Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
J Pers Med ; 14(6)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38929858

RESUMO

PURPOSE: Imaging of the delicate inner ear morphology has become more and more precise owing to the rapid progress in magnetic resonance imaging (MRI). However, in clinical practice, the interpretation of imaging findings is hampered by a limited knowledge of anatomical details which are frequently obscured by artifacts. Corresponding review articles are as rare in journals as they are in reference books. This shortness prompted us to perform a direct comparison of imaging with anatomical whole-mount sections as a reference. It was the intention of this paper to compare the microscopic anatomy of a human inner ear as shown on anatomical whole-mount sections with high-resolution MRI and cone beam computed tomography (CBCT). Both are available in clinical routine and depict the structures with maximum spatial resolution. It was also a goal of this work to clarify if structures that were observed on MRI in a regular manner correlate with factual inner ear anatomy or correspond with artifacts typical for imaging. METHODS: A fresh human anatomical specimen was examined on a clinical 3-Tesla MRI scanner using a dedicated surface coil. The same specimen was then studied with CBCT. In each imaging modality, high-resolution 3D data sets which enabled multiplanar reformatting were created. In the second step, anatomical whole-mount sections of the specimen were cut and stained. This process enabled a direct comparison of imaging with anatomical conditions. RESULTS: Clinical MRI was able to depict the inner ear with remarkable anatomical precision. Strongly T2-weighted imaging protocols are exquisitely capable of showing the fluid-filled components of the inner ear. The macular organs, ampullar crests and cochlear aqueduct were clearly visible. Truncation artifacts are prone to be confused with the delicate membrane separating the endolymphatic from the perilymphatic compartment. However, it was not possible to directly depict this borderline. CONCLUSIONS: With the maximum resolution of magnetic resonance tomography, commonly used in everyday clinical practice, even the smallest details of the inner ear structures can be reliably displayed. However, it is important to distinguish between truncation artifacts and true anatomical structures. Therefore, this study can be useful as a reference for image analysis.

2.
Surg Radiol Anat ; 46(8): 1231-1235, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38926224

RESUMO

PURPOSE: The topic of osseous variations of the craniocervical junction is a complex morphological and embryological chapter of human anatomy, with a possible impact on neurogical and vascular functionality in this morphological variable region. MATERIAL & METHODS: An until now undescribed anatomical variation of the exoccipital part of the occipital bone has been observed after maceration at the outer skull base of a West-European 68-year-old male body donor. RESULTS: On both sites of the foramen magnum accessory osseous processes were observed that arise from the jugular process and point towards the lateral margin of the foramen magnum. On the left site this process forms a full arc that bridges the condylar fossa completely. CONCLUSION: The observed osseous bridge over the condylar fossa has not been reported on before and can be explained by the partial persistence of a primordial vertebra between atlas and occipital bone: the Proatlas. The resulting accessory structure may affect due to its topographic conditions the V3-Segment of the vertebral artery and its accompanying nerves, and thus, play a role in diagnosis and therapy of vascular and/or neurological symptoms of head and neck.


Assuntos
Variação Anatômica , Forame Magno , Osso Occipital , Base do Crânio , Humanos , Masculino , Idoso , Osso Occipital/anormalidades , Osso Occipital/anatomia & histologia , Base do Crânio/anatomia & histologia , Base do Crânio/diagnóstico por imagem , Forame Magno/anatomia & histologia , Forame Magno/anormalidades , Cadáver
3.
Eur Radiol Exp ; 8(1): 66, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38834751

