Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Cancer ; 88: 48-56, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29190506

RESUMO

BACKGROUND: Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. AIM: To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. METHODS: The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). RESULTS: All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. CONCLUSIONS: Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico , Mama/patologia , Detecção Precoce de Câncer/métodos , Idoso , Índice de Massa Corporal , Feminino , Humanos , Modelos Logísticos , Mamografia/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco , Reino Unido
2.
Eur J Radiol ; 94: 13-15, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28941754

RESUMO

PURPOSE: The aim of this study was to determine the features that make interval cancers apparent on the preceding screening mammogram and determine whether changes in the ways of performing the interval cancer review will affect the true interval cancer rate. MATERIALS AND METHODS: This study was approved by the clinical governance committee. Mammograms of women diagnosed with an interval cancer were included in the study if they had been allocated to either the "suspicious signs" group or "subtle signs" group, during the historic interval cancer review. Three radiologists, individually and blinded to the site of interval cancer, reviewed the mammograms and documented the presence, site, characteristics and classification of any abnormality. Findings were compared with the appearances of the abnormality at the site of subsequent cancer development by a different breast radiologist. The chi-squared test was used in the analysis of the results, seeking associations between recall concordance and cancer mammographic or histological characteristics. RESULTS: 111/590 interval cancers fulfilled the study inclusion criteria. In 17% of the cases none of the readers identified the relevant abnormality on the screening mammogram. 1/3 readers identified the relevant lesion in 22% of the cases, 2/3 readers in 28% of cases and all 3 readers in 33% of cases. The commonest unanimously recalled abnormality was microcalcification and the most challenging mammographic abnormality to detect was asymmetric density. We did not find any statistically significant association between recall concordance and time to interval cancer, position of lesion in the breast, breast density or cancer grade. CONCLUSION: Even the simple step of performing an independent blinded review of interval cancers reduces the rate of interval cancers classified as missed by up to 39%.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/métodos , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Calcinose/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Radiology ; 283(2): 371-380, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28287917

RESUMO

Purpose To assess whether individual reader performance with digital breast tomosynthesis (DBT) and two-dimensional (2D) mammography varies with number of years of experience or volume of 2D mammograms read. Materials and Methods After written informed consent was obtained, 8869 women (age range, 29-85 years; mean age, 56 years) were recruited into the TOMMY trial (A Comparison of Tomosynthesis with Digital Mammography in the UK National Health Service Breast Screening Program), an ethically approved, multicenter, multireader, retrospective reading study, between July 2011 and March 2013. Each case was read prospectively for clinical assessment and to establish ground truth. A retrospective reading data set of 7060 cases was created and randomly allocated for independent blinded review of (a) 2D mammograms, (b) DBT images and 2D mammograms, and (c) synthetic 2D mammograms and DBT images, without access to previous examinations. Readers (19 radiologists, three advanced practitioner radiographers, and two breast clinicians) who had 3-25 (median, 10) years of experience in the U.K. National Health Service Breast Screening Program and read 5000-13 000 (median, 8000) cases per annum were included in this study. Specificity was analyzed according to reader type and years and volume of experience, and then both specificity and sensitivity were analyzed by matched inference. The median duration of experience (10 years) was used as the cutoff point for comparison of reader performance. Results Specificity improved with the addition of DBT for all readers. This was significant for all staff groups (56% vs 68% and 49% vs 67% [P < .0001] for radiologists and advanced practitioner radiographers, respectively; 46% vs 55% [P = .02] for breast clinicians). Sensitivity was improved for 19 of 24 (79%) readers and was significantly higher for those with less than 10 years of experience (91% vs 86%; P = .03) and those with total mammographic experience of fewer than 80 000 cases (88% vs 86%; P = .03). Conclusion The addition of DBT to conventional 2D screening mammography improved specificity for all readers, but the gain in sensitivity was greater for readers with less than 10 years of experience.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Competência Clínica/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Variações Dependentes do Observador , Radiologistas/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Reino Unido/epidemiologia
4.
Health Technol Assess ; 19(4): i-xxv, 1-136, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25599513

RESUMO

BACKGROUND: Digital breast tomosynthesis (DBT) is a three-dimensional mammography technique with the potential to improve accuracy by improving differentiation between malignant and non-malignant lesions. OBJECTIVES: The objectives of the study were to compare the diagnostic accuracy of DBT in conjunction with two-dimensional (2D) mammography or synthetic 2D mammography, against standard 2D mammography and to determine if DBT improves the accuracy of detection of different types of lesions. STUDY POPULATION: Women (aged 47-73 years) recalled for further assessment after routine breast screening and women (aged 40-49 years) with moderate/high of risk of developing breast cancer attending annual mammography screening were recruited after giving written informed consent. INTERVENTION: All participants underwent a two-view 2D mammography of both breasts and two-view DBT imaging. Image-processing software generated a synthetic 2D mammogram from the DBT data sets. RETROSPECTIVE READING STUDY: In an independent blinded retrospective study, readers reviewed (1) 2D or (2) 2D + DBT or (3) synthetic 2D + DBT images for each case without access to original screening mammograms or prior examinations. Sensitivities and specificities were calculated for each reading arm and by subgroup analyses. RESULTS: Data were available for 7060 subjects comprising 6020 (1158 cancers) assessment cases and 1040 (two cancers) family history screening cases. Overall sensitivity was 87% [95% confidence interval (CI) 85% to 89%] for 2D only, 89% (95% CI 87% to 91%) for 2D + DBT and 88% (95% CI 86% to 90%) for synthetic 2D + DBT. The difference in sensitivity between 2D and 2D + DBT was of borderline significance (p = 0.07) and for synthetic 2D + DBT there was no significant difference (p = 0.6). Specificity was 58% (95% CI 56% to 60%) for 2D, 69% (95% CI 67% to 71%) for 2D + DBT and 71% (95% CI 69% to 73%) for synthetic 2D + DBT. Specificity was significantly higher in both DBT reading arms for all subgroups of age, density and dominant radiological feature (p < 0.001 all cases). In all reading arms, specificity tended to be lower for microcalcifications and higher for distortion/asymmetry. Comparing 2D + DBT to 2D alone, sensitivity was significantly higher: 93% versus 86% (p < 0.001) for invasive tumours of size 11-20 mm. Similarly, for breast density 50% or more, sensitivities were 93% versus 86% (p = 0.03); for grade 2 invasive tumours, sensitivities were 91% versus 87% (p = 0.01); where the dominant radiological feature was a mass, sensitivities were 92% and 89% (p = 0.04) For synthetic 2D + DBT, there was significantly (p = 0.006) higher sensitivity than 2D alone in invasive cancers of size 11-20 mm, with a sensitivity of 91%. CONCLUSIONS: The specificity of DBT and 2D was better than 2D alone but there was only marginal improvement in sensitivity. The performance of synthetic 2D appeared to be comparable to standard 2D. If these results were observed with screening cases, DBT and 2D mammography could benefit to the screening programme by reducing the number of women recalled unnecessarily, especially if a synthetic 2D mammogram were used to minimise radiation exposure. Further research is required into the feasibility of implementing DBT in a screening setting, prognostic modelling on outcomes and mortality, and comparison of 2D and synthetic 2D for different lesion types. STUDY REGISTRATION: Current Controlled Trials ISRCTN73467396. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 4. See the HTA programme website for further project information.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Imageamento Tridimensional/instrumentação , Mamografia/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...