1.
Eur Radiol ; 13(9): 2147-54, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12819917

RESUMO

Detection and staging of pancreatic malignancies remains a challenge for radiologists. Considering the poor prognosis of pancreatic adenocarcinoma, accurate preoperative staging is the key to a possibly curative surgical treatment. Contrast-enhanced helical CT has been the most commonly used for evaluation of pancreatic cancer in many institutions, although it suffers from many limitations. With the fast pace of advances in multidetector CT (MDCT), and the beginning clinical implementation of 16-row scanners, improvements in spatial resolution in the z-axis with near-isotropic imaging provide exquisite multiplanar reconstructions of pancreatic anatomy. This article provides an overview of current MDCT technique and protocols for assessment of pancreatic adenocarcinoma, and describes new 3D-display methods for effective visualization of large data sets provided by MDCT.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Carcinoma Ductal Pancreático/patologia , Humanos , Estadiamento de Neoplasias , Neoplasias Pancreáticas/patologia , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas
2.
AJNR Am J Neuroradiol ; 24(1): 5-12, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12533319

RESUMO

BACKGROUND AND PURPOSE: Recent findings suggest that diffusion-weighted imaging might be an important adjunct to the diagnostic workup of disease processes in the spine, but physiological motion and the challenging magnetic environment make it difficult to perform reliable quantitative diffusion measurements. Multi-section line scan diffusion imaging of the spine was implemented and evaluated to provide quantitative diffusion measurements of vertebral bodies and intervertebral disks. METHODS: Line scan diffusion imaging of 12 healthy study participants and three patients with benign vertebral compression fractures was performed to assess the potential of line scan diffusion imaging of the spinal column. In a subgroup of six participants, multiple b-value (5-3005 s/mm(2)) images were obtained to test for multi-exponential signal decay. RESULTS: All images were diagnostic and of high quality. Mean diffusion values were (230 +/- 83) x 10(-6) mm(2)/s in the vertebral bodies, (1645 +/- 213) x 10(-6) mm(2)/s in the nuclei pulposi, (837 +/- 318) x 10(-6) mm(2)/s in the annuli fibrosi and ranged from 1019 x 10(-6) mm(2)/s to 1972 x 10(-6) mm(2)/s in benign compression fractures. The mean relative intra-participant variation of mean diffusivity among different vertebral segments (T10-L5) was 2.97%, whereas the relative difference in mean diffusivity among participants was 7.41% (P <.0001). The estimated measurement precision was <2%. A bi-exponential diffusion attenuation was found only in vertebral bodies. CONCLUSION: Line scan diffusion imaging is a robust and reliable method for imaging the spinal column. It does not suffer as strongly from susceptibility artifacts as does echo-planar imaging and is less susceptible to patient motion than are other multi-shot techniques. The different contributions from the water and fat fractions need to be considered in diffusion-weighted imaging of the vertebral bodies.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Fraturas da Coluna Vertebral/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Disco Intervertebral/patologia , Vértebras Lombares/lesões , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Vértebras Torácicas/lesões , Vértebras Torácicas/patologia
3.
Radiology ; 225(3): 759-65, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12461258

RESUMO

PURPOSE: To evaluate the utility of curved planar reformations compared with standard transverse images in the assessment of pancreatic tumors. MATERIALS AND METHODS: Forty-three patients suspected of having pancreatic tumors underwent contrast material-enhanced biphasic multi-detector row computed tomography (CT). Curved planar reformations were generated along the pancreatic duct, common bile duct, and major mesenteric vessels. Three blinded independent readers assessed the curved planar reformations and transverse images separately for the presence of tumor, resectability, and vascular involvement. The results were compared with those of a consensus panel who evaluated the curved planar reformations and transverse images together along with clinical data and surgical findings. RESULTS: Of 43 patients, 20 had pancreatic malignancies as judged by the consensus panel and proven at biopsy and/or clinical follow-up. For tumor detection, transverse images and curved planar reformations had an average sensitivity of 95.0% and 98.4% (P >.05), respectively, and an average specificity of 90.9% and 91.3% (P >.05), respectively. For tumor resectability, transverse images and curved planar reformations had an average sensitivity of 85.7% and 71.4% (P >.05), respectively, and an average specificity of 85.2% and 84.3% (P >.05), respectively. Average interpretation time was 6.4 minutes with transverse images and 4.1 minutes with curved planar reformations. CONCLUSION: Curved planar reformations are equivalent to transverse images in the detection of pancreatic tumors and determination of surgical resectability.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Radiology ; 224(3): 764-8, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12202711