RESUMO

BACKGROUND: Quantitative techniques such as T2 and T1ρ mapping allow evaluating the cartilage and meniscus. We evaluated multi-interleaved X-prepared turbo-spin echo with intuitive relaxometry (MIXTURE) sequences with turbo spin-echo (TSE) contrast and additional parameter maps versus reference TSE sequences in an in situ model of human cartilage defects. METHODS: Standardized cartilage defects of 8, 5, and 3 mm in diameter were created in the lateral femora of ten human cadaveric knee specimens (81 ± 10 years old; nine males, one female). MIXTURE sequences providing proton density-weighted fat-saturated images and T2 maps or T1-weighted images and T1ρ maps as well as the corresponding two- and three-dimensional TSE reference sequences were acquired before and after defect creation (3-T scanner; knee coil). Defect delineability, bone texture, and cartilage relaxation times were quantified. Appropriate parametric or non-parametric tests were used. RESULTS: Overall, defect delineability and texture features were not significantly different between the MIXTURE and reference sequences (p ≤ 0.47). After defect creation, relaxation times significantly increased in the central femur (T2pre = 51 ± 4 ms [mean ± standard deviation] versus T2post = 56 ± 4 ms; p = 0.002) and all regions combined (T1ρpre = 40 ± 4 ms versus T1ρpost = 43 ± 4 ms; p = 0.004). CONCLUSIONS: MIXTURE permitted time-efficient simultaneous morphologic and quantitative joint assessment based on clinical image contrasts. While providing T2 or T1ρ maps in clinically feasible scan time, morphologic image features, i.e., cartilage defects and bone texture, were comparable between MIXTURE and reference sequences. RELEVANCE STATEMENT: Equally time-efficient and versatile, the MIXTURE sequence platform combines morphologic imaging using familiar contrasts, excellent image correspondence versus corresponding reference sequences and quantitative mapping information, thereby increasing the diagnostic value beyond mere morphology. KEY POINTS: • Combined morphologic and quantitative MIXTURE sequences are based on three-dimensional TSE contrasts. • MIXTURE sequences were studied in an in situ human cartilage defect model. • Morphologic image features, i.e., defect delineabilty and bone texture, were investigated. • Morphologic image features were similar between MIXTURE and reference sequences. • MIXTURE allowed time-efficient simultaneous morphologic and quantitative knee joint assessment.


Assuntos
Cadáver , Cartilagem Articular , Articulação do Joelho , Imageamento por Ressonância Magnética , Humanos , Masculino , Imageamento por Ressonância Magnética/métodos , Feminino , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Idoso de 80 Anos ou mais , Idoso
4.
Ann Anat ; 255: 152294, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38889825

RESUMO

BACKGROUND: Orbital floor fractures result in critical changes in the shape and inferior rectus muscle (IRM) position. Radiological imaging of IRM changes can be used for surgical decision making or prediction of ocular symptoms. Studies with a systematic consideration of the orbital floor defect ratio in this context are missing in the literature. Accordingly, this study on human cadavers aimed to systematically investigate the impact of the orbital floor defect ratio on changes in the IRM and the prediction of posttraumatic enophthalmos. METHODS: Seventy-two orbital floor defects were placed in cadaver specimens using piezosurgical removal. The orbital defect area (ODA), orbital floor area (OFA), position and IRM shape, and enophthalmos were measured using computed tomography (CT) scans. RESULTS: The ODA/OFA ratio correlated significantly (p < 0.001) with the shape (Spearman's rho: 0.558) and position (Spearman's rho: 0.511) of the IRM, and with enophthalmos (Spearman's rho: 0.673). Increases in the ODA/OFA ratio significantly rounded the shape of the IRM (ß: 0.667; p < 0.001) and made a lower position of the IRM more likely (OR: 1.093; p = 0.003). In addition, increases in the ODA/OFA ratio were significantly associated with the development of relevant enophthalmos (OR: 1.159; p = 0.008), adjusted for the defect localization and shape of the IRM. According to receiver operating characteristics analysis (AUC: 0.876; p < 0.001), a threshold of ODA/OFA ratio ≥ 32.691 for prediction of the risk of development of enophthalmos yielded a sensitivity of 0.809 and a specificity of 0.842. CONCLUSION: The ODA/OFA ratio is a relevant parameter in the radiological evaluation of orbital floor fractures, as it increases the risk of relevant enophthalmos, regardless of fracture localization and shape of the IRM. Therefore, changes in the shape and position of the IRM should be considered in surgical treatment planning. A better understanding of the correlates of isolated orbital floor fractures may help to develop diagnostic scores and standardize therapeutic algorithms in the future.


