Med Phys ; 51(2): 1217-1231, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37523268

RESUMO

BACKGROUND: Respiratory motion induces artifacts in reconstructed cardiac perfusion SPECT images. Correction for respiratory motion often relies on a respiratory signal describing the heart displacements during breathing. However, using external tracking devices to estimate respiratory signals can add cost and operational complications in a clinical setting. PURPOSE: We aim to develop a deep learning (DL) approach that uses only SPECT projection data for respiratory signal estimation. METHODS: A modified U-Net was implemented that takes temporally finely sampled SPECT sub-projection data (100 ms) as input. These sub-projections are obtained by reframing the 20-s list-mode data, resulting in 200 sub-projections, at each projection angle for each SPECT camera head. The network outputs a 200-time-point motion signal for each projection angle, which was later aggregated over all angles to give a full respiratory signal. The target signal for DL model training was from an external stereo-camera visual tracking system (VTS). In addition to comparing DL and VTS, we also included a data-driven approach based on the center-of-mass (CoM) strategy. This CoM method estimates respiratory signals by monitoring the axial changes of CoM for counts in the heart region of the sub-projections. We utilized 900 subjects with stress cardiac perfusion SPECT studies, with 302 subjects for testing and the remaining 598 subjects for training and validation. RESULTS: The Pearson's correlation coefficient between the DL respiratory signal and the reference VTS signal was 0.90, compared to 0.70 between the CoM signal and the reference. For respiratory motion correction on SPECT images, all VTS, DL, and CoM approaches partially de-blured the heart wall, resulting in a thinner wall thickness and increased recovered maximal image intensity within the wall, with VTS reducing blurring the most followed by the DL approach. Uptake quantification for the combined anterior and inferior segments of polar maps showed a mean absolute difference from the reference VTS of 1.7% for the DL method for patients with motion >12 mm, compared to 2.6% for the CoM method and 8.5% for no correction. CONCLUSION: We demonstrate the capability of a DL approach to estimate respiratory signal from SPECT projection data for cardiac perfusion imaging. Our results show that the DL based respiratory motion correction reduces artefacts and achieves similar regional quantification to that obtained using the stereo-camera VTS signals. This may enable fully automatic data-driven respiratory motion correction without relying on external motion tracking devices.


Assuntos
Aprendizado Profundo , Humanos , Tomografia Computadorizada de Emissão de Fóton Único , Coração/diagnóstico por imagem , Movimento (Física) , Perfusão , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Imagens de Fantasmas
2.
J Nucl Cardiol ; 30(6): 2427-2437, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37221409

RESUMO

BACKGROUND: The aim of this research was to asses perfusion-defect detection-accuracy by human observers as a function of reduced-counts for 3D Gaussian post-reconstruction filtering vs deep learning (DL) denoising to determine if there was improved performance with DL. METHODS: SPECT projection data of 156 normally interpreted patients were used for these studies. Half were altered to include hybrid perfusion defects with defect presence and location known. Ordered-subset expectation-maximization (OSEM) reconstruction was employed with the optional correction of attenuation (AC) and scatter (SC) in addition to distance-dependent resolution (RC). Count levels varied from full-counts (100%) to 6.25% of full-counts. The denoising strategies were previously optimized for defect detection using total perfusion deficit (TPD). Four medical physicist (PhD) and six physician (MD) observers rated the slices using a graphical user interface. Observer ratings were analyzed using the LABMRMC multi-reader, multi-case receiver-operating-characteristic (ROC) software to calculate and compare statistically the area-under-the-ROC-curves (AUCs). RESULTS: For the same count-level no statistically significant increase in AUCs for DL over Gaussian denoising was determined when counts were reduced to either the 25% or 12.5% of full-counts. The average AUC for full-count OSEM with solely RC and Gaussian filtering was lower than for the strategies with AC and SC, except for a reduction to 6.25% of full-counts, thus verifying the utility of employing AC and SC with RC. CONCLUSION: We did not find any indication that at the dose levels investigated and with the DL network employed, that DL denoising was superior in AUC to optimized 3D post-reconstruction Gaussian filtering.


