Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 257: 116292, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38653014

RESUMO

We report the development and initial validation of a paper-based nucleic acid testing platform that integrates Loop-mediated isothermal amplification (LAMP) with clustered regularly interspaced short palindromic repeats (CRISPR) technology, referred to as PLACID (Paper-based LAMP-CRISPR Integrated Diagnostics). LAMP eliminates the need for thermal cycling, resulting in simplified instrumentation, and the CRISPR-associated protein (Cas 12a) system eliminates false positive signals from LAMP products, resulting in highly selective and sensitive assays. We optimized the assay to perform both amplification and detection entirely on paper, eliminating the need for complex fluid handling steps and lateral flow assay transfers. Additionally, we engineered a smartphone-operated system that includes a low-powered, non-contact IR heating chamber to actuate paper-based LAMP and CRISPR reactions and enable the detection of fluorescent signals from the paper. The platform demonstrates high specificity and sensitivity in detecting nucleic acid targets with a limit of detection of 50 copies/µL. We integrate an equipment-free sample preparation separation technology designed to streamline the preparation of crude samples prior to nucleic acid testing. The practical utility of our platform is demonstrated by the successful detection of spiked SARS-CoV-2 RNA fragments in saliva, E. Coli in soil, and pathogenic E. Coli in clinically fecal samples of infected patients. Furthermore, we demonstrate that the paper-based LAMP CRISPR chips employed in our assays possess a shelf life of several weeks, establishing them as viable candidates for on-site diagnostics.


Assuntos
Técnicas Biossensoriais , COVID-19 , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Papel , SARS-CoV-2 , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Humanos , Técnicas Biossensoriais/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Sistemas CRISPR-Cas/genética , Limite de Detecção , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas/genética , Desenho de Equipamento , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/instrumentação , Escherichia coli/genética , Escherichia coli/isolamento & purificação , Proteínas Associadas a CRISPR/genética , Smartphone
2.
Micromachines (Basel) ; 14(11)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-38004850

RESUMO

Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA's quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (VR) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method's consistency and reproducibility. The LFA assay's stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study's findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.

3.
Sensors (Basel) ; 23(19)2023 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-37837140

RESUMO

Molecular tests for infectious diseases and genetic anomalies, which account for significant global morbidity and mortality, are central to nucleic acid analysis. In this study, we present a digital droplet LAMP (ddLAMP) platform that offers a cost-effective and portable solution for such assays. Our approach integrates disposable 3D-printed droplet generator chips with a consumer smartphone equipped with a custom image analysis application for conducting ddLAMP assays, thereby eliminating the necessity for expensive and complicated photolithographic techniques, optical microscopes, or flow cytometers. Our 3D printing technique for microfluidic chips facilitates rapid chip fabrication in under 2 h, without the complications of photolithography or chip bonding. The platform's heating mechanism incorporates low-powered miniature heating blocks with dual resistive cartridges, ensuring rapid and accurate temperature modulation in a compact form. Instrumentation is further simplified by integrating miniaturized magnification and fluorescence optics with a smartphone camera. The fluorescence quantification benefits from our previously established RGB to CIE-xyY transformation, enhancing signal dynamic range. Performance assessment of our ddLAMP system revealed a limit of detection at 10 copies/µL, spanning a dynamic range up to 104 copies/µL. Notably, experimentally determined values of the fraction of positive droplets for varying DNA concentrations aligned with the anticipated exponential trend per Poisson statistics. Our holistic ddLAMP platform, inclusive of chip production, heating, and smartphone-based droplet evaluation, provides a refined method compatible with standard laboratory environments, alleviating the challenges of traditional photolithographic methods and intricate droplet microfluidics expertise.


Assuntos
Ácidos Nucleicos , Smartphone , Técnicas de Amplificação de Ácido Nucleico/métodos , Microfluídica/métodos
4.
Sensors (Basel) ; 23(18)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37765775