Assuntos
Cadáver , Enoftalmia , Músculos Oculomotores , Órbita , Fraturas Orbitárias , Tomografia Computadorizada por Raios X , Humanos , Enoftalmia/etiologia , Enoftalmia/diagnóstico por imagem , Músculos Oculomotores/diagnóstico por imagem , Masculino , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/complicações , Fraturas Orbitárias/cirurgia , Fraturas Orbitárias/patologia , Feminino , Idoso , Órbita/diagnóstico por imagem , Órbita/lesões , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
5.
Diagnostics (Basel) ; 14(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38786276

RESUMO

Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: "MIX1", combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and "MIX2", combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.

6.
Clin Biomech (Bristol, Avon) ; 114: 106239, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38599132

RESUMO

BACKGROUND: The application of expandable titanium-cages has gained widespread use in vertebral body replacement for indications such as burst fractures, tumors and infectious destruction. However, torque forces necessary for a satisfactory expansion of these implants and for subsidence of them into the adjacent vertebrae are unknown within the osteoporotic spine. METHODS: Six fresh-frozen human, osteoporotic, lumbar spines were dorsally instrumented with titanium implants (L2-L4) and a partial corpectomy of L3 was performed. An expandable titanium-cage was inserted ventrally and expanded by both residents and senior surgeons until fixation was deemed sufficient, based on haptic feedback. Torque forces for expansion were measured in Nm. Expansion was then continued until cage subsidence occurred. Torque forces necessary for subsidence were recorded. Strain of the dorsal rods during expansion was measured with strain gauges. FINDINGS: The mean torque force for fixation of cages was 1.17 Nm (0.9 Nm for residents, 1.4 Nm for senior surgeons, p = .06). The mean torque force for subsidence of cages was 3.1 Nm (p = .005). Mean peak strain of the dorsal rods was 970 µm/m during expansion and 1792 µm/m at subsidence of cages (p = .004). INTERPRETATION: The use of expandable titanium-cages for vertebral body replacement seems to be a primarily safe procedure even within the osteoporotic spine as torque forces required for subsidence of cages are nearly three times higher than those needed for fixation. Most of the expansion load is absorbed by straining of the dorsal instrumentation. Rod materials other than titanium may alter the torque forces found in this study.


Assuntos
Fusão Vertebral , Titânio , Humanos , Corpo Vertebral , Torque , Vértebras Lombares/cirurgia , Próteses e Implantes
7.
J Pers Med ; 14(2)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38392583

RESUMO

BACKGROUND: The recurrence or persistence of symptoms after thoracic outlet decompression (TOD) in patients with neurogenic thoracic outlet syndrome (NTOS) is not uncommon. Some authors have shown significantly better clinical outcomes in patients who underwent TOD with exarticulation of the first rib compared to a group who underwent TOD with preservation of the dorsal portion of the first rib. Several other case series have shown significant improvement after redo surgery with removal of the dorsal first rib remnant. This indicates the importance of the dorsal part of the first rib in NTOS. However, radical exarticulation may not always be necessary. In this study, we tried to answer the question of whether there is a morphological difference in the dorsal part of the first rib in NTOS patients that might help in the diagnosis and treatment of NTOS. METHODS: We used the CT data of 21 NTOS patients who underwent TOD surgery and measured the dorsal part of the first rib, then compared them with a quota sample. RESULTS: We found no difference in the dorsal part of the first rib between NTOS patients and the quota sample in our data. CONCLUSIONS: As there was no detectable difference, we were not able to use these data to help decide whether exarticulation is necessary in achieving adequate symptom relief. Therefore, we advocate exarticulation of the first rib when TOD is indicated.