RESUMO

PURPOSE: To assess the frequency of isoattenuating pancreatic adenocarcinoma with multi-detector row computed tomography (CT) and determine whether there are specific secondary signs that aid in detection. MATERIALS AND METHODS: Fifty-three patients with pancreatic adenocarcinoma underwent contrast material-enhanced biphasic multi-detector row CT with curved planar reformation. Tumors were initially deemed isoattenuating or hypoattenuating to normal pancreatic parenchyma on the basis of visual inspection, and the degree of attenuation was confirmed by calculating the mean attenuation differences between normal pancreatic parenchyma and tumor (tumor-pancreas contrast) during the pancreatic phase. Indirect signs of pancreatic tumor were tabulated in patients with an isoattenuating tumor. RESULTS: Of the 53 patients, six (11%) had isoattenuating tumors with a mean tumor-pancreas contrast of 9.25 HU +/- 11.3 during the pancreatic phase and 4.15 HU +/- 8.5 during the portal venous phase. The secondary signs of pancreatic tumor in these six patients included an interrupted pancreatic duct (n = 5), dilated biliary and pancreatic ducts (n = 1), atrophic distal pancreatic parenchyma (n = 3), and mass effect and/or convex contour abnormality (n = 3). The mean tumor-pancreas contrast for the remaining 47 patients was 74.76 HU +/- 35.61 during the pancreatic phase. CONCLUSION: With no visible tumor-pancreas contrast for isoattenuating tumors, indirect signs such as mass effect, atrophic distal parenchyma, and an interrupted duct sign are important indicators for the presence of tumor.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Magn Reson Med ; 48(1): 128-36, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12111940

RESUMO

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.


Assuntos
Imagem Ecoplanar/métodos , Encéfalo/anatomia & histologia , Humanos , Matemática , Modelos Teóricos
6.
J Magn Reson Imaging ; 15(4): 364-73, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11948825

RESUMO

PURPOSE: To compare and evaluate two novel diffusion-weighted sequences, based either on fast spin-echo (FSE) or interleaved echo-planar imaging (EPI) methods, as potential tools for investing spinal cord abnormalities. MATERIALS AND METHODS: Following recent improvements, both interleaved EPI (IEPI) and FSE techniques could be alternative approaches for rapid diffusion-weighted imaging (DWI). Therefore, a navigated diffusion-weighted multishot FSE sequence and a fat-suppressed navigated diffusion-weighted IEPI sequence with local shimming capabilities were tested. Both methods were compared in a consecutive series of five healthy volunteers and five patients with suspected intramedullary lesions. The sequences were graded qualitatively as either superior, inferior, or equal in quality, and also quantitatively by measuring the amount of ghosting artifacts in the background. Quantitative measurements of the diffusion coefficients within the spine were included. RESULTS: The overall image quality of IEPI was superior to FSE. Two out of five FSE scans were rated with poor image quality, whereas all IEPI scans were of sufficient quality. The ghosting levels ranged from approximately 3.3% to 6.2% for IEPI and from approximately 7.5% to 18.9% for FSE. Diffusion coefficients measured in healthy volunteers were similar for both IEPI and FSE, but showed higher fluctuations with the FSE technique. CONCLUSION: Despite potential advantages of FSE, the IEPI technique is preferable for DWI applications in the spinal cord.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Medula Espinal/anatomia & histologia , Difusão , Feminino , Humanos , Doenças da Medula Espinal/diagnóstico
7.
J Comput Assist Tomogr ; 26(2): 199-201, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11884774

RESUMO

Despite advances in the diagnosis and treatment of peripheral vascular occlusive disease, an ever-aging population continues to provide scores of new cases requiring medical care. While traditional angiography has been the mainstay of diagnosis for many years, newer, less invasive techniques such as CT angiography with three-dimensional reformation are rapidly establishing themselves as first-line diagnostic modalities. We present a case of severe left subclavian artery stenosis that demonstrates the utility of curved planar reformation in providing a concise visual summary of the pertinent anatomy and abnormalities.


Assuntos
Angiografia/métodos , Artéria Subclávia/diagnóstico por imagem , Constrição Patológica/diagnóstico , Constrição Patológica/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...