RESUMO

The ability to simultaneously heat and image samples using transmitted light is crucial for several biological applications. However, existing techniques such as heated stage microscopes, thermal cyclers equipped with imaging capabilities, or non-contact heating systems are often bulky, expensive, and complex. This work presents the development and characterization of a Miniaturized Optically-clear Thermal Enclosure (MOTE) system-an open-source, inexpensive, and low-powered modular system-capable of convectively heating samples while simultaneously imaging them with transmitted light. We develop and validate a computational fluid dynamics (CFD) model to design and optimize the heating chamber. The model simulates velocity and temperature profiles within the heating chamber for various chamber materials and sizes. The computational model yielded an optimal chamber dimension capable of achieving a stable temperature ranging from ambient to 95 °C with a spatial discrepancy of less than 1.5 °C, utilizing less than 8.5 W of power. The dual-functionality of the MOTE system, enabling synchronous heating and transmitted light imaging, was demonstrated through the successful execution of paper-based LAMP reactions to detect λ DNA samples in real-time down to 10 copies/µL of the target concentration. The MOTE system offers a promising and flexible platform for various applications, from molecular diagnostics to biochemical analyses, cell biology, genomics, and education.

5.
Front Chem ; 10: 1023602, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311416

RESUMO

Carbon dots are zero-dimensional nanomaterials that have garnered significant research interest due to their distinct optical properties, biocompatibility, low fabrication cost, and eco-friendliness. Recently, their light-to-heat conversion ability has led to several novel photothermal applications. In this minireview, we categorize and describe the photothermal application of carbon dots along with methods incorporated to enhance their photothermal efficiency. We also discuss the possible mechanisms by which the photothermal effect is realized in these carbon-based nanoparticles. Taken together, we hope to provide a comprehensive landscape highlighting several promising research directions for using carbon dots for photothermal applications.

6.
Biosensors (Basel) ; 12(8)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36005047

RESUMO

Stereolithography based 3D printing of microfluidics for prototyping has gained a lot of attention due to several advantages such as fast production, cost-effectiveness, and versatility over traditional photolithography-based microfabrication techniques. However, existing consumer focused SLA 3D printers struggle to fabricate functional microfluidic devices due to several challenges associated with micron-scale 3D printing. Here, we explore the origins and mechanism of the associated failure modes followed by presenting guidelines to overcome these challenges. The prescribed method works completely with existing consumer class inexpensive SLA printers without any modifications to reliably print PDMS cast microfluidic channels with channel sizes as low as ~75 µm and embedded channels with channel sizes as low ~200 µm. We developed a custom multi-resin formulation by incorporating Polyethylene glycol diacrylate (PEGDA) and Ethylene glycol polyether acrylate (EGPEA) as the monomer units to achieve micron sized printed features with tunable mechanical and optical properties. By incorporating multiple resins with different mechanical properties, we were able to achieve spatial control over the stiffness of the cured resin enabling us to incorporate both flexible and rigid components within a single 3D printed microfluidic chip. We demonstrate the utility of this technique by 3D printing an integrated pressure-actuated pneumatic valve (with flexible cured resin) in an otherwise rigid and clear microfluidic device that can be fabricated in a one-step process from a single CAD file. We also demonstrate the utility of this technique by integrating a fully functional finger-actuated microfluidic pump. The versatility and accessibility of the demonstrated fabrication method have the potential to reduce our reliance on expensive and time-consuming photolithographic techniques for microfluidic chip fabrication and thus drastically lowering our barrier to entry in microfluidics research.


Assuntos
Microfluídica , Estereolitografia , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Microtecnologia , Impressão Tridimensional
7.
Langmuir ; 38(32): 9863-9873, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35913402

RESUMO

Lateral flow assays and paper microfluidics have the potential to replace benchtop instrumented medical diagnostic systems with instrument-free systems that rely on passive transport of liquid through micro-porous paper substrates. Predicting the imbibition dynamics of liquid through dry paper substrates is mostly modeled through the Lucas-Washburn (LW) equations. However, the LW framework assumes that the fluid front exhibits a sharp boundary between the dry and wet phases across the liquid imbibition interface. Additionally, the relative humidity in the environment results in moisture trapped within the pores of the paper substrates as the paper attains an equilibrium with the ambient air. Here, we apply a two-phase transport framework based on Brooks and Corey's model to capture imbibition dynamics on partially saturated paper substrates. The model is experimentally validated and is then used to predict the liquid-paper imbibition dynamics in simulated environments with 1-70% relative humidity. The model was also used to determine the saturation gradient of liquid along the imbibition interface of the paper substrate. Insights from these studies enabled us to determine the mechanism of the liquid transport in partially saturated porous paper substrates. The model also enabled us to evaluate the optimal paper shapes and relative humidity of the environment that maximize imbibition rates and minimize imbibition front broadening. Finally, we evaluate the effect of moisture content of paper on the rate of paper-based biochemical reaction by amplifying a sequence of the SARS-CoV-2 RNA target via reverse transcriptase loop-mediated isothermal amplification. Taken together, this study provides some important guidelines to academic and applied researchers working in point-of-care diagnostics to develop paper-based testing platforms that are capable of functioning in a robust manner across multiple environmental conditions.