Assuntos
Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Coração , Curva ROC , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos
3.
Med Phys ; 49(8): 5093-5106, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35526225

RESUMO

PURPOSE: Dual respiratory-cardiac gating reduces respiratory and cardiac motion blur in myocardial perfusion single-photon emission computed tomography (MP-SPECT). However, image noise is increased as detected counts are reduced in each dual gate (DG). We aim to develop a denoising method for dual gating MP-SPECT images using a 3D conditional generative adversarial network (cGAN). METHODS: Twenty extended cardiac-torso phantoms with various 99m Tc-sestamibi distributions, defect characteristics, and body and organ sizes were used in the simulation, modeling six respiratory and eight cardiac gates (CGs), that is, 48 DGs for ordered subset expectation maximization reconstruction. Twenty clinical 99m Tc-sestamibi SPECT/CT datasets were re-binned into 7 respiratory gates and 8 CGs, that is, 56 DGs for maximum likelihood expectation maximization reconstruction. We evaluated the use of (i) phantoms' own datasets (patient-specific denoising [PD]) or other phantoms' datasets (cross-patient denoising) for training; (ii) the CG or the static (non-gated [NG]) data as the training references for cGAN; and (iii) cGAN as compared to conventional 3D post-reconstruction filtering, cardiac gating methods, and convolutional neural network. Normalized mean squared error, noise as assessed by normalized standard deviation, spatial blurring measured as the full-width-at-half-maximum of left ventricular wall, ejection fraction, joint correlation histogram, and defect size were analyzed as metrics of image quality. RESULTS: Training using patients' own dataset is superior to conventional training based on other patients' data. Using CG image as training reference provides a better trade-off in terms of noise and image blur as compared to the use of NG. cGAN-CG-PD provides superior performance as compared to other denoising methods for all physical and diagnostic indices evaluated in both simulation and clinical studies. CONCLUSIONS: cGAN denoising is promising for dual gating MP-SPECT based on the metrics mentioned earlier.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Processamento de Imagem Assistida por Computador/métodos , Perfusão , Imagens de Fantasmas , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Med Phys ; 49(1): 282-294, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34859456

RESUMO

PURPOSE: The aim of this work was to revisit the data-driven approach of axial center-of-mass (COM) measurements to recover a surrogate respiratory signal from finely sampled (100 ms) single photon emission computed tomography (SPECT) projection data derived from list-mode acquisitions. METHODS: For our initial evaluation, we acquired list-mode projection data from an anthropomorphic cardiac phantom mounted on a Quasar respiratory motion platform simulating 15 mm amplitude respiratory motion. We also selected 302 consecutive patients (138 males, 164 females) with list-mode acquisitions, external respiratory motion tracking, and written consent to evaluate the clinical efficacy of our data-driven approach. Linear regression, Pearson's correlation coefficient (r), and standard error of the estimates (SEE) between the respiratory signals obtained with a visual tracking system (VTS) and COM measurements were calculated for individual projection data sets and for the patient group as a whole. Both the VTS- and COM-derived respiratory signals were used to estimate and correct respiratory motion. The reconstruction for six-degree of freedom rigid-body motion estimation was done in two ways: (1) using three iterations of ordered-subsets expectation-maximization (OSEM) with four subsets (16 projection angles per subset), or 12 iterations of maximum-likelihood expectation-maximization (MLEM). Respiratory motion compensation was done employing either OSEM with 16 subsets (four projection angles per subset) and five iterations or MLEM and 80 iterations, using the two respiratory estimates, respectively. Polar map quantification was also performed, calculating the percentage count difference (%Diff) between polar maps without and with respiratory motion included. Average % Diff was calculated in 17 segments (defined according to ASNC Guidelines). Paired t-tests were used to determine significance (p-values). RESULTS: The r-value calculated when comparing the VTS and COM respiratory signals varied widely between -0.01 and 0.96 with an average of 0.70, while the SEE varied between 0.80 and 6.48 mm with an average of 2.05 mm for our patient set, while the same values for the one anthropomorphic phantom acquisition are 0.91 and 1.11 mm, respectively. A comparison between the respiratory motion estimates for VTS and COM in the S-I direction yielded an r = 0.90 (0.94), and an SEE of 1.56 mm (1.20 mm) for OSEM (MLEM), respectively. Bland-Altman plots and calculated intraclass correlation coefficients also showed excellent agreement between the VTS and COM respiratory motion estimates. Average S-I respiratory estimates for the VTS (COM) were 9.04 (9.2 mm) and 9.01 mm (9.14 mm) for the OSEM and MLEM, respectively. The paired t-test approached significance when comparing VTS and COM estimated respiratory signals with p-values of 0.069 and 0.051 for OSEM and MLEM. The respiratory estimates from the anthropomorphic cardiac phantom experiment using the VTS (COM) were 12.62 (14.10 mm) and 12.55 mm (14.29 mm) for OSEM and MLEM, respectively. Polar map quantification yielded average % Diff consistently better when employing VTS-derived respiratory estimates to correct for respiration compared to the COM-derived estimates. CONCLUSIONS: The results indicate that our COM method has the potential to provide an automated data-driven correction of cardiac respiratory motion without the drawbacks of our VTS methodology. However, it is not generally equivalent to the VTS method in extent of correction.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada de Emissão de Fóton Único , Algoritmos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Perfusão , Imagens de Fantasmas
5.
J Nucl Cardiol ; 29(5): 2340-2349, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34282538