8.
Clin Oral Investig ; 28(3): 182, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38424318

RESUMO

OBJECTIVES: The present study aims to assess the impact of bilateral and high oblique sagittal split osteotomy (BSSO/HSSO), as well as displacement distances and directions on the expected and achievable bone contact area (BCA) and changes in the intercondylar distance (ICD). The primary question addressed is whether mandibular splitting through BSSO results in a greater BCA and/or ICD when compared to splitting through HSSO. MATERIALS AND METHODS: Totally 80 mandibular displacements were performed on 20 fresh cadavers, for each subject, four splints were produces to facilitate mandibular advancement as well as setbacks of 4 and 8 mm. Pre- and postoperative CBCT scans were performed to plan the surgical procedures and to analyze the expected and achieved BCA and ICD. RESULTS: Regarding the maximum mandibular displacement, the expected BCA for HSSO/BSSO were 352.58 ± 96.55mm2 and 1164.00 ± 295.50mm2, respectively, after advancement and 349.11 ± 98.42mm2 and 1344.70 ± 287.23mm2, respectively, after setback. The achieved BCA for HSSO/BSSO were 229.37 ± 75.90mm2 and 391.38 ± 189.01mm2, respectively, after advancement and 278.03 ± 97.65mm2 and 413.52 ± 169.52 mm2, respectively after setback. The expected ICD for HSSO/BSSO were 4.51 ± 0.73 mm and 3.25 ± 1.17 mm after advancement and - 5.76 ± 1.07 mm and - 4.28 ± 1.58 mm after setback. The achieved ICD for HSSO/BSSO were 2.07 ± 2.9 mm and 1.7 ± 0.60 mm after advancement and - 2.57 ± 2.78 mm and - 1.28 ± 0.84 mm after setback. Significant differences between the BCA after HSSO and BSSO were at each displacement (p < 0.001), except for the achieved BCA after 8-mm setback and advancement (p ≥ 0.266). No significant differences were observed regarding ICD, except for the expected ICD after 8-mm setback and advancement (p ≤ 0.037). CONCLUSIONS: Compared to the virtual planning, the predictability regarding BCA and ICD was limited. ICD showed smaller clinical changes, BCA decreased significantly in the BSSO group. CLINICAL RELEVANCE: BCA and ICD might have been less important in choosing the suitable split technique. in orthognathic surgery.


Assuntos
Má Oclusão , Avanço Mandibular , Cirurgia Ortognática , Sitosteroides , Humanos , Osteotomia Sagital do Ramo Mandibular/métodos , Mandíbula/cirurgia
9.
J Biomed Mater Res B Appl Biomater ; 112(1): e35339, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37955803

RESUMO

Pedicle screw instrumentation has become "state of the art" in surgical treatment of many spinal disorders. Loosening of pedicle screws due to poor bone mineral density is a frequent complication in osteoporotic patients. As prevalence of osteoporosis and spinal disorders are increasing with an aging demographic, optimizing the biomechanical properties of pedicle screw constructions and therefore outcome after spinal surgery in osteoporotic patients is a key factor in future surgical therapy. Therefore, this biomechanical study investigated the stability of polymethylmethacrylate (PMMA)-augmented pedicle screw-rod constructions under a deviating distribution of PMMA applied to the instrumentation in osteoporotic human cadaveric vertebrae. We showed that PMMA-augmented pedicle screw-rod constructions tend to be more stable than those with non-augmented pedicle screws. Further, there appears to be a larger risk of screw loosening in unilateral augmented pedicle screws than in non-augmented, therefore a highly asymmetrically distributed PMMA should be avoided.


Assuntos
Parafusos Pediculares , Humanos , Polimetil Metacrilato , Vértebras Lombares/cirurgia , Fenômenos Biomecânicos , Cimentos Ósseos
10.
Arch Orthop Trauma Surg ; 144(3): 1047-1053, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38114739

