J Intensive Care Soc ; 25(2): 147-155, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38737313

RESUMO

Background: Despite high rates of cardiovascular disease in Scotland, the prevalence and outcomes of patients with cardiogenic shock are unknown. Methods: We undertook a prospective observational cohort study of consecutive patients with cardiogenic shock admitted to the intensive care unit (ICU) or coronary care unit at 13 hospitals in Scotland for a 6-month period. Denominator data from the Scottish Intensive Care Society Audit Group were used to estimate ICU prevalence; data for coronary care units were unavailable. We undertook multivariable logistic regression to identify factors associated with in-hospital mortality. Results: In total, 247 patients with cardiogenic shock were included. After exclusion of coronary care unit admissions, this comprised 3.0% of all ICU admissions during the study period (95% confidence interval [CI] 2.6%-3.5%). Aetiology was acute myocardial infarction (AMI) in 48%. The commonest vasoactive treatment was noradrenaline (56%) followed by adrenaline (46%) and dobutamine (40%). Mechanical circulatory support was used in 30%. Overall in-hospital mortality was 55%. After multivariable logistic regression, age (odds ratio [OR] 1.04, 95% CI 1.02-1.06), admission lactate (OR 1.10, 95% CI 1.05-1.19), Society for Cardiovascular Angiographic Intervention stage D or E at presentation (OR 2.16, 95% CI 1.10-4.29) and use of adrenaline (OR 2.73, 95% CI 1.40-5.40) were associated with mortality. Conclusions: In Scotland the prevalence of cardiogenic shock was 3% of all ICU admissions; more than half died prior to discharge. There was significant variation in treatment approaches, particularly with respect to vasoactive support strategy.

2.
Pain Med ; 10(1): 190-2, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18721173

RESUMO

OBJECTIVE: This case report outlines a significant type of morbidity due to continued use of gabapentin during an episode of acute renal failure. Setting. University teaching hospital. DISCUSSION: Gabapentin is widely used in the management of pain. It is entirely excreted through the renal system so this needs to be considered in any patient becoming acutely ill and developing renal failure. We describe a patient who developed significant deterioration in her conscious level due to iatrogenic gabapentin overdose. CONCLUSION: All doctors need to be aware of the need to review the indications for gabapentin use during periods of acute illness, especially with regard to renal impairment. Off-label use should be discouraged.


Assuntos
Injúria Renal Aguda/fisiopatologia , Aminas/efeitos adversos , Ácidos Cicloexanocarboxílicos/efeitos adversos , Ácido gama-Aminobutírico/efeitos adversos , Idoso , Aminas/uso terapêutico , Animais , Ácidos Cicloexanocarboxílicos/uso terapêutico , Feminino , Gabapentina , Humanos , Doença Iatrogênica , Dor/tratamento farmacológico , Ácido gama-Aminobutírico/uso terapêutico
3.
Crit Care Resusc ; 10(3): 209-16, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18798719

RESUMO

OBJECTIVE: To assess the accuracy of the Guardian REALTime continuous glucose monitoring system (Medtronic MiniMed, Northridge, Calif, USA) in critically ill adults compared with standard bedside point-of-care testing of capillary and arterial blood glucose levels. SETTING: An 18-bed mixed university tertiary referral intensive care unit, July to December 2006. MAIN OUTCOME MEASURES: Glucose measurements by the Guardian subcutaneous monitoring system were compared with simultaneous measurements of capillary and arterial blood glucose levels. Correlation between the different methods was determined by linear regression, using capillary blood glucose values as the "gold standard", and was further analysed by Bland and Altman plots. RESULTS: 17 emergency-admission mechanically ventilated adults were studied. A total of 1101 glucose measurements were available for analysis (from Guardian, 371; capillary blood samples, 373; and arterial blood samples, 357). With an a-priori acceptable difference of +/-1mmol/L, the Guardian system did not perform well enough to replace current methods of glucose measurement. There was also significant discrepancy between arterial and capillary blood glucose measurements. These common methods of intermittent blood glucose sampling are therefore not interchangeable. CONCLUSION: The Guardian REAL-Time continuous glucose monitoring system cannot replace current methods of blood glucose measurement at a glucose threshold of +/-1mmol/L. It may have role as an early warning detection system for hypo- or hyperglycaemia, but this needs to be evaluated in a prospective study of extremes of blood glucose levels in a critically ill population. Glucose measurements in arterial and capillary blood samples with a point-of-care glucometer also showed wide discrepancies.


Assuntos
Análise Química do Sangue/instrumentação , Glicemia/análise , Estado Terminal , Adulto , Idoso , Análise Química do Sangue/métodos , Eletrodos Implantados , Feminino , Humanos , Unidades de Terapia Intensiva , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Intensive Care Med ; 31(1): 142-5, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15565362

RESUMO

OBJECTIVE: To analyse agreement between two methods for blood glucose measurement in intensive care patients: capillary blood using a reagent strip and glucometer with arterial blood using a blood gas analyser. DESIGN AND SETTING: Prospective, single-centre, observational study in a 12-bed tertiary referral intensive care unit. MEASUREMENTS: Blood glucose levels were measured in consecutive patients using simultaneous measurements of capillary blood samples using glucometry and from a multi-electrode arterial blood gas analyser. An a priori subgroup of patients with tissue hypoperfusion was identified (defined as systolic blood pressure <90 mmHg or vasopressor dependency). A total of 493 paired measurements were obtained; 75 of these were from patients with systemic hypoperfusion. RESULTS: Overall, the mean difference (bias) was 0.12 mmol/l (2.15 mg/dl) and precision 0.77 mmol/l (13.8 mg/dl); 95% limits of agreement were -0.14 and 1.66 mmol/l (-2.5 and 29.8 mg/dl). In patients with systemic hypoperfusion the bias was 0.24 mmol/l (4.0 mg/dl) and precision 0.9 mmol/l (16.2 mg/dl); 95% limits of agreement -2.05 and 1.58 mmol/l (36.8 and 28.4 mg/dl). CONCLUSIONS: In a general population of intensive care patients, there is statistical agreement between blood glucose measured from capillary blood glucometry and arterial blood gas analysis. However, in patients with systemic hypoperfusion, the accuracy of agreement between these two measurement techniques may be such that that biochemical hypoglycaemia (<2.5 mmol/l, 44.9 mg/dl) may go undetected if used interchangeably.


Assuntos
Gasometria/métodos , Glicemia , Cuidados Críticos/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos