Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomater Investig Dent ; 7(1): 80-85, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33015638

RESUMO

Purpose: By combining the increased toughness of a resin composite reinforced with discontinuous fibers and the surface wear resistance of a particulate filler composite (PFC), a bilayered composite technique was recently introduced. This study aimed to evaluate the effect of the thickness of the overlaying PFC placed over a fiber-reinforced composite (FRC) core, on the fracture-behavior of direct crown restorations. Methods: Six groups of posterior crown restorations (n = 8/group) were fabricated having a discontinuous FRC-core (everX Flow) and a layer of surface PFC (Essentia U) with various thicknesses (0.5, 1.0, 1.5, 2.0 mm), with the remaining thickness of the bilayered being 6 mm. Control groups were only made of PFC or FRC materials. Restorations were statically loaded until fracture. Failure-modes were visually examined. Data were analyzed using ANOVA (p = .05) and regression analysis. Results: The regression analysis showed that by decreasing the thickness of PFC layer, the load bearing capacity of restorations increased linearly (R2=0.7909). ANOVA revealed that crown restorations made only from everX Flow composite had significantly higher load-bearing capacities (3990 ± 331 N) (p < .05) among all the groups tested. With regard to the failure-mode analysis, crowns that had a FRC core material of everX Flow revealed delamination of the PFC surface composite from the core. Crowns which were made only of PFC i.e. with no fiber reinforcement, showed a crushing-like fracture pattern. Conclusions: Restorations combining a thick FRC-core and a thin surface layer of PFC (0.5-1 mm), displayed promising performance related to fracture-behavior and load-bearing capacity.

2.
Biomater Investig Dent ; 7(1): 1-8, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32010900

RESUMO

Aim: The purpose of this in vitro study was to determine the effects of different polishing protocols on the surface gloss (SG) of different commercial dental resin composites (RCs). Material and methods: A total of 147 block-shaped specimens (40 mm length × 10 mm width × 2 mm thick) were made from conventional RCs (G-aenial Ant. and Flo X), bulk-fill RC (Filtek Bulk Fill), fluoride-releasing RCs (BEAUTIFIL II, ACTIVA-Restorative) and discontinuous microfiber-reinforced RCs (Alert and everX Flow). Each group was subdivided into seven subgroups (n = 3), according to polishing protocol: Laboratory-machine polishing with different siliconcarbide paper grits (G1: 320) → (G2: 800) → (G3: 1200) → (G4: 2000) → (G5: 4000). Chairside-hand polishing using a series of Sof-Lex spiral (G6) and abrasive polishing points (G7). Glossmeter was used to determine the SG at 60° incidence angle. SG was measured before and after polishing. Three-dimensional (3 D) noncontact optical profilometer and scanning electron microscopy (SEM) analysis were performed. Data were analyzed using ANOVA (p = .05). Results: Significant differences in SG (ranged 3-93 GU) were found according to the type of polishing protocol and RC (p < .05). Specimens polished with 4000 grit paper showed the highest SG (93 GU) values among all the groups tested. Conclusions: The tested chairside-hand polishing protocols presented lower SG values than laboratory-machine polishing (4000 silicon paper grit) and unpolished surfaces.

