Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ther Apher Dial ; 21(2): 126-132, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28296256

RESUMO

Estimating glomerular filtration rate (GFR) in elderly patients is a problem, since they are poorly represented in studies developing GFR equations. Serum cystatin C is a better indicator of GFR than serum creatinine in elderly patients. Therefore the aim of our study was to compare frequently used serum cystatin C based GFR equations with a gold standard (51 CrEDTA clearance) in elderly chronic kidney disease (CKD) patients. 106 adult Caucasian patients, older than 65 years (58 women, 48 men; mean age 72.5 years), were included. In each patient 51 CrEDTA clearance, serum creatinine (IDMS traceable method) and serum cystatin C (immunonephelometric method) were determined. GFR was estimated using the Simple cystatin C, CKD-EPI cystatin C, CKD-EPI creatinine-cystatin C and BIS2 equation. Mean serum creatinine of our patients was 141.4 ± 41.5 µmol/L, mean serum cystatin C 1.79 ± 0.6 mg/L, mean 51 CrEDTA clearance was 52.2 ± 15.9 mL/min per 1.73 m2 . Statistically significant correlations between 51 CrEDTA clearance and all formulas were found (P < 0.0001). In the receiver operating characteristic (ROC) curve analysis (cut-off for GFR 45 mL/min per 1.73 m2 ) no significant differences in diagnostic accuracy between all the before mentioned equations were found. Bland-Altman analysis for the same cut-off showed that CKD-EPI creatinine-cystatin C and BIS2 equation underestimated and CKD-EPI cystatin C and Simple cystatin C equation overestimated measured GFR. All equations lacked precision. Analysis of ability to correctly predict patient's GFR below or above 45 mL/min per 1.73 m2 showed similar ability for all equations (P = 0.24-0.89). All equations are equally accurate for estimating GFR in elderly Caucasian CKD patients. For daily practice Simple cystatin C equation is most practical.


Assuntos
Cistatina C/sangue , Taxa de Filtração Glomerular/fisiologia , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/fisiopatologia , Idoso , Biomarcadores/sangue , Feminino , Humanos , Testes de Função Renal , Masculino , Reprodutibilidade dos Testes
2.
Kidney Blood Press Res ; 35(6): 649-54, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23095576

RESUMO

BACKGROUND: Serum cystatin C (SCC)-based formulas and the newer creatinine formula (the Chronic Kidney Disease Epidemiology Collaboration formula (CKD-EPI)) were proposed as improved glomerular filtration rate (GFR) markers. The aim of our study was to compare serum creatinine (SCr)-based and SCC-based equations against (51)Cr-EDTA clearance in patients with mildly to moderately impaired kidney function. METHODS: 255 adult Caucasian patients with chronic kidney disease (GFR 89-30 ml/min/1.73 m(2)) were enrolled. In each patient, (51)Cr-EDTA clearance, SCr and SCC were determined. GFR was calculated using the Cockcroft-Gault (C&G), Modification of Diet in Renal Disease (MDRD), CKD-EPI formulas and simple cystatin C formula (SCCF) (100/SCC). RESULTS: The receiver-operating characteristic curve analysis (cut-off for GFR 60 ml/min/1.73 m(2)) showed that the SCCF had a higher diagnostic accuracy than C&G but not than MDRD or CKD-EPI formulas. The Bland-Altman analysis for the same cut-off value showed that creatinine formulas underestimated and SCCF overestimated the measured GFR. Analysis of ability to correctly predict a patient's GFR <60 or >60 ml/min/1.73 m(2) showed the higher ability for the SCCF compared to all creatinine-based formulas. CONCLUSION: Our results indicate that the SCCF is a reliable marker of GFR and comparable to creatinine formulas including the CKD-EPI formula.


Assuntos
Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular/fisiologia , Testes de Função Renal/métodos , Rim/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Rim/patologia , Nefropatias/sangue , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Testes de Função Renal/normas , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Exp Diabetes Res ; 2012: 179849, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23008697

