1.
Phys Med Biol ; 53(3): 655-72, 2008 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-18199908

RESUMO

X-ray diffraction studies give material-specific information about biological tissue. Ideally, a large area, low noise, wide dynamic range digital x-ray detector is required for laboratory-based x-ray diffraction studies. The goal of this work is to introduce a novel imaging technology, the CMOS active pixel sensor (APS) that has the potential to fulfil all these requirements, and demonstrate its feasibility for coherent scatter imaging. A prototype CMOS APS has been included in an x-ray diffraction demonstration system. An industrial x-ray source with appropriate beam filtration is used to perform angle dispersive x-ray diffraction (ADXRD). Optimization of the experimental set-up is detailed including collimator options and detector operating parameters. Scatter signatures are measured for 11 different materials, covering three medical applications: breast cancer diagnosis, kidney stone identification and bone mineral density calculations. Scatter signatures are also recorded for three mixed samples of known composition. Results are verified using two independent models for predicting the APS scatter signature: (1) a linear systems model of the APS and (2) a linear superposition integral combining known monochromatic scatter signatures with the input polychromatic spectrum used in this case. Cross validation of experimental, modelled and literature results proves that APS are able to record biologically relevant scatter signatures. Coherent scatter signatures are sensitive to multiple materials present in a sample and provide a means to quantify composition. In the future, production of a bespoke APS imager for x-ray diffraction studies could enable simultaneous collection of the transmitted beam and scattered radiation in a laboratory-based coherent scatter system, making clinical transfer of the technique attainable.


Assuntos
Desenho Assistido por Computador , Processamento de Sinais Assistido por Computador/instrumentação , Difração de Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Transdutores , Difração de Raios X/métodos
2.
Phys Med Biol ; 52(16): 4993-5011, 2007 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-17671349

RESUMO

CCD (charged coupled device) and CMOS imaging technologies can be applied to thin tissue autoradiography as potential imaging alternatives to using conventional film. In this work, we compare two particular devices: a CCD operating in slow scan mode and a CMOS-based active pixel sensor, operating at near video rates. Both imaging sensors have been operated at room temperature using direct irradiation with images produced from calibrated microscales and radiolabelled tissue samples. We also compare these digital image sensor technologies with the use of conventional film. We show comparative results obtained with (14)C calibrated microscales and (35)S radiolabelled tissue sections. We also present the first results of (3)H images produced under direct irradiation of a CCD sensor operating at room temperature. Compared to film, silicon-based imaging technologies exhibit enhanced sensitivity, dynamic range and linearity.


Assuntos
Autorradiografia/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Radiometria/instrumentação , Transdutores , Autorradiografia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Temperatura