Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aust Crit Care ; 29(3): 132-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26920443

RESUMO

BACKGROUND: Tracheostomy cuff deflation is a necessary stage of the decannulation pathway, yet the optimal clinical indicators to guide successful cuff deflation are unknown. OBJECTIVES: The study aims were to identify (1) the proportion of patients tolerating continuous cuff deflation at first attempt; (2) the clinical observations associated with cuff deflation success or failure, including volume of above cuff secretions and (3) the predictive capacity of these observations within a heterogeneous cohort. METHODS: A retrospective review of 113 acutely tracheostomised patients with a subglottic suction tube in situ was conducted. RESULTS: Ninety-five percent of patients (n=107) achieved continuous cuff deflation on the first attempt. The clinical observations recorded as present in the 24h preceding cuff deflation included: (1) medical stability, (2) respiratory stability, (3) fraction of inspired oxygen ≤0.4, (4) tracheal suction ≤1-2 hourly, (5) sputum thin and easy to suction, (6) sputum clear or white, (7) ≥moderate cough strength, (8) above cuff secretions ≤1ml per hour and (9) alertness≥eyes open to voice. Using the presence of all 9 indicators as predictors of successful cuff deflation tolerance, specificity and positive predictive value were 100%, although sensitivity was only 77% and negative predictive value 19%. Refinement to a set of 3 clinically driven criteria (medical and respiratory stability, above cuff secretions ≤1ml/h) provided high specificity (100%), sensitivity (95%), positive predictive value (100%) and an improved negative predictive value (55%). CONCLUSIONS: Key criteria can help guide clinical decision-making on patient readiness for cuff deflation.


Assuntos
Extubação/métodos , Traqueostomia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cuidados Críticos/métodos , Tomada de Decisões , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
2.
Respir Care ; 61(5): 607-14, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26860399

RESUMO

BACKGROUND: Advancements in tracheostomy tube design now provide clinicians with a range of options to facilitate communication for individuals receiving ventilator assistance through a cuffed tube. Little is known about the impact of these modern design features on resistance to air flow. METHODS: We undertook a bench model test to measure pressure-flow characteristics and resistance of a range of tubes of similar outer diameter, including those enabling subglottic suction and speech. A constant inspiratory ± expiratory air flow was generated at increasing flows up to 150 L/min through each tube (with or without optional, mandatory, or interchangeable inner cannula). Driving pressures were measured, and resistance was calculated (cm H2O/L/s). RESULTS: Pressures changed with increasing flow (P < .001) and tube type (P < .001), with differing patterns of pressure change according to the type of tube (P < .001) and direction of air flow. The single-lumen reference tube encountered the lowest inspiratory and expiratory pressures compared with all double-lumen tubes (P < .001); placement of an optional inner cannula increased bidirectional tube resistance by a factor of 3. For a tube with interchangeable inner cannulas, the type of cannula altered pressure and resistance differently (P < .001); the speech cannula in particular amplified pressure-flow changes and increased tube resistance by more than a factor of 4. CONCLUSIONS: Tracheostomy tube type and inner cannula selection imposed differing pressures and resistance to air flow during inspiration and expiration. These differences may be important when selecting airway equipment or when setting parameters for monitoring, particularly for patients receiving supported ventilation or during the weaning process.


Assuntos
Intubação Intratraqueal/instrumentação , Traqueostomia/instrumentação , Resistência das Vias Respiratórias/fisiologia , Cânula , Desenho de Equipamento , Modelos Teóricos , Pressão , Trabalho Respiratório/fisiologia
3.
Clin Nutr ; 34(4): 572-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25245858

RESUMO

BACKGROUND & AIMS: The presence of a nasogastric tube (NGT) affects swallowing physiology but not function in healthy young adults. The swallowing mechanism changes with increasing age, therefore the impact of a NGT on swallowing in elderly individuals is likely to be different but is not yet known. The aims of this study were to determine the effects of NGTs of different diameter on (1) airway penetration-aspiration, (2) pharyngeal residue, and (3) pharyngeal transit, in older healthy subjects. METHODS: Randomized controlled crossover design. Healthy elderly volunteers underwent 3 modified barium swallow studies in which multiple diet and fluid consistencies were swallowed under the following conditions: (A) no NGT (control), (B) fine bore NGT, and (C) wide bore NGT. The control condition was assessed first to establish baseline swallowing function, then NGT order was randomly allocated. RESULTS: Of the 15 volunteers (median age 65 years, range 60-81) complete data sets were obtained for 9 (4 with allocation order ABC; 5 with ACB). Wide bore NGT data could not be obtained for 6 volunteers mainly due to tube intolerance. The presence of a NGT was associated with: (i) an increase in airway penetration-aspiration (fine bore NGT with serial liquid swallows and puree) (p < 0.01); (ii) increased pharyngeal residue (p < 0.05) in the pyriform sinus (fine bore NGT with puree); and in the valleculae (both fine and wide bore NGT with soft solids); and (iii) an increase in pharyngeal transit duration regardless of consistency (p < 0.01), with longest swallowing durations with the widest tube. CONCLUSIONS: NGT presence increases airway penetration-aspiration, pharyngeal residue and prolongs transit through the pharynx in older healthy individuals. Consideration of NGT impact on swallowing during concurrent oral and enteral feeding is recommended, with further systematic investigation required in elderly patients recovering from critical illness. Clinical trial registry Australia & New Zealand Clinical Trials Registry (ACTRN12613000577718).


Assuntos
Deglutição/fisiologia , Intubação Gastrointestinal/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Faringe/metabolismo , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...