RESUMO

INTRODUCTION: Avoiding overlengthening in radial head arthroplasty (RHA) is essential for the prognosis of the elbow joint. An overlengthening from 2 mm is visible due to widening of the anterolateral ulnohumeral joint space but intraoperatively, this particular joint space is difficult to visualize. The commonly used Kocher approach allows visualization of the posterolateral joint space without additional instruments or further surgical release of the already unstable elbow. The aim of our study was to investigate whether the visualization of the posterolateral joint space is also a reliable method to indicate overlengthening in RHA. MATERIAL AND METHODS: RHA was performed in five human cadaveric specimens with the forearm, wrist, and hand intact. The lateral ligament complex was detached and an anatomic transosseous refixation was performed. Six stages of implantation heights were documented: native joint (1), RHA at the anatomic height (2), + 2 mm (3), + 4 mm (4), + 6 mm (5) and - 2 mm (6). Macroscopic measurement and digital image analysis of the posterolateral and anterolateral ulnohumeral joint spaces were performed. RESULTS: All stages of overlengthening showed a significant increase in posterolateral and anterolateral joint space widening (p < 0.05). The posterior and anterior joint space showed excellent intraclass correlation. CONCLUSION: Visualization of the posterolateral aspect of the ulnohumeral joint space is a reliable indicator for overlengthening in RHA without further compromising an already unstable elbow. Correlation to the findings of the anterolateral ulnohumeral joint space in different implants leads to the assumption that visualization of either the anterior or posterior ulnohumeral joint space is universally applicable to determine overlengthening in RHA, regardless of the type of the radial head implant.


Assuntos
Articulação do Cotovelo , Fraturas do Rádio , Humanos , Rádio (Anatomia)/cirurgia , Articulação do Cotovelo/cirurgia , Artroplastia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Cotovelo/cirurgia
11.
Clin Biomech (Bristol, Avon) ; 109: 106075, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37651900

RESUMO

BACKGROUND: Vertebral body replacement is a common surgical procedure for treatment of disorders associated with spinal instability. Therefore, pedicle screws are usually inserted in adjacent vertebrae for stabilization of the posterior column, however, there is lack of evidence whether implantation of index-level pedicle screws is beneficial or not. This biomechanical study aims to investigate the effect of pedicle screw instrumentation on axial stability following vertebral body replacement. METHODS: Unstable fracture at L3 level was simulated in lumbar spines from six human cadaveric specimens. Then instrumentation was performed one level above / one level below index level in three specimens and further, three specimens were instrumented at index-level (L3) additionaly. Then we used a testing protocol for biomechanical evaluation of axial loading on human cadaveric lumbar spines until cage subsidence occurred. FINDINGS: Our results show that index-level instrumented spines endured significantly higher load until cage subsidence occurred compared to non-index-level instrumented specimens (p = 0.05). INTERPRETATION: Our results demonstrate pedicle screw instrumentation at index-level vertebra should be considered when possbile as it may have a protective effect against cage subsidence in patients undergoing vertebral body replacement surgery.

12.
Anat Sci Educ ; 16(5): 814-829, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37183973

RESUMO

Hands-on courses utilizing preserved human tissues for educational training offer an important pathway to acquire basic anatomical knowledge. Owing to the reevaluation of formaldehyde limits by the European Commission, a joint approach was chosen by the German-speaking anatomies in Europe (Germany, Austria, Switzerland) to find commonalities among embalming protocols and infrastructure. A survey comprising 537 items was circulated to all anatomies in German-speaking Europe. Clusters were established for "ethanol"-, formaldehyde-based ("FA"), and "other" embalming procedures, depending on the chemicals considered the most relevant for each protocol. The logistical framework, volumes of chemicals, and infrastructure were found to be highly diverse between the groups and protocols. Formaldehyde quantities deployed per annum were three-fold higher in the "FA" (223 L/a) compared to the "ethanol" (71.0 L/a) group, but not for "other" (97.8 L/a), though the volumes injected per body were similar. "FA" was strongly related to table-borne air ventilation and total fixative volumes ≤1000 L. "Ethanol" was strongly related to total fixative volumes >1000 L, ceiling- and floor-borne air ventilation, and explosion-proof facilities. Air ventilation was found to be installed symmetrically in the mortuary and dissection facilities. Certain predictors exist for the interplay between the embalming used in a given infrastructure and technical measures. The here-established cluster analysis may serve as decision supportive tool when considering altering embalming protocols or establishing joint protocols between institutions, following a best practice approach to cater toward best-suited tissue characteristics for educational purposes, while simultaneously addressing future demands on exposure limits.


