter group had a higher prevalence of cardiovascular risk factors. Compared with patients without anemia, severe anemia was associated with a greater risk of VARC-2 efficacy endpoint (adj HR 1.71, 95% CI: 1.02-2.87, p = .04), all-cause death (adj HR 2.36, 95% CI: 1.31-4.26, p = .004) and a composite of death, MI or stroke (adj HR 1.88, 95% CI: 1.10-3.22, p = .02) at 1 year. Moreover, an increased risk of late mortality (adj HR 1.15, 95% CI: 1.02-1.30, p = .03) was observed with every 1 g/dl decrease in hemoglobin level. CONCLUSION: Severe anemia in females undergoing TAVI was independently associated with increased rates of VARC-2 efficacy endpoint and mortality at 1 year.


Assuntos
Anemia , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Anemia/epidemiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Circ Cardiovasc Interv ; 13(7): e008714, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32646304

RESUMO

BACKGROUND: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis. METHODS: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve. RESULTS: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P=0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P=0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P=0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P=0.043). CONCLUSIONS: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Europa (Continente) , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 96(1): 198-207, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31977142

RESUMO

BACKGROUND: The prevalence of both chronic kidney disease (CKD) and aortic stenosis (AS) increase with age. Although baseline CKD is frequent in patients undergoing transcatheter aortic valve replacement (TAVR), its significance among women is largely unknown. METHODS: Women's INternational Transcatheter Aortic Valve Implantation (WIN-TAVI) is a multinational, prospective registry of women undergoing TAVR for severe AS. We included patients with available baseline estimated glomerular filtration rate (eGFR) and completed 1-year follow-up. Patients were categorized into three groups based on their eGFR: No CKD (normal kidney function to stage 2 CKD: eGFR ≥60 ml/min/1.73 m2 ); (b) mild CKD (stage 3a CKD: eGFR = 45-59 ml/min/1.73 m2 ); and (c) moderate/severe CKD (stage ≥3b CKD: eGFR <45 ml/min/1.73 m2 ). All events were adjudicated according to the Valve Academic Research Consortium (VARC)-2 criteria. RESULT: Out of 852 women undergoing TAVR, 326 (38.3%) had no CKD, 225 (26.4%) had mild CKD, and 301 (35.3%) had moderate/severe CKD. Women with higher stage of CKD at baseline were more likely to have a history of hypertension, diabetes, atrial fibrillation, anemia, chronic lung disease, hemodialysis, prior percutaneous coronary intervention, and pacemaker implantation. After multivariate adjustment, moderate/severe CKD was associated with a greater risk of 1-year VARC-2 safety endpoints [hazard ratio (HR) 1.68, 95% confidence interval (CI): 1.10-2.60], all-cause death (HR 2.00, 95% CI: 1.03-3.90), and composite of death, myocardial infarction, stroke or life-threatening bleeding (HR 1.70, 95% CI: 1.04-2.76). There were no differences in 30-day and 1-year VARC-2 efficacy and 30-day VARC-2 safety outcomes. CONCLUSION: CKD is associated with substantial and independent risk for mortality and morbidity at 1-year follow-up in women undergoing TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Taxa de Filtração Glomerular , Humanos , Rim/fisiopatologia , Sistema de Registros , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
Heart ; 106(7): 487-492, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31932287

RESUMO

There are important dissimilarities in clinical presentation, aggregation of comorbidities, cardiovascular risk factors and the quality of delivery of medical care among men and women with acute coronary syndrome (ACS). Compared with men, despite the well-known older age and more pronounced frailty, women with ACS present later from symptom onset and are at high bleeding risk after invasive procedures. In addition, autoimmune/inflammatory disease, fibromuscular dysplasia, polycystic ovary, early menopause and history of pre-eclampsia are risk factors preceding ACS among younger women. They more often experience myocardial infarction in the absence of obstructive coronary arteries (MINOCA), which makes diagnosis and treatment of ACS among women more challenging compared with men. Women and men do both benefit from guideline-recommended treatment, although, compared with men, women with ACS have a higher adjusted risk of early death, which equalises between both sexes within the first year. Young women with ACS suffer frequently of depression and present often with MINOCA. Compared with young men, they (young women) have a higher risk of death. Therefore, focusing on young patients with ACS, understanding the particular physiopathology of MINOCA and developing programmes targeting comorbidities and depression-related behavioural risk factors are urgently needed.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Saúde da Mulher
17.
Am J Cardiol ; 125(3): 441-448, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31813530