Assuntos
COVID-19 , RNA Viral , COVID-19/diagnóstico , Humanos , Umidade , Porosidade , SARS-CoV-2
8.
ACS Appl Mater Interfaces ; 12(38): 42711-42722, 2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32845602

RESUMO

We report a unique naturally derived activated carbon with optimally incorporated nitrogen functional groups and ultra-microporous structure to enable high CO2 adsorption capacity. The coprocessing of biomass (Citrus aurantium waste leaves) and microalgae (Spirulina) as the N-doping agent was investigated by probing the parameter space (biomass/microalgae weight ratio, reaction temperature, and reaction time) of hydrothermal carbonization and activation process (via the ZnCl2/CO2 activation) to generate hydrochars and activated carbons, respectively, with tunable nitrogen content and pore sizes. The central composite-based design of the experiment was applied to optimize the parameters of the prehydrothermal carbonization procedure resulting in the fabrication of N-enriched carbonaceous products with the highest possible mass yield and nitrogen content. The resulting hydrochars and activated carbon samples were characterized using elemental analysis, X-ray diffraction, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, field emission scanning electron microscopy, and Brunauer-Emmett-Teller surface area analysis. We observe that while N-doping and the activation process can individually enhance the CO2 adsorption capacity to some extent, it is the combined effect of the two processes that synergistically work to greatly increase the adsorption capacity of the N-doped activated carbon by an amount which is more than the sum of individual contributions. We analyze the origins of this synergy with both physical and chemical characterization techniques. The resulting naturally derived activated carbon demonstrates one of the highest CO2 adsorption capacities (8.43 mmol/g) with rapid adsorption kinetics and good selectivity and reusability.


Assuntos
Dióxido de Carbono/isolamento & purificação , Carbono/química , Citrus/química , Nitrogênio/química , Spirulina/química , Adsorção , Biomassa , Dióxido de Carbono/química , Tamanho da Partícula , Porosidade , Propriedades de Superfície
9.
Anal Chem ; 90(21): 12385-12389, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30272954

RESUMO

Smartphones have shown promise as an enabling technology for portable and distributed point-of-care diagnostic tests. The CMOS camera sensor can be used for detecting optical signals, including fluorescence for applications such as isothermal nucleic acid amplification tests. However, such analysis is typically limited mostly to end point detection of single targets. Here we present a smartphone-based image analysis pipeline that utilizes the CIE xyY (chromaticity-luminance) color space to measure the luminance (in lieu of RGB intensities) of fluorescent signals arising from nucleic acid amplification targets, with a discrimination sensitivity (ratio between the positive to negative signals), which is an order of magnitude more than traditional RGB intensity based analysis. Furthermore, the chromaticity part of the analysis enables reliable multiplexed detection of different targets labeled with spectrally separated fluorophores. We apply this chromaticity-luminance formulation to simultaneously detect Zika and chikungunya viral RNA via end point RT-LAMP (Reverse transcription Loop-Mediated isothermal amplification). We also show real time LAMP detection of Neisseria gonorrhoeae samples down to a copy number of 3.5 copies per 10 µL of reaction volume in our smartphone-operated portable LAMP box. Our chromaticity-luminance analysis is readily adaptable to other types of multiplexed fluorescence measurements using a smartphone camera.


Assuntos
Colorimetria , Fluorescência , Corantes Fluorescentes/química , Imagem Óptica , RNA Viral/análise , Smartphone , Vírus Chikungunya/química , Colorimetria/instrumentação , Imagem Óptica/instrumentação , Fotografação/instrumentação , Smartphone/instrumentação , Zika virus/química
10.
Analyst ; 143(8): 1924-1933, 2018 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-29620773