3.
J Mech Behav Biomed Mater ; 101: 103444, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31561057

RESUMO

OBJECTIVE: The aim of this study was to evaluate the fracture-behavior of direct composite restorations made with two different composite-core materials. In addition, fracture toughness (FT), flexural strength (FS) and flexural modulus (FM) of tested composites were evaluated. METHODS: Twenty groups of posterior crown restorations were fabricated (n = 6/group). The groups were made of a 4-5 mm layer of composite-core materials (everX Flow and SDR Flow+) and covered by a 2 mm layer of conventional composite (G-aenial Anterior & Posterior, G-aenial Universal Injectable, Essentia, CeramX, Filtek Z500). Control groups were only made of conventional composites or composite-core materials. Crowns were statically loaded until fracture. Failure-modes were then visually examined. FT, FS and FM were determined for each tested composite (n = 6). RESULTS: ANOVA revealed that crown restorations made only from everX Flow composite had significantly higher load-bearing capacities (3866 ±â€¯263 N) (p < 0.05) among all the groups tested. No statistically significant differences were found in the load-bearing capacities between crowns made with different composite-core materials (p > 0.05). everX Flow exhibited the highest FT (2.8 MPa m1/2) and Z500 presented the highest FS values (197 MPa) (p < 0.05) among tested composites. With regard to the failure-mode analysis, crowns that had a fiber-reinforced core material of everX Flow revealed delaminating of surface conventional composite from the substructure layer. While in crowns that had a core material of SDR Flow+ or having only conventional composites with no fiber reinforcement, showed a crushing fracture pattern. CONCLUSION: Restorations combining a fiber-reinforced composite core and a surface layer of conventional composite, displayed promising performance related to fracture-behavior.


Assuntos
Coroas , Fenômenos Mecânicos , Materiais Dentários , Falha de Prótese
4.
Odontology ; 107(3): 342-352, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30617664

RESUMO

This study aimed to evaluate certain physical properties including surface wear of a new experimental short fiber-reinforced flowable resin composite (SFRC) in comparison with different commercial flowable bulk fill resin composites (SDR, Tetric EvoFlow Bulk Fill, Filtek Bulk Fill Flowable and Estelite Bulk Fill Flow). The following properties were examined according to ISO standard: flexural strength, flexural modulus, fracture toughness, water sorption, volumetric shrinkage, and depth of cure. Degree of conversion (DC%) was determined by FTIR spectrometry. A wear test was conducted with 15000 chewing cycles using a dual-axis chewing simulator. Wear depth was measured by a three-dimensional (3D) noncontact optical profilometer. Scanning electron microscopy was used to evaluate the microstructure of SFRC. Data were statistically analyzed with analysis of variance ANOVA (p = 0.05). SFRC exhibited the highest fracture toughness (2.8 MPa m1/2) and flexural strength (146.5 MPa) values (p < 0.05) and the greatest depth of cure (5 mm) and lowest wear depth (18.2 µm) among the flowable bulk fill materials tested. SDR showed the lowest volumetric shrinkage percentage (2.9%), while the other resin composites had comparable volumetric shrinkage values (p > 0.05). The new short fiber-reinforced flowable resin composite differed significantly in its measured fracture toughness compared to the tested flowable bulk fill resin composites.


Assuntos
Resinas Compostas , Materiais Dentários , Teste de Materiais , Polimerização , Propriedades de Superfície
5.
J Clin Exp Dent ; 9(12): e1408-e1417, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29410756

RESUMO

BACKGROUND: Fiber reinforced composite (FRC) is a promising class of material that gives clinicians alternative treatment options. There are many FRC products available in the market based on either glass or polyethylene fiber type. The aim of this study was to present a comparison between glass and polyethylene fiber reinforced composites based on available literature review. MATERIAL AND METHODS: A thorough literature search, with no limitation, was done up to June 2017. The range of relevant publications was surveyed using PubMed and Google Scholar. From the search results, articles related to our search terms were only considered. An assessment of these articles was done by two individuals in order to include only articles directly compare between glass and polyethylene FRCs. The search terms used were "fiber reinforced dental composites" and "glass and polyethylene fibers in dentistry". RESULTS: The search provided 276 titles. Full-text analysis was performed for 29 articles that met the inclusion criteria. Most were laboratory-based research with various test specimen designs prepared according to ISO standard or with extracted teeth and only three articles were clinical studies. Most of studies (n=23) found superior characteristics of glass FRCs over polyethylene FRCs. CONCLUSIONS: Significant reinforcement differences between commercial glass and polyethylene fiber reinforced composites were found. Key words:Fiber reinforced composite, glass fiber, polyethylene fiber.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...