Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 63(15): 4144-4156, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38856508

RESUMO

We investigate terahertz time-domain spectroscopy using a low-noise dual-frequency-comb laser based on a single spatially multiplexed laser cavity. The laser cavity includes a reflective biprism, which enables generation of a pair of modelocked output pulse trains with slightly different repetition rates and highly correlated noise characteristics. These two pulse trains are used to generate the THz waves and detect them by equivalent time sampling. The laser is based on Yb:CALGO, operates at a nominal repetition rate of 1.18 GHz, and produces 110 mW per comb with 77 fs pulses around 1057 nm. We perform THz measurements with Fe-doped photoconductive antennas, operating these devices with gigahertz 1 µm lasers for the first time, to our knowledge, and obtain THz signal currents approximately as strong as those from reference measurements at 1.55 µm and 80 MHz. We investigate the influence of the laser's timing noise properties on THz measurements, showing that the laser's timing jitter is quantitatively explained by power-dependent shifts in center wavelength. We demonstrate reduction in noise by simple stabilization of the pump power and show up to 20 dB suppression in noise by the combination of shared pumping and shared cavity architecture. The laser's ultra-low-noise properties enable averaging of the THz waveform for repetition rate differences from 1 kHz to 22 kHz, resulting in a dynamic range of 55 dB when operating at 1 kHz and averaging for 2 s. We show that the obtained dynamic range is competitive and can be well explained by accounting for the measured optical delay range, integration time, as well as the measurement bandwidth dependence of the noise from transimpedance amplification. These results will help enable a new approach to high-resolution THz-TDS enabled by low-noise gigahertz dual-comb lasers.

2.
Opt Lett ; 49(7): 1766-1769, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560858

RESUMO

Dual-comb microscopy enables high-speed and high-precision optical sampling by simultaneously extracting both amplitude and phase information from the interference signals with frequency division multiplexing. In this Letter, we introduce a spatiotemporal encoding approach for dual-comb microscopy that overcomes previous limitations such as mechanical scanning, low sampling efficiency, and system complexity. By employing free-space angular-chirp-enhanced delay (FACED) and a low-noise single-cavity dual-comb laser, we achieve scan-less 3D imaging with nanometer precision and a 3D distance-imaging rate of 330 Hz, restricted only by the repetition rate difference of the dual-comb laser. Specifically, the FACED unit linearly arranges the laser beam into an array. A grating subsequently disperses this array transversely into lines, facilitating ultrafast spectroscopic applications that are 1-2 orders of magnitude quicker than traditional dual-comb methods. This spatiotemporal encoding also eases the stringent conditions on various dual-comb laser parameters, such as repetition rates, coherence, and stability. Through carefully designed experiments, we demonstrate that our scan-less system can measure 3D profiles of microfabricated structures at a rate of 7 million pixels per second. Our method significantly enhances measurement speed while maintaining high precision, using a compact light source. This advancement has the potential for broad applications, including phase imaging, surface topography, distance ranging, and spectroscopy.

3.
Opt Express ; 31(4): 6633-6648, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36823915

RESUMO

Single-cavity dual-combs comprise a rapidly emerging technology platform suitable for a wide range of applications like optical ranging, equivalent time sampling, and spectroscopy. However, it remains a challenging task to develop a dual-comb system that exhibits low relative frequency fluctuations to allow for comb line resolved measurements, while simultaneously offering high average power and short pulse durations. Here we combine a passively cooled and compact dual-comb solid-state oscillator with a pair of core-pumped Yb-fiber-based amplifiers in a master-oscillator power-amplifier (MOPA) architecture. The Yb:KYW oscillator operates at 250 MHz and uses polarization multiplexing for dual-comb generation. To the best of our knowledge, this is the first demonstration of a single-cavity dual-comb based on this gain material. As the pulse timing characteristics inherent to the oscillator are preserved in the amplification process, the proposed hybrid approach leverages the benefit of both the ultra-low noise solid-state laser and the advantages inherent to fiber amplifier systems such as straight-forward power scaling. The amplifier is optimized for minimal pulse broadening while still providing significant amplification and spectral broadening. We obtain around 1 W of power per output beam with pulses then compressed down to sub-90 fs using a simple grating compressor, while no pre-chirping or other dispersion management is needed. The full-width half-maximum (FWHM) of the radio-frequency comb teeth is 700 Hz for a measurement duration of 100 ms, which is much less than the typical repetition rate difference, making this passively stable source well-suited for indefinite coherent signal averaging via computational phase tracking.