Assuntos
Anatomia , Humanos , Fixadores , Anatomia/educação , Embalsamamento/métodos , Cadáver , Formaldeído/química , Etanol
13.
Heliyon ; 9(4): e14117, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37057051

RESUMO

Introduction: During the SARS-CoV-2-pandemic, face masks have become one of the most important ubiquitous factors affecting human breathing. It increases the resistance and dead space volume leading to a re-breathing of CO2. So far, this phenomenon and possible implications on early life has not been evaluated in depth. Method: As part of a scoping review, literature was systematically reviewed regarding CO2 exposure and facemask use. Results: Fresh air has around 0.04% CO2, while wearing masks more than 5 min bears a possible chronic exposure to carbon dioxide of 1.41% to 3.2% of the inhaled air. Although the buildup is usually within the short-term exposure limits, long-term exceedances and consequences must be considered due to experimental data. US Navy toxicity experts set the exposure limits for submarines carrying a female crew to 0.8% CO2 based on animal studies which indicated an increased risk for stillbirths. Additionally, mammals who were chronically exposed to 0.3% CO2 the experimental data demonstrate a teratogenicity with irreversible neuron damage in the offspring, reduced spatial learning caused by brainstem neuron apoptosis and reduced circulating levels of the insulin-like growth factor-1. With significant impact on three readout parameters (morphological, functional, marker) this chronic 0.3% CO2 exposure has to be defined as being toxic. Additional data exists on the exposure of chronic 0.3% CO2 in adolescent mammals causing neuron destruction, which includes less activity, increased anxiety and impaired learning and memory. There is also data indicating testicular toxicity in adolescents at CO2 inhalation concentrations above 0.5%. Discussion: There is a possible negative impact risk by imposing extended mask mandates especially for vulnerable subgroups. Circumstantial evidence exists that extended mask use may be related to current observations of stillbirths and to reduced verbal motor and overall cognitive performance in children born during the pandemic. A need exists to reconsider mask mandates.

14.
Front Public Health ; 11: 1125150, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37089476

RESUMO

Background: As face masks became mandatory in most countries during the COVID-19 pandemic, adverse effects require substantiated investigation. Methods: A systematic review of 2,168 studies on adverse medical mask effects yielded 54 publications for synthesis and 37 studies for meta-analysis (on n = 8,641, m = 2,482, f = 6,159, age = 34.8 ± 12.5). The median trial duration was only 18 min (IQR = 50) for our comprehensive evaluation of mask induced physio-metabolic and clinical outcomes. Results: We found significant effects in both medical surgical and N95 masks, with a greater impact of the second. These effects included decreased SpO2 (overall Standard Mean Difference, SMD = -0.24, 95% CI = -0.38 to -0.11, p < 0.001) and minute ventilation (SMD = -0.72, 95% CI = -0.99 to -0.46, p < 0.001), simultaneous increased in blood-CO2 (SMD = +0.64, 95% CI = 0.31-0.96, p < 0.001), heart rate (N95: SMD = +0.22, 95% CI = 0.03-0.41, p = 0.02), systolic blood pressure (surgical: SMD = +0.21, 95% CI = 0.03-0.39, p = 0.02), skin temperature (overall SMD = +0.80 95% CI = 0.23-1.38, p = 0.006) and humidity (SMD +2.24, 95% CI = 1.32-3.17, p < 0.001). Effects on exertion (overall SMD = +0.9, surgical = +0.63, N95 = +1.19), discomfort (SMD = +1.16), dyspnoea (SMD = +1.46), heat (SMD = +0.70), and humidity (SMD = +0.9) were significant in n = 373 with a robust relationship to mask wearing (p < 0.006 to p < 0.001). Pooled symptom prevalence (n = 8,128) was significant for: headache (62%, p < 0.001), acne (38%, p < 0.001), skin irritation (36%, p < 0.001), dyspnoea (33%, p < 0.001), heat (26%, p < 0.001), itching (26%, p < 0.001), voice disorder (23%, p < 0.03), and dizziness (5%, p = 0.01). Discussion: Masks interfered with O2-uptake and CO2-release and compromised respiratory compensation. Though evaluated wearing durations are shorter than daily/prolonged use, outcomes independently validate mask-induced exhaustion-syndrome (MIES) and down-stream physio-metabolic disfunctions. MIES can have long-term clinical consequences, especially for vulnerable groups. So far, several mask related symptoms may have been misinterpreted as long COVID-19 symptoms. In any case, the possible MIES contrasts with the WHO definition of health. Conclusion: Face mask side-effects must be assessed (risk-benefit) against the available evidence of their effectiveness against viral transmissions. In the absence of strong empirical evidence of effectiveness, mask wearing should not be mandated let alone enforced by law. Systematic review registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021256694, identifier: PROSPERO 2021 CRD42021256694.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , COVID-19/epidemiologia , Máscaras , SARS-CoV-2 , Pandemias , Dióxido de Carbono , Síndrome de COVID-19 Pós-Aguda , Dispneia
15.
J Anat ; 243(1): 138-147, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36863846