RESUMO

BACKGROUND: We previously developed a deep-learning (DL) network for image denoising in SPECT-myocardial perfusion imaging (MPI). Here we investigate whether this DL network can be utilized for improving detection of perfusion defects in standard-dose clinical acquisitions. METHODS: To quantify perfusion-defect detection accuracy, we conducted a receiver-operating characteristic (ROC) analysis on reconstructed images with and without processing by the DL network using a set of clinical SPECT-MPI data from 190 subjects. For perfusion-defect detection hybrid studies were used as ground truth, which were created from clinically normal studies with simulated realistic lesions inserted. We considered ordered-subset expectation-maximization (OSEM) reconstruction with corrections for attenuation, resolution, and scatter and with 3D Gaussian post-filtering. Total perfusion deficit (TPD) scores, computed by Quantitative Perfusion SPECT (QPS) software, were used to evaluate the reconstructed images. RESULTS: Compared to reconstruction with optimal Gaussian post-filtering (sigma = 1.2 voxels), further DL denoising increased the area under the ROC curve (AUC) from 0.80 to 0.88 (P-value < 10-4). For reconstruction with less Gaussian post-filtering (sigma = 0.8 voxels), thus better spatial resolution, DL denoising increased the AUC value from 0.78 to 0.86 (P-value < 10-4) and achieved better spatial resolution in reconstruction. CONCLUSIONS: DL denoising can effectively improve the detection of abnormal defects in standard-dose SPECT-MPI images over conventional reconstruction.


Assuntos
Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Curva ROC , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
Eur J Nucl Med Mol Imaging ; 48(11): 3457-3468, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33797598

RESUMO

PURPOSE: Reconstructed transaxial cardiac SPECT images need to be reoriented into standard short-axis slices for subsequent accurate processing and analysis. We proposed a novel deep-learning-based method for fully automatic reorientation of cardiac SPECT images and evaluated its performance on data from two clinical centers. METHODS: We used a convolutional neural network to predict the 6 rigid-body transformation parameters and a spatial transformation network was then implemented to apply these parameters on the input images for image reorientation. A novel compound loss function which balanced the parametric similarity and penalized discrepancy of the prediction and training dataset was utilized in the training stage. Data from a set of 322 patients underwent data augmentation to 6440 groups of images for the network training, and a dataset of 52 patients from the same center and 23 patients from another center were used for evaluation. Similarity of the 6 parameters was analyzed between the proposed and the manual methods. Polar maps were generated from the output images and the averaged count values of the 17 segments were computed from polar maps to evaluate the quantitative accuracy of the proposed method. RESULTS: All the testing patients achieved automatic reorientation successfully. Linear regression results showed the 6 predicted rigid parameters and the average count value of the 17 segments having good agreement with the reference manual method. No significant difference by paired t-test was noticed between the rigid parameters of our method and the manual method (p > 0.05). Average count values of the 17 segments show a smaller difference of the proposed and manual methods than those between the existing and manual methods. CONCLUSION: The results strongly indicate the feasibility of our method in accurate automatic cardiac SPECT reorientation. This deep-learning-based reorientation method has great promise for clinical application and warrants further investigation.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Redes Neurais de Computação , Tomografia Computadorizada de Emissão de Fóton Único
7.
J Nucl Cardiol ; 28(2): 624-637, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-31077073

RESUMO

BACKGROUND: In the ongoing efforts to reduce cardiac perfusion dose (injected radioactivity) for conventional SPECT/CT systems, we performed a human observer study to confirm our clinical model observer findings that iterative reconstruction employing OSEM (ordered-subset expectation-maximization) at 25% of the full dose (quarter-dose) has a similar performance for detection of hybrid cardiac perfusion defects as FBP at full dose. METHODS: One hundred and sixty-six patients, who underwent routine rest-stress Tc-99m sestamibi cardiac perfusion SPECT/CT imaging and clinically read as normally perfused, were included in the study. Ground truth was established by the normal read and the insertion of hybrid defects. In addition to the reconstruction of the 25% of full-dose data using OSEM with attenuation (AC), scatter (SC), and spatial resolution correction (RC), FBP and OSEM (with AC, SC, and RC) both at full dose (100%) were done. Both human observer and clinical model observer confidence scores were obtained to generate receiver operating characteristics (ROC) curves in a task-based image quality assessment. RESULTS: Average human observer AUC (area under the ROC curve) values of 0.725, 0.876, and 0.890 were obtained for FBP at full dose, OSEM at 25% of full dose, and OSEM at full dose, respectively. Both OSEM strategies were significantly better than FBP with P values of 0.003 and 0.01 respectively, while no significant difference was recorded between OSEM methods (P = 0.48). The clinical model observer results were 0.791, 0.822, and 0.879, respectively, for the same patient cases and processing strategies used in the human observer study. CONCLUSIONS: Cardiac perfusion SPECT/CT using OSEM reconstruction at 25% of full dose has AUCs larger than FBP and closer to those of full-dose OSEM when read by human observers, potentially replacing the higher dose studies during clinical reading.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
8.
Med Phys ; 48(1): 156-168, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33145782