RESUMO

Loop-mediated isothermal amplification (LAMP), coupled with reverse transcription (RT), has become a popular technique for detection of viral RNA due to several desirable characteristics for use in point-of-care or low-resource settings. The large number of primers in LAMP (six per target) leads to an increased likelihood of primer dimer interactions, and the inner primers in particular are prone to formation of stable hairpin structures due to their length (typically 40-45 bases). Although primer dimers and hairpin structures are known features to avoid in nucleic acid amplification techniques, there is little quantitative information in literature regarding the impact of these structures on LAMP or RT-LAMP assays. In this study, we examine the impact of primer dimers and hairpins on previously published primer sets for dengue virus and yellow fever virus. We demonstrate that minor changes to the primers to eliminate amplifiable primer dimers and hairpins improves the performance of the assays when monitored in real time with intercalating dyes, and when monitoring a fluorescent endpoint using the QUASR technique. We also discuss the thermodynamic implications of these minor changes on the overall stability of amplifiable secondary structures, and we present a single thermodynamic parameter that can be correlated to the probability of non-specific amplification associated with LAMP primers.


Assuntos
Primers do DNA , Vírus da Dengue/genética , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/análise , Sequência de Bases , Transcrição Reversa , Sensibilidade e Especificidade
11.
Sci Rep ; 7: 44778, 2017 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-28317856

RESUMO

Current multiplexed diagnostics for Zika, dengue, and chikungunya viruses are situated outside the intersection of affordability, high performance, and suitability for use at the point-of-care in resource-limited settings. Consequently, insufficient diagnostic capabilities are a key limitation facing current Zika outbreak management strategies. Here we demonstrate highly sensitive and specific detection of Zika, chikungunya, and dengue viruses by coupling reverse-transcription loop-mediated isothermal amplification (RT-LAMP) with our recently developed quenching of unincorporated amplification signal reporters (QUASR) technique. We conduct reactions in a simple, inexpensive and portable "LAMP box" supplemented with a consumer class smartphone. The entire assembly can be powered by a 5 V USB source such as a USB power bank or solar panel. Our smartphone employs a novel algorithm utilizing chromaticity to analyze fluorescence signals, which improves the discrimination of positive/negative signals by 5-fold when compared to detection with traditional RGB intensity sensors or the naked eye. The ability to detect ZIKV directly from crude human sample matrices (blood, urine, and saliva) demonstrates our device's utility for widespread clinical deployment. Together, these advances enable our system to host the key components necessary to expand the use of nucleic acid amplification-based detection assays towards point-of-care settings where they are needed most.


Assuntos
Vírus Chikungunya/isolamento & purificação , Vírus da Dengue/isolamento & purificação , Técnicas e Procedimentos Diagnósticos , Smartphone , Zika virus/isolamento & purificação , Animais , Bioensaio , Chlorocebus aethiops , Primers do DNA/metabolismo , Humanos , Reação em Cadeia da Polimerase , RNA Viral/genética , Sensibilidade e Especificidade , Células Vero
12.
Methods Mol Biol ; 1571: 251-266, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28281261

RESUMO

Incredible progress continues to be made toward development of low-cost nucleic acid-based diagnostic solutions suitable for deployment in resource-limited settings. Detection components play a vitally important role in these systems, but have proven challenging to adapt for operation in a portable format. Here we describe efforts aimed at leveraging the capabilities of consumer-class smartphones as a convenient platform to enable detection of nucleic acid products associated with DNA amplification via the polymerase chain reaction (PCR). First, we show how fluorescence-based detection can be incorporated into a portable convective thermocycling system controlled by a smartphone app. Raw images captured by the phone's camera are processed to yield real-time amplification data comparable to benchtop instruments. Next, we leverage smartphone imaging to achieve label-free detection of PCR products by monitoring changes in electrochemical reactivity of embedded metal electrodes as the target DNA concentration increases during replication. These advancements make it possible to construct rugged inexpensive nucleic acid detection components that can be readily embedded in a variety of portable bioanalysis instruments.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Smartphone , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Processamento de Imagem Assistida por Computador/métodos , Estatística como Assunto/métodos , Interface Usuário-Computador , Fluxo de Trabalho
13.
Proc Natl Acad Sci U S A ; 114(6): 1275-1280, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28119504

RESUMO

Porous mineral formations near subsea alkaline hydrothermal vents embed microenvironments that make them potential hot spots for prebiotic biochemistry. But, synthesis of long-chain macromolecules needed to support higher-order functions in living systems (e.g., polypeptides, proteins, and nucleic acids) cannot occur without enrichment of chemical precursors before initiating polymerization, and identifying a suitable mechanism has become a key unanswered question in the origin of life. Here, we apply simulations and in situ experiments to show how 3D chaotic thermal convection-flows that naturally permeate hydrothermal pore networks-supplies a robust mechanism for focused accumulation at discrete targeted surface sites. This interfacial enrichment is synchronized with bulk homogenization of chemical species, yielding two distinct processes that are seemingly opposed yet synergistically combine to accelerate surface reaction kinetics by several orders of magnitude. Our results suggest that chaotic thermal convection may play a previously unappreciated role in mediating surface-catalyzed synthesis in the prebiotic milieu.