RESUMO

In clinical practice the glomerular filtration rate (GFR) is estimated from serum creatinine-based equations like the Cockcroft-Gault formula (C&G) and Modification of Diet in Renal Disease formula (MDRD). Recently, serum cystatin C-based equations, the newer creatinine formula (The Chronic Kidney Disease Epidemiology Collaboration formula (CKD-EPI)), and equation that use both serum creatinine and cystatin C (CKD-EPI creatinine & cystatin formula) were proposed as new GFR markers. Present study compares serum creatinine-based equations, combined (including both serum creatinine and cystatin C) equation, and serum simple cystatin C formula (100/serum cystatin C) against 51CrEDTA clearance in 113 adult overweight Caucasians with diabetes mellitus type 2 (DM2) and chronic kidney disease (CKD). The results of present study demonstrated that the simple cystatin C formula could be a useful tool for the evaluation of renal function in overweight patients with DM2 and impaired kidney function in daily clinical practice in hospital and especially in outpatients. Despite the advantages of the simple cystatin C formula, cystatin C-based equations cannot completely replace the "gold standard" for estimation of the GFR in a population of DM2 patients with CKD, but may contribute to a more accurate selection of patients requiring such invasive and costly procedures.


Assuntos
Cistatina C/sangue , Diabetes Mellitus Tipo 2/complicações , Nefropatias Diabéticas/fisiopatologia , Rim/fisiopatologia , Sobrepeso/complicações , Insuficiência Renal Crônica/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Biomarcadores/sangue , Índice de Massa Corporal , Creatinina/sangue , Nefropatias Diabéticas/diagnóstico , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Sensibilidade e Especificidade , Índice de Gravidade de Doença
4.
Ther Apher Dial ; 15(3): 261-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21624073

RESUMO

Despite the fact that the serum creatinine level is notoriously unreliable for the estimation of glomerular filtration rate (GFR) in the elderly, the serum creatinine concentration and serum creatinine-based formulas, such as the Modification of Diet in Renal Disease study equation (MDRD) are the most commonly used markers to estimate GFR. Recently, serum cystatin C-based formulas, the newer creatinine formula (the Chronic Kidney Disease Epidemiology Collaboration formula (CKD-EPI creatinine formula), and an equation that uses both serum creatinine and cystatin C (CKD-EPI creatinine and cystatin formula) were proposed as new GFR markers. The aim of our study was to compare the MDRD formula, CKD-EPI creatinine formula, CKD-EPI creatinine and cystatin formula, and simple cystatin C formula (100/serum cystatin C) against (51) Cr-EDTA clearance in the elderly. A total of 317 adult Caucasian patients aged >65 years were enrolled. In each patient, (51) Cr-EDTA clearance, serum creatinine, and serum cystatin C were determined, and the GFR was calculated using the MDRD formula, CKD-EPI formulas, and simple cystatin C formula. Statistically significant correlations between (51) Cr-EDTA clearance and all formulas were found. In the receiver operating characteristic (ROC) curve analysis with a cut-off of GFR 45 mL/min/1.73 m(2), a higher diagnostic accuracy was achieved with the equation that uses both serum creatinine and cystatin C (CKD-EPI creatinine and cystatin formula) than the MDRD formula (P < 0.013) or CKD-EPI creatinine formula (P < 0.01), but it was not higher than that achieved for the simple cystatin C formula (P = 0.335). Bland and Altman analysis for the same cut-off value showed that the creatinine formulas underestimated and the simple cystatin C formula overestimated measured GFR. All equations lacked precision. The accuracy within 30% of estimated (51) Cr-EDTA clearance values differ according to the stage of CKD. Analysis of the ability to correctly predict GFR below and above 45 mL/min/1.73 m(2) showed a high prediction for all formulas. Our results indicate that the simple cystatin C formula, which requires just one variable (serum cystatin C concentration), is a reliable marker of GFR in the elderly and comparable to the creatinine formulas, including the CKD-EPI formulas.


Assuntos
Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular , Nefropatias/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Ácido Edético , Feminino , Humanos , Nefropatias/fisiopatologia , Masculino , Valor Preditivo dos Testes
5.
Nephron Clin Pract ; 114(2): c118-26, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19887832