RESUMO

PURPOSE: Post-reconstruction filtering is often applied for noise suppression due to limited data counts in myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT). We study a deep learning (DL) approach for denoising in conventional SPECT-MPI acquisitions, and investigate whether it can be more effective for improving the detectability of perfusion defects compared to traditional postfiltering. METHODS: Owing to the lack of ground truth in clinical studies, we adopt a noise-to-noise (N2N) training approach for denoising in SPECT-MPI images. We consider a coupled U-Net (CU-Net) structure which is designed to improve learning efficiency through feature map reuse. For network training we employ a bootstrap procedure to generate multiple noise realizations from list-mode clinical acquisitions. In the experiments we demonstrated the proposed approach on a set of 895 clinical studies, where the iterative OSEM algorithm with three-dimensional (3D) Gaussian postfiltering was used to reconstruct the images. We investigated the detection performance of perfusion defects in the reconstructed images using the non-prewhitening matched filter (NPWMF), evaluated the uniformity of left ventricular (LV) wall in terms of image intensity, and quantified the effect of smoothing on the spatial resolution of the reconstructed LV wall by using its full-width at half-maximum (FWHM). RESULTS: Compared to OSEM with Gaussian postfiltering, the DL denoised images with CU-Net significantly improved the detection performance of perfusion defects at all contrast levels (65%, 50%, 35%, and 20%). The signal-to-noise ratio (SNRD ) in the NPWMF output was increased on average by 8% over optimal Gaussian smoothing (P < 10-4 , paired t-test), while the inter-subject variability was greatly reduced. The CU-Net also outperformed a 3D nonlocal means (NLM) filter and a convolutional autoencoder (CAE) denoising network in terms of SNRD . In addition, the FWHM of the LV wall in the reconstructed images was varied by less than 1%. Furthermore, CU-Net also improved the detection performance when the images were processed with less post-reconstruction smoothing (a trade-off of increased noise for better LV resolution), with SNRD improved on average by 23%. CONCLUSIONS: The proposed DL with N2N training approach can yield additional noise suppression in SPECT-MPI images over conventional postfiltering. For perfusion defect detection, DL with CU-Net could outperform conventional 3D Gaussian filtering with optimal setting as well as NLM and CAE.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imagem de Perfusão do Miocárdio , Algoritmos , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Tomografia Computadorizada de Emissão de Fóton Único
9.
Med Phys ; 47(9): 4223-4232, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32583468

RESUMO

PURPOSE: Respiratory gating reduces respiratory blur in cardiac single photon emission computed tomography (SPECT). It can be implemented as three gating schemes: (a) equal amplitude-based gating (AG); (b) phase or time-based gating (TG); or (c) equal count-based gating (CG), that is, a variant of amplitude-based method. The goal of this study is to evaluate the effectiveness of these respiratory gating methods for patients with different respiratory patterns in myocardial perfusion SPECT. METHODS: We reviewed 1274 anonymized patient respiratory traces obtained via the Vicon motion-tracking system during their 99m Tc-sestamibi SPECT scans and grouped them into four breathing categories: (a) regular respiration (RR); (b) periodic respiration (PR); (c) respiration with apnea (AR); and (d) unclassified respiration (UR). For each respiratory pattern, 15 patients were randomly selected and their list-mode data were rebinned using the three gating schemes. A preliminary reconstruction was performed for each gate with the heart region segmented and registered to a reference gate to estimate the respiratory motion. A final reconstruction incorporating respiratory motion correction was done to get a final image set. The estimated respiratory motion, the full-width-at-half-maxima (FWHM) measured across the image intensity profile of the left ventricle wall, as well as the normalized standard deviation measured in a uniform cuboid region of the thorax were analyzed. RESULTS: There are 47.1%, 24.3%, 13.5%, and 15.1% RR, PR, AR, and UR patients, respectively, among the 1274 patients in this study. The differences among the three gating schemes in RR were smaller than other respiratory patterns. The AG and CG methods showed statistically larger motion estimation than TG particularly in the AR and PR patterns. Noise of AG varied more in different gates, especially for AR and UR patterns. CONCLUSION: More than half of the patients reviewed exhibited nonregular breathing patterns. Amplitude-based gating, that is, AG and CG, is a preferred gating method for such patterns and is a robust respiratory gating implementation method given the respiratory pattern of the patients is unknown before data acquisition. Phase gating is also a feasible option for regular respiratory pattern.