4.
Opt Express ; 30(21): 37245-37260, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36258316

RESUMO

Long-distance ranging is a crucial tool for both industrial and scientific applications. Laser-based distance metrology offers unprecedented precision making it the ideal approach for many deployments. In particular, dual-comb ranging is favorable due to its inherently high precision and sampling rate. To make high-performance long-range dual-comb LiDAR more accessible by reducing both cost and complexity, here we demonstrate a fiber-based dual-comb LiDAR frontend combined with a free-running diode-pumped solid-state dual-comb laser that allows for sub-µm measurement precision while offering a theoretical ambiguity range of more than 200 km. Our system simultaneously measures distance with the role of each comb interchanged, thereby enabling Vernier-based determination of the number of ambiguity ranges. As a proof-of-principle experiment, we measure the distance to a moving target over more than 10 m with sub-µm precision and high update rate, corresponding to a relative precision of 10-7. For a static target at a similar distance, we achieve an instantaneous precision of 0.29 µm with an update time of 1.50 ms. With a longer averaging time of 200 ms, we reach a precision of around 33 nm, which corresponds to a relative precision of about 3·10-9 with a time-of-flight-based approach.

5.
Appl Phys B ; 128(2): 24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35125672

RESUMO

Semiconductor saturable absorber mirrors (SESAMs) have enabled a wide variety of modelocked laser systems, which makes measuring their nonlinear properties an important step in laser design. Here, we demonstrate complete characterization of SESAMs using an equivalent time sampling apparatus. The light source is a free-running dual-comb laser, which produces a pair of sub-150-fs modelocked laser outputs at 1051 nm from a single cavity. The average pulse repetition rate is 80.1 MHz, and the full time window is scanned at 240 Hz. Cross-correlation between the beams is used to calibrate the time axis of the measurements, and we use a non-collinear pump-probe geometry on the sample. The measurements enable fast and robust determination of all the nonlinear reflectivity and recovery time parameters of the devices from a single setup, and show good agreement with conventional nonlinear reflectivity measurements. We compare measurements to a rate equation model, showing good agreement up to high pulse fluence values and revealing that the samples tested exhibit a slightly slower recovery at higher fluence values. Lastly, we examine the polarization dependence of the reflectivity, revealing a reduced rollover if cross-polarized beams are used or if the sample is oriented optimally around the beam axis.

6.
Opt Express ; 29(22): 35735-35754, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34809002

RESUMO

We present a free-running 80-MHz dual-comb polarization-multiplexed solid-state laser which delivers 1.8 W of average power with 110-fs pulse duration per comb. With a high-sensitivity pump-probe setup, we apply this free-running dual-comb laser to picosecond ultrasonic measurements. The ultrasonic signatures in a semiconductor multi-quantum-well structure originating from the quantum wells and superlattice regions are revealed and discussed. We further demonstrate ultrasonic measurements on a thin-film metalized sample and compare these measurements to ones obtained with a pair of locked femtosecond lasers. Our data show that a free-running dual-comb laser is well-suited for picosecond ultrasonic measurements and thus it offers a significant reduction in complexity and cost for this widely adopted non-destructive testing technique.

7.
Opt Express ; 28(20): 30275-30288, 2020 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-33114910

RESUMO

Dual optical frequency combs are an appealing solution to many optical measurement techniques due to their high spectral and temporal resolution, high scanning speed, and lack of moving parts. However, industrial and field-deployable applications of such systems are limited due to a high-cost factor and intricacy in the experimental setups, which typically require a pair of locked femtosecond lasers. Here, we demonstrate a single oscillator which produces two mode-locked output beams with a stable repetition rate difference. We achieve this via inserting two 45°-cut birefringent crystals into the laser cavity, which introduces a repetition rate difference between the two polarization states of the cavity. To mode-lock both combs simultaneously, we use a semiconductor saturable absorber mirror (SESAM). We achieve two simultaneously operating combs at 1050 nm with 175-fs duration, 3.2-nJ pulses and an average power of 440 mW in each beam. The average repetition rate is 137 MHz, and we set the repetition rate difference to 1 kHz. This laser system, which is the first SESAM mode-locked femtosecond solid-state dual-comb source based on birefringent multiplexing, paves the way for portable and high-power femtosecond dual-combs with flexible repetition rate. To demonstrate the utility of the laser for applications, we perform asynchronous optical sampling (ASOPS) on semiconductor thin-film structures with the free-running laser system, revealing temporal dynamics from femtosecond to nanosecond time scales.

8.
Opt Express ; 27(6): 7886-7895, 2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-31052615

RESUMO

We present a scheme for correcting the spectral fluctuations of high-harmonic radiation. We show that the fluctuations of the extreme-ultraviolet (XUV) spectral power density can be predicted solely by monitoring the generating laser pulses; this method is in contrast with traditional balanced detection used in optical spectroscopy, where a replica of the signal is monitored. Such possibility emerges from a detailed investigation of high-harmonic generation (HHG) noise. We find that in a wide parameter range of the HHG process, the XUV fluctuations are dominated by a spectral blueshift, which is correlated to the near-infrared (NIR) driving laser intensity variation. Numerical simulations support our findings and suggest that non-adiabatic blueshift is the main source of XUV fluctuations. A straightforward post-processing of the XUV spectra allows for noise reduction and improved precision of attosecond transient absorption experiments. The technique is readily transferable to attosecond transient reflectivity and potentially to attosecond photoelectron spectroscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...