RESUMO

BACKGROUND: The present study, involving a large group of patients with chronic kidney disease (CKD), compares different serum cystatin C-based equations for prediction of the glomerular filtration rate (GFR). METHODS: A total of 592 adult patients with CKD were enrolled in the study. Serum cystatin C was determined in each patient by an immunonephelometric method. Their GFR was estimated using 5 equations based on serum cystatin C: (1) the Larsson formula, (2) the Hoek formula, (3) the Grubb formula, (4) the simple cystatin C formula (GFR = 100/cystatin C) and (5) our own cystatin C formula (GFR = 90.63 x cystatin C(-1.192)). The actual GFR was measured using (51)CrEDTA clearance. RESULTS: The mean (51)CrEDTA clearance was 47 ml/min/1.73 m(2); the mean serum cystatin C concentration was 2.68 mg/l. Receiver operating characteristic curve analysis (cutoff for GFR: 60 ml/min/ 1.73 m(2)) showed no difference between the cystatin C formulas with regard to diagnostic accuracy. All equations underestimated the measured GFR except the simple cystatin C formula, which slightly overestimated the measured GFR. All equations lacked precision. The ability to correctly estimate the patient's GFR was high for all equations (87.3-91.9%), except for the Larsson formula, with which 29.2% of subjects were misclassified. CONCLUSIONS: Our results indicate that all serum cystatin C-based equations, excluding the Larsson formula, are reliable markers of the GFR in patients with CKD, and for daily clinical practice the simplest formula (100/cystatin C) could be accurate enough for GFR estimation.


Assuntos
Cistatina C/sangue , Diagnóstico por Computador/métodos , Taxa de Filtração Glomerular , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Falência Renal Crônica/sangue , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Eslovênia/epidemiologia , Adulto Jovem
6.
Ren Fail ; 30(2): 181-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18300118

RESUMO

The estimation of the glomerular filtration rate (GFR) is an essential part of the evaluation of patients with chronic kidney disease (CKD). Recently, serum cystatin C has been proposed as a new endogenous marker of GFR. Authors compared serum creatinine, creatinine clearance calculated from Cockcroft and Gault formula and serum cystatin C against (51)CrEDTA clearance in 252 patients with CKD and GFR <90 mL/min/1.73 m(2). Analysis of correlations and diagnostic accuracy (receiver operating characteristic curves) of different GFR markers indicate that serum cystatin C is a more reliable marker of GFR in patients with CKD than serum creatinine.


Assuntos
Creatinina/sangue , Cistatinas/sangue , Taxa de Filtração Glomerular/fisiologia , Falência Renal Crônica/diagnóstico , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Coortes , Cistatina C , Progressão da Doença , Feminino , Seguimentos , Humanos , Falência Renal Crônica/sangue , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Probabilidade , Curva ROC , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fatores Sexuais
7.
Nephrol Dial Transplant ; 21(7): 1855-62, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16524933

RESUMO

BACKGROUND: Estimation of the glomerular filtration rate (GFR) is essential for the evaluation of patients with chronic kidney disease (CKD). Recently, serum cystatin C was proposed as a new endogenous marker of GFR and in our study its diagnostic accuracy was compared with that of other markers of GFR. METHODS: In this study, 164 patients with CKD stages 2-3 (GFR 30-89 ml/min/1.73 m2), who had performed 51Cr-labelled ethylenediaminetetra-acetic acid clearance, were enrolled. In each patient, serum creatinine and serum cystatin C were determined. Creatinine clearance was calculated using the Cockcroft-Gault (C&G) and the modification of diet in renal disease (MDRD) formulas. RESULTS: The mean 51CrEDTA clearance was 57 ml/min/1.73 m2, the mean serum creatinine 149 micromol/l and the mean serum cystatin C 1.74 mg/l. We found significant correlation between 51CrEDTA clearance and serum creatinine (R = -0.666), serum cystatin C (R = -0.792), reciprocal of serum creatinine (R = 0.628), reciprocal of serum cystatin C (R = 0.753) and calculated creatinine clearance from the formulas C&G (R = 0.515) and MDRD formulas (R = 0.716). The receiver operating characteristic (ROC) curve analysis (cut-off for GFR 60 ml/min/1.73 m2) showed that serum cystatin C had a significantly higher diagnostic accuracy than serum creatinine (P = 0.04) and calculated creatinine clearance from the C&G formula (P < 0.0001), though only in female patients. No difference in diagnostic accuracy was found between serum cystatin C and creatinine clearance calculated from the MDRD formula. CONCLUSIONS: Our results indicate that serum cystatin C is a reliable marker of GFR in patients with mildly to moderately impaired kidney function and has a higher diagnostic accuracy than serum creatinine and calculated creatinine clearance from the C&G formula in female patients.


Assuntos
Cistatinas/sangue , Nefropatias/diagnóstico , Rim/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Cromo/metabolismo , Creatinina/metabolismo , Cistatina C , Cistatinas/metabolismo , Ácido Edético/química , Feminino , Taxa de Filtração Glomerular , Humanos , Nefropatias/sangue , Nefropatias/metabolismo , Testes de Função Renal , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...