Assuntos
Coração , Tomografia Computadorizada de Emissão de Fóton Único , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas , Respiração
10.
IEEE Trans Med Imaging ; 39(9): 2893-2903, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32167887

RESUMO

Lowering the administered dose in SPECT myocardial perfusion imaging (MPI) has become an important clinical problem. In this study we investigate the potential benefit of applying a deep learning (DL) approach for suppressing the elevated imaging noise in low-dose SPECT-MPI studies. We adopt a supervised learning approach to train a neural network by using image pairs obtained from full-dose (target) and low-dose (input) acquisitions of the same patients. In the experiments, we made use of acquisitions from 1,052 subjects and demonstrated the approach for two commonly used reconstruction methods in clinical SPECT-MPI: 1) filtered backprojection (FBP), and 2) ordered-subsets expectation-maximization (OSEM) with corrections for attenuation, scatter and resolution. We evaluated the DL output for the clinical task of perfusion-defect detection at a number of successively reduced dose levels (1/2, 1/4, 1/8, 1/16 of full dose). The results indicate that the proposed DL approach can achieve substantial noise reduction and lead to improvement in the diagnostic accuracy of low-dose data. In particular, at 1/2 dose, DL yielded an area-under-the-ROC-curve (AUC) of 0.799, which is nearly identical to the AUC = 0.801 obtained by OSEM at full-dose ( p -value = 0.73); similar results were also obtained for FBP reconstruction. Moreover, even at 1/8 dose, DL achieved AUC = 0.770 for OSEM, which is above the AUC = 0.755 obtained at full-dose by FBP. These results indicate that, compared to conventional reconstruction filtering, DL denoising can allow for additional dose reduction without sacrificing the diagnostic accuracy in SPECT-MPI.


Assuntos
Imagem de Perfusão do Miocárdio , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Curva ROC , Tomografia Computadorizada de Emissão de Fóton Único
11.
J Nucl Cardiol ; 27(2): 562-572, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30406608

RESUMO

BACKGROUND: We previously optimized several reconstruction strategies in SPECT myocardial perfusion imaging (MPI) with low dose for perfusion-defect detection. Here we investigate whether reducing the administered activity can also maintain the diagnostic accuracy in evaluating cardiac function. METHODS: We quantified the myocardial motion in cardiac-gated stress 99m-Tc-sestamibi SPECT studies from 163 subjects acquired with full dose (29.8 ± 3.6 mCi), and evaluated the agreement of the obtained motion/thickening and ejection fraction (EF) measures at various reduced dose levels (uniform reduction or personalized dose) with that at full dose. We also quantified the detectability of abnormal motion via a receiver-operating characteristics (ROC) study. For reconstruction we considered both filtered backprojection (FBP) without correction for degradations, and iterative ordered-subsets expectation-maximization (OS-EM) with resolution, attenuation and scatter corrections. RESULTS: With dose level lowered to 25% of full dose, the obtained results on motion/thickening, EF and abnormal motion detection were statistically comparable to full dose in both reconstruction strategies, with Pearson's r > 0.9 for global motion measures between low dose and full dose. CONCLUSIONS: The administered activity could be reduced to 25% of full dose without degrading the function assessment performance. Low dose reconstruction optimized for perfusion-defect detection can be reasonable for function assessment in gated SPECT.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Perfusão , Curva ROC , Reprodutibilidade dos Testes , Espalhamento de Radiação , Tomografia Computadorizada por Raios X
12.
J Nucl Cardiol ; 27(2): 634-647, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30088195

RESUMO

BACKGROUND: Respiratory gating reduces motion blurring in cardiac SPECT. Here we aim to evaluate the performance of three respiratory gating strategies using a population of digital phantoms with known truth and clinical data. METHODS: We analytically simulated 60 projections for 10 XCAT phantoms with 99mTc-sestamibi distributions using three gating schemes: equal amplitude gating (AG), equal count gating (CG), and equal time gating (TG). Clinical list-mode data for 10 patients who underwent 99mTc-sestamibi scans were also processed using the 3 gating schemes. Reconstructed images in each gate were registered to a reference gate, averaged and reoriented to generate the polar plots. For simulations, image noise, relative difference (RD) of averaged count for each of the 17 segment, and relative defect size difference (RSD) were analyzed. For clinical data, image intensity profile and FWHM were measured across the left ventricle wall. RESULTS: For simulations, AG and CG methods showed significantly lower RD and RSD compared to TG, while noise variation was more non-uniform through different gates for AG. In the clinical study, AG and CG had smaller FWHM than TG. CONCLUSIONS: AG and CG methods show better performance for motion reduction and are recommended for clinical respiratory gating SPECT implementation.


