Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 17(7): 893-5, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12375249

RESUMO

There is concern that modularity in a total hip arthroplasty system increases serum cobalt and chromium ion levels. This study measures the serum cobalt and chromium levels in patients with an Oxford Universal Hip (Corin, Cirencester, United Kingdom), which has a modular sliding mechanism; patients with a similarly manufactured hip with no sliding mechanism; and a control group. Loosening was excluded clinically and radiologically. Arthroplasty patients had statistically higher levels of serum cobalt and chromium than controls, but there was no significant difference in levels between the implanted groups.


Assuntos
Artroplastia de Quadril , Cromo/sangue , Cobalto/sangue , Humanos , Período Pós-Operatório
2.
J Bone Joint Surg Br ; 81(5): 783-9, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10530837

RESUMO

We determined the outcome of 56 'Oxford' unicompartmental replacements performed for anteromedial osteoarthritis of the knee between 1982 and 1987. Of these, 24 were in patients who had died without revision, one was lost to follow-up and two had been revised. Of the remaining 29 knees, 26 were examined clinically and radiologically, two were only examined clinically and one patient was contacted by telephone. The mean age of the patients was 80.3 years. At a mean follow-up of 11.4 years (10 to 14) the measurements of the knee score, range of movement and degree of deformity were not significantly different from those made one to two years after operation, except that the range of flexion had improved. Comparison of fluoroscopically-controlled radiographs at a similar interval of time showed no change in the appearance of the lateral compartments. The retained articular cartilage continued to function for ten or more years which suggests that anteromedial osteoarthritis may be considered as a focal disorder of the knee. This justifies continued efforts to develop methods of treatment which preserve intact joint structures.


Assuntos
Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Falha de Equipamento , Feminino , Fluoroscopia , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Medição da Dor , Período Pós-Operatório , Amplitude de Movimento Articular
3.
Acta Orthop Scand ; 70(6): 596-8, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10665725

RESUMO

The influence of operative technique on the formation of incomplete cement mantles in the sagittal plane has been rarely considered in the literature. In this article, we discuss the influence of the anatomy of the proximal femur on the formation of incomplete cement mantles and discuss how their incidence can be reduced by correct component positioning.


Assuntos
Cimentação , Fêmur/diagnóstico por imagem , Prótese de Quadril , Articulação do Quadril/diagnóstico por imagem , Humanos , Radiografia
4.
J Bone Joint Surg Br ; 80(6): 976-82, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9853488

RESUMO

Many designs of unicompartmental knee replacement show early and mid-term failure due to polyethylene wear. We studied the wear rate of congruent polyethylene meniscal bearings retrieved from failed Oxford unicompartmental knee replacements. We examined 16 bearings, 0.8 to 12.8 years after implantation, measuring their thickness and comparing it with that of 14 unused bearings. The mean rate of penetration, which included the effects of wear at both upper and lower surfaces, was 0.036 mm per year (maximum 0.08). Bearings as thin as 3.5 mm wore no faster than thicker models, but ten with evidence of impingement had greater wear. The six bearings with no impingement showed a mean rate of penetration of 0.01 mm per year. In unicompartmental knee replacement, careful implantation of fully congruous meniscal bearings can avoid failure due to polyethylene wear.


Assuntos
Artroplastia do Joelho/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Humanos , Prótese do Joelho/efeitos adversos , Meniscos Tibiais , Pessoa de Meia-Idade , Polietilenos , Falha de Prótese , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...