RESUMO

The craniocervical junction (CCJ) of humans and other vertebrates is a developmental restless region. Due to complex phylogenetic and ontogenetic processes, many anatomical variations can be found in that transitional area. Therefore, newly described variants must be registered, named, and classified into existing concepts explaining their genesis. This study aimed to describe and classify anatomical peculiarities that have not or rarely been reported on before in the literature. This study is based on the observation, analysis, classification, and documentation of three rare phenomena of three different human skull bases and upper cervical vertebrae, which come from the body donor program of the RWTH Aachen. As a result, three osseous phenomena (accessory ossicles, spurs, and bridges) at the CCJ of three different body donors could have been documented, measured, and interpreted. Due to extensive collecting efforts, careful maceration, and accurate observation, it is still possible to add new phenomena to the long list of Proatlas-manifestations. Further on, it could have been shown again that these manifestations can cause damage to the elements of the CCJ due to altered biomechanic conditions. Finally, we have succeeded in showing that phenomena can exist that can imitate the presence of a Proatlas-manifestation. Here, a precise differentiation between Proatlas-based supernumerary structures and the results of fibroostotic processes is necessary.


Assuntos
Vértebras Cervicais , Osso Occipital , Humanos , Filogenia , Base do Crânio
16.
Clin Biomech (Bristol, Avon) ; 103: 105925, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36863219

RESUMO

INTRODUCTION: Despite good screw anchorage and safe screw trajectory, screw loosening occurs in several cases, especially in osteoporotic individuals. The aim of this biomechanical analysis was to evaluate the primary stability of revision screw placement in individuals with reduced bone quality. Therefore, revision via enlarged diameter screws was compared to the use of human bone matrix as augmentation to improve the bone stock and screw coverage. METHODS: 11 lumbar vertebral bodies from cadaveric specimens with a mean age of 85.7 years (± 12.0 years) at death were used. 6.5 mm diameter pedicle screws were inserted in both pedicles and hereafter loosened using a fatigue protocol. Screws were revised inserting a larger diameter screw (8.5 mm) in one pedicle and a same diameter screw with human bone matrix augmentation in the other pedicle. The previous loosening protocol was then reapplied, comparing maximum load and cycles to failure between both revision techniques. Insertional torque was continuously measured during insertion of both revision screws. FINDINGS: The number of cycles and the maximum load until failure were significantly greater in enlarged diameter screws than in augmented screws. The enlarged screws' insertional torque was also significantly higher than of the augmented screws. INTERPRETATION: Human bone matrix augmentation does not reach the same ad-hoc fixation strength as enlarging the screw's diameter by 2 mm and is therefore biomechanically inferior. Regarding the immediate stability, a thicker screw should therefore be prioritised.


Assuntos
Osteoporose , Parafusos Pediculares , Humanos , Idoso de 80 Anos ou mais , Matriz Óssea , Osso e Ossos , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Fenômenos Biomecânicos , Cimentos Ósseos , Cadáver
17.
J Pers Med ; 13(1)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36675805

RESUMO

Purpose: The failure rate for operative decompression in neurogenic thoracic outlet syndrome (NTOS) is high compared to more distal nerve compression syndromes, such as cubital or carpal tunnel syndrome. Herein, we aimed to determine if a more radical approach, namely costovertebral exarticulation of the first rib, may improve the postoperative results in patients with NTOS. Methods: From October 2002 to December 2020, 105 operative decompressions in 95 patients were evaluated; in 10 cases, decompressions were performed bilaterally. We presented the clinical outcomes of 59 exarticulations compared to those of 46 conventional resections. Evaluation was performed at a minimum of one year post-operation using the DASH questionnaire. Results: The exarticulation group presented with significantly better clinical outcomes (two-sample t-test assuming unequal variances, p < 0.001). Conclusions: This study showed that significantly better results were obtained when exarticulation of the first rib was performed in patients with NTOS. This finding supports the hypothesis that, in certain cases, the proximal portion of the first rib plays a pivotal role in the pathogenesis of NTOS.