Assuntos
Coração/diagnóstico por imagem , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Simulação por Computador , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/métodos , Tecnécio Tc 99m Sestamibi
13.
J Nucl Cardiol ; 27(1): 80-95, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-28432671

RESUMO

BACKGROUND: Respiratory motion can deteriorate image fidelity in cardiac perfusion SPECT. We determined the extent of respiratory motion, assessed its impact on image fidelity, and investigated the existence of gender differences, thereby examining the influence of respiratory motion in a large population of patients. METHODS: One thousand one hundred and three SPECT/CT patients underwent visual tracking of markers on their anterior surface during stress acquisition to track respiratory motion. The extent of motion was estimated by registration. Visual indicators of changes in cardiac slices with motion correction, and the correlation between the extent of motion with changes in segmental-counts were assessed. RESULTS: Respiratory motion in the head-to-feet direction was the largest component of motion, varying between 1.1 and 37.4 mm, and was statistically significantly higher (p = 0.002) for males than females. In 33.0% of the patients, motion estimates were larger than 10 mm. Patients progressively show more distinct visual changes with an increase in the extent of motion. The increase in segmental-count differences in the anterior, antero-lateral, and inferior segments correlated with the extent of motion. CONCLUSIONS: Respiratory motion correction diminished the artefactual reduction in anterior and inferior wall counts associated with respiratory motion. The extent of improvement was strongly related to the magnitude of motion.


Assuntos
Artefatos , Cardiopatias/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Mecânica Respiratória/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Compostos Radiofarmacêuticos , Fatores Sexuais , Tecnécio Tc 99m Sestamibi , Adulto Jovem
14.
Phys Med Biol ; 64(5): 055005, 2019 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-30650394

RESUMO

In cardiac SPECT perfusion imaging, cardiac motion can lead to motion blurring of anatomical detail and perfusion defects in the reconstructed myocardium. In this study, we investigated the potential benefit of cardiac motion correction for improving the detectability of perfusion defects. We considered a post-reconstruction motion correction (PMC) approach in which the image motion between two cardiac gates is obtained with optical flow estimation. In the experiments, we demonstrated the proposed post-reconstruction motion correction with optical flow estimation (PMC-OFE) approach on a set of clinical acquisitions from 194 subjects. We quantified the detectability of perfusion defects in the reconstructed images by using the total perfusion deficit scores, calculated by the clinical software tool QPS, and conducted a receiver-operating-characteristic (ROC) study to obtain the detection performance. Besides imaging with conventional standard dose, we also evaluated the approach for reduced dose SPECT imaging where the imaging dose was retrospectively reduced to 50%, 25%, and 12.5% of the standard dose. The proposed PMC-OFE approach achieved at each dose level higher area-under-the-ROC-curve (AUC) for perfusion defect detection than the traditional approach of using ungated data (Non-MC) (p -value < 0.05); in particular, with half dose, PMC-OFE achieved AUC = 0.813, which is comparable to Non-MC with standard dose (AUC = 0.795). Moreover, the proposed PMC-OFE approach also outperformed the 'Motion Frozen' (MF) method implemented in the clinical quantitative gated SPECT (QGS) software. In particular, at 25% and 12.5% of standard dose, the AUC values obtained by PMC-OFE are 0.788 and 0.779, respectively, compared to 0.758 and 0.731 for MF (p -value < 0.05).


Assuntos
Circulação Coronária , Coração/diagnóstico por imagem , Coração/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Movimento , Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC
15.
Med Phys ; 46(1): 116-126, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30407634