RESUMO

We sought to analyze outcomes of women receiving balloon-expandable valves (BEV) or self-expanding valves (SEV) in contemporary transcatheter aortic valve implantation (TAVI). WIN TAVI (Women's INternational Transcatheter Aortic Valve Implantation) is the first all-female TAVI registry to study the safety and performance of TAVI in women. We compared women treated with BEV (n = 408, 46.9%) versus those treated with SEV (n = 461, 53.1%). The primary efficacy end point was the Valve Academic Research Consortium-2 (VARC-2) composite of 1-year all-cause death, stroke, myocardial infarction, hospitalization for valve-related symptoms or heart failure or valve-related dysfunction. Women receiving SEV had higher surgical risk scores, higher rate of previous stroke and pulmonary hypertension whereas women receiving BEV were more frequently denied surgical valve replacement due to frailty. BEV patients were less likely to require post-dilation and had significantly lower rates of residual aortic regurgitation grade ≥2 (9.8% vs 4.7%, p = 0.007). At 1 year, the crude incidence and adjusted risk of the primary VARC-2 efficacy end point was similar between groups (17.1% with SEV and 14.3% with BEV, p = 0.25; hazards ratio 1.09, 95% confidence interval 0.68 to 1.75). Conversely the crude rate and adjusted risk of new pacemaker implantation was higher with SEV than BEV (15% vs 8.6%, p = 0.001; hazards ratio 1.97, 95% confidence interval 1.13 to 3.43). A subanalysis on new generation valves showed no difference in the need for pacemaker implantation between the 2 devices (10.1% vs 8.0%, p = 0.56). In conclusion, in contemporary TAVI, SEV are used more frequently in women with greater co-morbidities. While there were no differences in unadjusted and adjusted risk of 1-year primary efficacy end point between the valve types, there was a greater need for permanent pacemakers after SEV implantation.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Causas de Morte/tendências , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico , Desenho de Prótese , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
19.
JACC Cardiovasc Interv ; 12(16): 1566-1576, 2019 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-31202946

RESUMO

OBJECTIVES: The purpose of the study was to investigate the impact of oral anticoagulation (OAC) type on clinical outcomes 1 year after transcatheter aortic valve replacement (TAVR). BACKGROUND: Non-vitamin K oral anticoagulants (NOACs) are superior to vitamin K antagonists (VKAs) in nonvalvular atrial fibrillation (AF), while their comparative performance among patients in need of OAC undergoing TAVR is underinvestigated. METHODS: The study enrolled 962 consecutive patients who underwent TAVR in 4 tertiary European centers and were discharged on either NOACs (n = 326) or VKAs (n = 636). By using propensity scores for inverse probability of treatment weighting (IPTW), the comparison of treatment groups was adjusted to correct for potential confounding. RESULTS: Mean age and Society of Thoracic Surgeons score of the population were 81.3 ± 6.3 years and 4.5% (interquartile range: 3.0% to 7.3%); 52.5% were women and a balloon-expandable valve was used in 62.7% of cases. The primary outcome of interest, combined incidence of all-cause mortality, myocardial infarction, and any cerebrovascular event at 1-year after TAVR, was 21.2% with NOACs versus 15.0% with VKAs (hazard ratio [HR]: 1.44; 95% confidence interval [CI]: 1.00 to 2.07; p = 0.050, IPTW-adjusted). The 1-year incidence of any Bleeding Academic Research Consortium bleeds and all-cause mortality were comparable between the NOAC and VKA groups, 33.9% versus 34.1% (HR: 0.97; 95% CI: 0.74 to 1.26; p = 0.838, IPTW-adjusted) and 16.5% versus 12.2% (HR: 1.36; 95% CI: 0.90 to 2.06; p = 0.136, IPTW-adjusted), respectively. CONCLUSIONS: Chronic use of both NOACs and VKAs among patients in need of OAC after TAVR are comparable regarding 1-year bleeding risk. The higher ischemic event rate observed with NOACs needs to be evaluated in large randomized trials.


Assuntos
Anticoagulantes/administração & dosagem , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrinolíticos/administração & dosagem , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Europa (Continente) , Inibidores do Fator Xa/administração & dosagem , Feminino , Fibrinolíticos/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/mortalidade , Humanos , Masculino , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Vitamina K/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...