J Diabetes Sci Technol ; 5(2): 380-7, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21527109

RESUMO

BACKGROUND: Since 1990, there has been significant research devoted toward development of a noninvasive physiological glucose sensor. In this article, we report on the use of optical polarimetry for the noninvasive measurement of physiological glucose concentration in the anterior chamber of the eye of New Zealand white (NZW) rabbits. METHOD: Measurements were acquired using a custom-designed laser-based optical polarimetry system in a total of seven NZW rabbits anesthetized using an isoflurane-only anesthesia protocol. Aqueous humor-based polarimetric measurements were obtained by coupling light through the anterior chamber of the eye. Blood glucose levels were first stabilized and then altered with intravenous dextrose and insulin administration and measured every 3-5 min with a standard glucometer and intermittently with a YSI 2300 glucose analyzer. Acquired polarimetric glucose signals are calibrated to measured blood glucose concentration. RESULTS: Based on a total of 41 data points, Clarke error grid analysis indicated 93% in zone A, 7% in zone B, and 0% in zones C and D, with reference concentrations between 93 and 521 mg/dl. Errors in prediction are shown to be related to gross movement of the rabbit during the procedures, incurring time-varying corneal birefringence effects that directly affect the measured polarimetric signal. These effects can be compensated for with appropriate design modifications. CONCLUSIONS: An optical polarimetry technique was used for in vivo physiological glucose monitoring. The technique demonstrated provides a basis for the development of a noninvasive polarimetric glucose monitor for home, personal, or hospital use.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Glicemia/análise , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Animais , Câmara Anterior/irrigação sanguínea , Humor Aquoso/metabolismo , Calibragem , Desenho de Equipamento , Lasers , Luz , Coelhos , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Opt Lett ; 29(10): 1108-10, 2004 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-15182001

RESUMO

Experimental results on resonantly excited second-harmonic generation (SHG) in a periodic ionically self-assembled monolayer (ISAM) film are reported. A double-layer guided-mode resonance filter (GMRF) structure is coated with 40 bilayers of pyrlium-based chi(2) ISAM thin film and excited with the fundamental of a Nd:YAG laser. Enhanced second-harmonic conversion in the ISAM film is achieved because of the local field enhancement associated with the fundamental resonating leaky mode. This method of SHG is particularly promising, as the ISAM films under investigation exhibit anomalous dispersion that may be applied for phase matching to improve nonlinear conversion efficiency.