RESUMO

PURPOSE: Single-photon emission computed tomography (SPECT) is a noninvasive imaging modality, used in myocardial perfusion imaging. The challenges facing the majority of clinical SPECT systems are low sensitivity, poor resolution, and the relatively high radiation dose to the patient. New generation systems (GE Discovery, DSPECT) dedicated to cardiac imaging improve sensitivity by a factor of 5-8. This improvement can be used to decrease acquisition time and/or dose. However, in the case of ultra-low dose (~3 mCi) injections, acquisition times are still significantly long, taking 10-12 min. The purpose of this work is to investigate a new gamma camera design with 21 hemi-ellipsoid detectors each with a pinhole collimator for cardiac SPECT for further improvement in sensitivity and resolution and reduced patient exposures and imaging times. METHODS: To evaluate the resolution of our hemi-ellipsoid system, GATE Monte-Carlo simulations were performed on point-sources, rod-sources, and NCAT phantoms. For average full-width-half-maximum (FWHM) equivalence with base flat-detector, the pinhole-diameter for the curved hemi-ellipsoid detector was found to be 8.68 mm, an operating pinhole-diameter nominally expected to be ~3 times more sensitive than state-of-the-art systems. Rod-sources equally spaced within the region of interest were acquired with a 21-detector system and reconstructed with our multi-pinhole (MPH) iterative OSEM algorithm with collimator resolution recovery. The results were compared with the results of a state-of-the-art system (GE Discovery) available in the literature. The system was also evaluated using the mathematical anthropomorphic NCAT (NURBS-based Cardiac Torso; Segars et al. IEEE Trans Nucl Sci. 1999;46:503-506) phantom with a full (clinical)-dose acquisition (25 mCi) for 2 min and an ultra-low dose acquisition of 3 mCi for 5.44 min. The estimated left ventricle (LV) counts were compared with the available literature on a state-of-the-art system (DSPECT). FWHM of the LV wall on MPH-OSEM-reconstructed images with collimator resolution recovery was estimated. RESULTS: On acquired rod-sources, the average resolution (FWHM) after reconstruction with resolution recovery in the entire region of interest (ROI) for cardiac imaging was on the average 4.44 mm (±2.84), compared to 6.9 mm (±1 mm) reported for GE Discovery (Kennedy et al., J Nucl Cardiol. 2014:21:443-452). For NCAT studies, improved sensitivity allowed a full-dose (25 mCi) 2-min acquisition (Ell8.68mmFD) which yielded 3.79 M LV counts. This is ~3.35 times higher compared to 1.13 M LV counts acquired in 2 min for clinical full dose for state-of-the-art DSPECT. The increased sensitivity also allowed an ultra-low dose acquisition protocol (Ell8.68 mmULD), 3 mCi (eight times less injected dose) in 5.44 min. This ultra-low dose protocol yielded ~1.23 M LV counts which was comparable to the full-dose 2-min acquisition for DSPECT. The estimated NCAT average FWHM at the LV wall after 12 iterations of the OSEM reconstruction was 4.95 and 5.66 mm around the mid-short-axis slices for Ell8.68mmFD and Ell8.68mmULD, respectively. CONCLUSION: Our Monte-Carlo simulation studies and reconstruction suggest using (inverted wineglass sized) hemi-ellipsoid detectors with pinhole collimators can increase the sensitivity ~3.35 times over the new generation of dedicated cardiac SPECT systems, while also improving the reconstructed resolution for rod-sources with an average of 4.44 mm in region of interest. The extra sensitivity may be used for ultra-low dose imaging (3 mCi) at ~5.44 min for comparable clinical counts as state-of-the-art systems.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Razão Sinal-Ruído , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
16.
J Nucl Cardiol ; 26(5): 1526-1538, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30062470

RESUMO

BACKGROUND: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. METHODS: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. RESULTS: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. CONCLUSIONS: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Movimento , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Perfusão , Imagens de Fantasmas , Curva ROC , Doses de Radiação , Reprodutibilidade dos Testes , Respiração
17.
IEEE Trans Med Imaging ; 38(6): 1466-1476, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30530358

RESUMO

We propose a patient-specific ("personalized") approach for tailoring the injected activities to individual patients in order to achieve dose reduction in SPECT-myocardial perfusion imaging (MPI). First, we develop a strategy to determine the minimum dose levels required for each patient in a large set of clinical acquisitions (857 subjects) such that the reconstructed images are sufficiently similar to that obtained at conventional clinical dose. We then apply machine learning models to predict the required dose levels on an individual basis based on a set of patient attributes which include body measurements and various clinical variables. We demonstrate the personalized dose models for two commonly used reconstruction methods in clinical SPECT-MPI: 1) conventional filtered backprojection (FBP) with post-filtering and 2) ordered-subsets expectation-maximization (OS-EM) with corrections for attenuation, scatter and resolution, and evaluate their performance in perfusion-defect detection by using the clinical Quantitative Perfusion SPECT software package. The results indicate that the achieved dose reduction can vary greatly among individuals from their conventional clinical dose and that the personalized dose models can achieve further reduction on average compared with a global (non-patient specific) dose reduction approach. In particular, the average personalized dose level can be reduced to 58% and 54% of the full clinical dose, respectively, for FBP and OS-EM reconstruction, while without deteriorating the accuracy in perfusion-defect detection. Furthermore, with the average personalized dose further reduced to only 16% of full dose, OS-EM can still achieve a detection accuracy level comparable to that of FBP with full dose.


