Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 17(13): 1559-1573, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986655

RESUMO

BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Insuficiência da Valva Mitral , Valva Mitral , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Idoso , Resultado do Tratamento , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fatores de Risco , Fatores de Tempo , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Medição de Risco
2.
Am J Cardiol ; 212: 118-126, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38036051

RESUMO

Given the expanding indications toward younger patients at lower surgical risk, transcatheter aortic valve replacement (TAVR) simplification and streamlining are gaining increasing importance. Patients who underwent TAVR from the year 2015 to 2020 were prospectively enrolled. The patients were divided in time tertiles according to the date of intervention. Data on preprocedural planning, including coronary computed tomography angiography (CCTA), procedures, and outcomes, were compared between the time tertiles. A total of 771 consecutive patients from a single institution were enrolled. We observed a trend toward the use of a fully percutaneous versus surgical approach for the index access, left radial artery versus contralateral femoral artery for the secondary access, and left ventricular pacing on the stiff guidewire versus right ventricular pacing. Immediate device success significantly increased, whereas the length of hospital stay decreased. Overall, approximately 60% of the total study population underwent CCTA instead of coronary angiography, with no adverse events. One-year survival rates significantly improved over time. A simplified TAVR approach was associated with better survival, whereas low baseline functional capacity, preexisting coronary artery disease, renal impairment, periprocedural blood transfusions, and paravalvular leak were related to worse outcomes. In conclusion, our study showed a constant tendency to procedure streamlining and improve procedural success and 1-year outcomes. A strategy based on CCTA allows sparing safely almost half of the preoperative invasive coronary angiography.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Angiografia Coronária , Estudos Retrospectivos
3.
Am J Cardiol ; 205: 241-248, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37611417

RESUMO

Symptoms of aortic stenosis (AS) are not proportional to its severity and patients with very severe AS (VSAS) remain asymptomatic for a long time. The appropriate time for intervention in patients with VSAS and the effects of transcatheter aortic valve implantation (TAVI) on left ventricular hypertrophy (LVH) remain debated. Our aim was to compare the procedural and 30-day outcomes of TAVI between patients with VSAS and patients with severe AS (SAS) and the changes in LVH. We selected patients with an aortic peak velocity ≥5 m/s (VSAS) and those with aortic peak velocity 4 to 5 m/s (SAS) treated with TAVI. Patients with reduced left ventricular ejection fraction (<45%) were excluded. The primary end point was the incidence of all-cause death at 30 days. The secondary end points included the 30-day incidence of cardiac death, cardiac rehospitalization, and stroke/transient ischemic attack and the changes in LVH from baseline to 30 days. A total of 102 patients in the VSAS group and 535 in the SAS group were included. Patients in the VSAS group had a thicker septal wall (p <0.001) and a higher Agaston score (p <0.001) and calcium volume (p = 0.007). No differences were observed regarding the primary and secondary clinical end points. However, patients with VSAS showed a significantly greater improvement in concentric LVH, although the prevalence of concentric LVH remained higher than in patients with SAS. TAVI in patients with VSAS showed similar procedural and clinical outcomes to patients with SAS and experienced a more pronounced improvement in the prevalence of concentric LVH.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Volume Sistólico , Função Ventricular Esquerda , Hipertrofia Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia
4.
Europace ; 25(3): 1116-1125, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36691737

RESUMO

AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estimulação Cardíaca Artificial/métodos , Resultado do Tratamento , Fatores de Risco , Doença do Sistema de Condução Cardíaco/etiologia , Eletrocardiografia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
5.
J Cardiovasc Med (Hagerstown) ; 23(12): 801-806, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36219144

RESUMO

AIMS: Local instead of general anesthesia has become the standard approach in many centers for transfemoral transcatheter aortic valve replacement (TAVR). New generation devices and an increase in operator skills had led to a drastic reduction in periprocedural complications, bringing in the adoption of a minimalist approach. In our study, we aimed to compare patients treated with TAVR under local anesthesia with or without the presence of an anesthesiologist on site (AOS). METHODS: We compare procedural aspects and results of patients treated with TAVR with an AOS against patients treated with TAVR with an anesthesiologist on call (AOC). From January 2019 to December 2020, all consecutive patients undergoing transfemoral TAVR with either the self-expandable Evolut (Medtronic, MN, USA) or balloon-expandable SAPIEN 3 (Edwards Lifesciences, CA, USA) were collected. RESULTS: Of 332 patients collected, 96 (29%) were treated with TAVR with AOS, while 236 (71%) were treated with TAVR with AOC. No differences in procedural time, fluoroscopy time and amount of contrast medium were observed. No procedural death and conversion to open-chest surgery was reported. The rate of stroke/transient ischemic attacks and major vascular complications was similar in the two groups. No patients in both groups required conversion to general anesthesia. Two patients (0.8%) in the AOC group required urgent intervention of the anesthesiologist. In the AOC group, there was a greater use of morphine (55.9% vs. 33.3%, P  = 0.008), but with a lower dose for each patient (2.0 vs. 2.8 mg, P  = 0.006). On the other hand, there was a lower use of other painkiller drugs (3.4% vs. 20.8%, P  = 0.001). No difference in inotropic drugs use was observed. CONCLUSION: In patients at low or intermediate risk undergoing transfemoral TAVR, a safe procedure can be performed under local anesthesia without the presence of an anesthesiologist in the catheterization laboratory.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Anestesiologistas , Desenho de Prótese , Resultado do Tratamento , Fluoroscopia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
6.
Nanomedicine ; 14(8): 2656-2665, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30010000

RESUMO

The 3-D spatial and mechanical features of nano-topography can create alternative environments, which influence cellular response. In this paper, murine fibroblast cells were grown on surfaces characterized by protruding nanotubes. Cells cultured on such nano-structured surface exhibit stronger cellular adhesion compared to control groups, but despite the fact that stronger adhesion is generally believed to promote cell cycle progression, the time cells spend in G1 phase is doubled. This apparent contradiction is solved by confocal microscopy analysis, which shows that the nano-topography inhibits actin stress fiber formation. In turn, this impairs RhoA activation, which is required to suppress the inhibition of cell cycle progression imposed by p21/p27. This finding suggests that the generation of stress fibers, required to impose the homeostatic intracellular tension, rather than cell adhesion/spreading is the limiting factor for cell cycle progression. Indeed, nano-topography could represent a unique tool to inhibit proliferation in adherent well-spread cells.


Assuntos
Adesão Celular , Ciclo Celular , Fibroblastos/fisiologia , Nanoestruturas/química , Animais , Divisão Celular , Células Cultivadas , Inibidor de Quinase Dependente de Ciclina p21/metabolismo , Fibroblastos/citologia , Camundongos , Alicerces Teciduais , Proteínas rho de Ligação ao GTP/metabolismo , Proteína rhoA de Ligação ao GTP
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...