18.
Arch Orthop Trauma Surg ; 143(5): 2485-2491, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35635575

RESUMO

BACKGROUND: Complex proximal humeral fracture ranks among the most common fracture types, especially in elderly patients. In locked plate fixation of proximal humerus fractures, the calcar is deciding for screws providing further medial column support. To date, the biomechanical effect of the length of these calcar screws is not well known. The purpose of this study was to analyze the effect of long calcar screws on fresh frozen prefractured cadaveric specimens. METHODS: In the present biomechanical study, 8 pairs of cadaveric proximal humeri were fractured identically using a custom-made fracture simulator. ORIF was performed using a locking plate (PHILOS; Fa. Synthes). The specimens were tested in a biomechanical setup under increased axial load without any calcar screws installed, with short calcar screws and long calcar screws installed. Strain gages (4-wire-120 Ohm, Fa. Vishay) mounted on the locking plate were used to evaluate the fixation strain and to give an estimate for primary stability.. RESULTS: The measured strain of the locking plate without calcar screws (804,64 µm/m) at maximum load (200 N) was significantly higher than with short (619,07 µm/m; p = 0.02) or long calcar screws (527,31 µm/m; p = 0.007). Additionally, strain with short calcar screws was noticeably higher in comparison to long calcar screws (619,07 µm/m vs. 527,31 µm/m; p = 0.03). CONCLUSION: Use of calcar screws improves the stability of realistically impacted 3-part varus humeral fractures. Long calcar screws that are positioned as close as possible to the joint provide further primary stability compared to short calcar screws. LEVEL OF EVIDENCE: Basic science study.


Assuntos
Fixação Interna de Fraturas , Fraturas do Ombro , Humanos , Idoso , Parafusos Ósseos , Fraturas do Ombro/cirurgia , Úmero/cirurgia , Placas Ósseas , Cadáver , Fenômenos Biomecânicos
19.
Acta Chir Belg ; 123(6): 699-706, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36259265

RESUMO

BACKGROUND: Meckel's diverticula result from incomplete obliteration and regression of the omphaloenteric duct and are the most common congenital intestinal malformations. Many Meckel's diverticula remain asymptomatic and are discovered as incidental findings. They present a diagnostic challenge. METHODS: We report the case of a 35-year-old man who presented with an acute abdomen and ileus. Computed tomography of the abdomen showed a mechanical small bowel ileus. There was a calibre jump in the terminal ileum with a round endoluminal definable hyperdense structure of almost 2 cm in diameter. RESULTS: An exploratory laparoscopy was performed revealing an inflamed Meckel's diverticulum with impacted enterolith as the cause of the intestinal obstruction. CONCLUSION: In symptomatic Meckel's diverticula, haemorrhage and obstruction are the most common complications. The development of ileus due to a Meckel's diverticulum with an enterolith is considered extremely rare but should be taken into account.


Assuntos
Cavidade Abdominal , Íleus , Obstrução Intestinal , Divertículo Ileal , Masculino , Humanos , Adulto , Divertículo Ileal/diagnóstico , Divertículo Ileal/diagnóstico por imagem , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Íleus/diagnóstico por imagem , Íleus/etiologia , Íleus/cirurgia , Tomografia Computadorizada por Raios X
20.
Clin Biomech (Bristol, Avon) ; 101: 105867, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36584578

RESUMO

BACKGROUND: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. METHODS: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal-reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. FINDINGS: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. INTERPRETATION: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Prótese do Joelho , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Artrite Infecciosa/cirurgia , Reoperação/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...