Assuntos
Fontes Hidrotermais , Origem da Vida , Adsorção , Aminoácidos/química , Temperatura Alta , Minerais/química , Modelos Teóricos
14.
Anal Chem ; 88(9): 4651-60, 2016 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-26898247

RESUMO

We introduce a portable biochemical analysis platform for rapid field deployment of nucleic acid-based diagnostics using consumer-class quadcopter drones. This approach exploits the ability to isothermally perform the polymerase chain reaction (PCR) with a single heater, enabling the system to be operated using standard 5 V USB sources that power mobile devices (via battery, solar, or hand crank action). Time-resolved fluorescence detection and quantification is achieved using a smartphone camera and integrated image analysis app. Standard sample preparation is enabled by leveraging the drone's motors as centrifuges via 3D printed snap-on attachments. These advancements make it possible to build a complete DNA/RNA analysis system at a cost of ∼$50 ($US). Our instrument is rugged and versatile, enabling pinpoint deployment of sophisticated diagnostics to distributed field sites. This capability is demonstrated by successful in-flight replication of Staphylococcus aureus and λ-phage DNA targets in under 20 min. The ability to perform rapid in-flight assays with smartphone connectivity eliminates delays between sample collection and analysis so that test results can be delivered in minutes, suggesting new possibilities for drone-based systems to function in broader and more sophisticated roles beyond cargo transport and imaging.


Assuntos
Dispositivos Lab-On-A-Chip , Ácidos Nucleicos/química , Smartphone , Telemedicina/instrumentação , Telemedicina/métodos , Bacteriófago lambda/química , DNA/análise , Smartphone/instrumentação , Staphylococcus aureus/química
15.
Anal Chem ; 85(21): 10536-41, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24083802

RESUMO

The ability of chaotic advection under microscale confinement to direct chemical processes along accelerated kinetic pathways has been recognized for some time. However, practical applications have been slow to emerge because optimal results are often counterintuitively achieved in flows that appear to possess undesirably high disorder. Here we present a 3D time-resolved analysis of polymerase chain reaction (PCR)-mediated DNA replication across a broad ensemble of geometric states. The resulting parametric map reveals an unexpectedly wide operating regime where reaction rates remain constant over 2 orders of magnitude of the Rayleigh number, encompassing virtually any realistic PCR condition (temperature, volume, gravitational alignment), a level of robustness previously thought unattainable in the convective format.


Assuntos
Replicação do DNA , Dinâmica não Linear , Cinética
16.
Lab Chip ; 12(23): 4946-54, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23044724

RESUMO

There is a need for innovative educational experiences that unify and reinforce fundamental principles at the interface between the physical, chemical, and life sciences. These experiences empower and excite students by helping them recognize how interdisciplinary knowledge can be applied to develop new products and technologies that benefit society. Microfluidics offers an incredibly versatile tool to address this need. Here we describe our efforts to create innovative hands-on activities that introduce chemical engineering students to molecular biology by challenging them to harness microscale natural convection phenomena to perform DNA replication via the polymerase chain reaction (PCR). Experimentally, we have constructed convective PCR stations incorporating a simple design for loading and mounting cylindrical microfluidic reactors between independently controlled thermal plates. A portable motion analysis microscope enables flow patterns inside the convective reactors to be directly visualized using fluorescent bead tracers. We have also developed a hands-on computational fluid dynamics (CFD) exercise based on modeling microscale thermal convection to identify optimal geometries for DNA replication. A cognitive assessment reveals that these activities strongly impact student learning in a positive way.


Assuntos
Replicação do DNA , Técnicas Analíticas Microfluídicas/instrumentação , Biologia Molecular/educação , Biologia Molecular/instrumentação , Movimento (Física) , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...