Assuntos
Aprendizado de Máquina , Imagem de Perfusão do Miocárdio/métodos , Medicina de Precisão/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Radioisótopos/administração & dosagem , Radiometria
18.
Med Phys ; 45(7): 2991-3000, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29679508

RESUMO

PURPOSE: Cardiac perfusion images in single-photon emission computed tomography (SPECT) can suffer from respiratory motion blur. We investigated a reconstruction approach for correcting respiratory motion in respiratory-binned acquisitions and assessed the benefit of this approach in both standard dose and reduced dose. METHODS: We modeled the acquired data from different respiratory bins by a joint probability distribution which was parameterized with respect to a common reference bin. The acquired data from all the respiratory bins were then utilized simultaneously for determining the source distribution in the reference bin using maximum a posteriori (MAP) estimation. We evaluated this approach with simulated imaging data and ten sets of clinical acquisitions, and compared it with a postreconstruction motion correction approach developed previously. We quantified the accuracy of the reconstruction results both at standard dose and with imaging dose reduced by 50% and 75%, respectively. RESULTS: The proposed motion-compensated reconstruction (MCR) approach led to improved reconstruction of the myocardium in terms of both noise level and LV wall resolution. Compared to traditional acquisition (without motion correction), the proposed approach reduced the mean squared error of the image intensity in the myocardium by 27.59%, 20.59%, and 12.05% at full, half-, and quarter dose, respectively; the LV resolution, quantified by the full width at half-maximum (FWHM), was improved by 17.34%, 14.35%, and 12.95% at full, half-, and quarter dose, respectively; in addition, the proposed approach also improved the perfusion defect detectability at both full dose and reduced dose. Furthermore, with motion correction, the reconstruction results obtained at half-dose were comparable to that obtained at full dose without correction. Similar improvements were also demonstrated in the clinical acquisitions at different dose levels. CONCLUSIONS: Respiratory motion correction in perfusion SPECT can improve the reconstruction of the myocardium at both standard and reduced dose. At half-dose, the results obtained with motion correction are comparable to that of traditional reconstruction obtained at full dose. MCR can be more accurate than postreconstruction correction.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Movimento , Doses de Radiação , Respiração , Tomografia Computadorizada de Emissão de Fóton Único/normas , Ventrículos do Coração/diagnóstico por imagem , Humanos , Padrões de Referência
19.
Br J Radiol ; 91(1081): 20160402, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27845567

RESUMO

Functional nuclear medicine imaging with single-photon emission CT (SPECT) in combination with anatomical CT has been commercially available since the beginning of this century. The combination of the two modalities has improved both the sensitivity and specificity of many clinical applications and CT in conjunction with SPECT that allows for spatial overlay of the SPECT data on good anatomy images. Introduction of diagnostic CT units as part of the SPECT/CT system has also potentially allowed for a more cost-efficient use of the equipment. Most of the SPECT systems available are based on the well-known Anger camera principle with NaI(Tl) as a scintillation material, parallel-hole collimators and multiple photomultiplier tubes, which, from the centroid of the scintillation light, determine the position of an event. Recently, solid-state detectors using cadmium-zinc-telluride became available and clinical SPECT cameras employing multiple pinhole collimators have been developed and introduced in the market. However, even if new systems become available with better hardware, the SPECT reconstruction will still be affected by photon attenuation and scatter and collimator response. Compensation for these effects is needed even for qualitative studies to avoid artefacts leading to false positives. This review highlights the recent progress for both new SPECT cameras systems as well as for various data-processing and compensation methods.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Neoplasias Ósseas/diagnóstico por imagem , Cádmio , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagem Multimodal , Imagem de Perfusão do Miocárdio , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Doses de Radiação , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Zinco
20.
Phys Med Biol ; 63(3): 035026, 2018 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-29283356

RESUMO

Cardiac gated images often suffer from increased noise in single photon emission computed tomography (SPECT) due to reduced data counts compared to non-gated studies. We investigate a spatiotemporal post-processing approach based on a non-local means (NLM) filter for suppressing the noise in gated SPECT images. In this filter, the output at a voxel location is computed from a weighted average of voxels in its four-dimensional (4D) neighborhood, wherein the filter coefficients are adjusted according to the similarity level in the local image pattern of individual voxels with respect to the output voxel. This adaptive property allows the filter to achieve noise reduction while avoiding excessive blur of the heart wall. In the experiments, we first evaluated the accuracy of the proposed NLM filtering approach using simulated SPECT imaging data. We then demonstrated the approach on eight sets of clinical acquisitions. In addition, we also explored the robustness of the NLM filter with imaging dose reduced by 50% in these clinical acquisitions. The quantitative results show that 4D NLM filtering could effectively reduce the noise level in gated images, leading to more accurate reconstruction of the myocardium. Compared to spatial filtering alone, using temporal filtering in NLM could reduce the mean-squared-error of the myocardium by 55.63% and improve the left ventricle resolution by 19.92%. It could also improve the visibility of perfusion defects in gated images. Similar results are also observed on the clinical acquisitions both at standard dose and at 50% reduced dose. The 4D NLM results are also found to be comparable to that of a motion-compensated 4D reconstruction approach which is computationally more demanding.


Assuntos
Algoritmos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/instrumentação , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Tomografia Computadorizada Quadridimensional/métodos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Humanos , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS