Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(9)2023 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-37763767

RESUMO

Doppler findings of persistent reverse end-diastolic flow (PREDF) in a fetal middle cerebral artery (MCA) are a very rare sonographic finding and are a marker of poor fetal condition. This finding often leads to intrauterine fetal death or early neonatal death. Reverse end-diastolic flow in the middle cerebral artery is an advanced hemodynamic event. Fetal cerebral circulation normally has a high impedance; in the event of fetal hypoxemia, impedance decreases, resulting in the central redistribution of blood flow to vital organs, which maintains the oxygen delivery to the brain. Reverse flow in the middle cerebral arteries describes the loss of this autoregulatory process. PREDF is a sequence that occurs due to increased extracranial or intracranial pressure. Previous case reports mentioned intracranial hemorrhage, fetal growth restriction, fetal anemia, and fetal hepatic abnormalities as problems leading to PREDF. This condition presumably arises due to cerebral edema associated with severe hypoxemia. We reported Doppler findings of PREDF MCA in a 33-year-old female patient at 30 weeks gestation who was referred to the hospital with severe preeclampsia accompanied by fetal growth restriction and oligohydramnios. A cesarean section was performed due to severe preeclampsia and a low bishop score. Hypotheses on various etiologies and their association with intrauterine/neonatal death as well as the best management still require further investigation.


Assuntos
Morte Perinatal , Pré-Eclâmpsia , Recém-Nascido , Gravidez , Humanos , Feminino , Adulto , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiologia , Retardo do Crescimento Fetal , Cesárea , Morte Fetal , Ultrassonografia Pré-Natal/métodos , Velocidade do Fluxo Sanguíneo
2.
Vaccines (Basel) ; 11(3)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36992082

RESUMO

Satisfying the needs of the national immunization program requires maintaining diphtheria-tetanus-pertussis (DTP)-hepatitis B (HB)-Haemophilus influenza B (Hib) production. Therefore, new hepatitis B sources are needed. This study aimed to evaluate the immunogenicity of the DTP-HB-Hib vaccine (Bio Farma) that used a different source of hepatitis B. A prospective randomized, double-blind, bridging study was conducted. Subjects were divided into two groups with different batch numbers. Healthy infants 6-11 weeks of age at enrollment were immunized with three doses of the DTP-HB-Hib vaccine after a birth dose of hepatitis B vaccine. Blood samples were obtained prior to vaccination and 28 days after the third dose. Adverse events were recorded until 28 days after each dose. Of the 220 subjects, 205 (93.2%) completed the study protocol. The proportion of infants with anti-diphtheria and anti-tetanus titers ≥ 0.01 IU/mL was 100%, with anti-HBsAg titers ≥ 10 mIU/mL was 100%, and with Polyribosylribitol Phosphate-Tetanus Conjugate (PRP-TT) titers > 0.15 µg/mL was 96.1%. The pertussis response rate was 84.9%. No serious adverse events related to the study vaccine occurred. The three-dose DTP-HB-Hib vaccine (Bio Farma) is immunogenic, well tolerated, and suitable to replace licensed-equivalent vaccines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...