Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37213071

RESUMO

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients develop ventricular arrhythmias (VAs) responsive to anti-tachycardia pacing (ATP). However, VA episodes have not been characterized in accordance with the device therapy, and with the emergence of the subcutaneous implantable cardioverter defibrillator (S-ICD), the appropriate device prescription in ARVC remains unclear. Study aim was to characterize VA events in ARVC patients during follow-up in accordance with device therapy and elicit if certain parameters are predictive of specific VA events. METHODS AND RESULTS: This was a retrospective single-centre study utilizing prospectively collated registry data of ARVC patients with ICDs. Forty-six patients were included [54.0 ± 12.1 years old and 20 (43.5%) secondary prevention devices]. During a follow-up of 12.1 ± 6.9 years, 31 (67.4%) patients had VA events [n = 2, 6.5% ventricular fibrillation (VF), n = 14], 45.2% VT falling in VF zone resulting in ICD shock(s), n = 10, 32.3% VT resulting in ATP, and n = 5, 16.1% patients had both VT resulting in ATP and ICD shock(s). Lead failure rates were high (11/46, 23.9%). ATP was successful in 34.5% of patients. Severely impaired right ventricular (RV) function was an independent predictor of VT resulting in ATP (hazard ratio 16.80, 95% confidence interval 3.74-75.2; P < 0.001) with a high predictive accuracy (area under the curve 0.88, 95%CI 0.76-1.00; P < 0.001). CONCLUSION: VA event rates are high in ARVC patients with a majority having VT falling in the VF zone resulting in ICD shock(s). S-ICDs could be of benefit in most patients with ARVC with the absence of severely impaired RV function which has the potential to avoid consequences of the high burden of lead failure.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Função Ventricular Direita , Seguimentos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Arritmias Cardíacas/etiologia , Cardiomiopatias/complicações , Trifosfato de Adenosina , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...