Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop J Sports Med ; 11(11): 23259671231213994, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38035215

RESUMO

Background: Fatty infiltration (FI) or atrophy alone has been found to be inaccurate in predicting shoulder function after repair of large-to-massive rotator cuff tears (L/MRCTs), especially when a diverse extent of FI and atrophy presents in multiple rotator cuff muscles. Purpose/Hypothesis: The Posterosuperior Tetralogy Scoring System (PS-Tetra Score), which integrates FI and atrophy, was proposed to predict shoulder function after surgery. It was hypothesized was that a PS-Tetra Score ≥3 would be a risk factor for poor shoulder function after repair of posterosuperior L/MRCTs and would possess greater diagnostic value than using isolated FI or atrophy of the supraspinatus (SSP) or infraspinatus (ISP). Study Design: Case-control study; Level of evidence, 3. Methods: A total of 187 arthroscopic repairs of posterosuperior L/MRCTs were reviewed. Magnetic resonance imaging evaluations were performed of FI and atrophy of the SSP and ISP, teres minor hypertrophy, tendon retraction, and acromiohumeral distance. A postoperative American Shoulder and Elbow Surgeons (ASES) score of 70 was used to subgroup patients according to shoulder function. Univariate and multivariate analyses were performed to determine the risk factors of poor shoulder function (ASES ≤70). The diagnostic values of different indicators for predicting shoulder function were evaluated. Results: In univariate analysis, female sex, higher Goutallier grade of the SSP and ISP, positive SSP tangent sign, and PS-Tetra Score ≥3 was significantly associated with ASES score ≤70, whereas in binary logistic regression analysis, a PS-Tetra Score ≥3 was the only significant risk factor for poor shoulder function. The occurrence rate of poor function in shoulders with a PS-Tetra Score of 0, 1, 2, 3, and 4 was 0% (0/52), 0% (0/52), 19.57% (9/46), 58.06% (18/31), and 83.33% (5/6), respectively. PS-Tetra Score ≥3 possessed higher crude agreement (87.70%), specificity (90.97%), positive predictive value (62.16%), and area under the receiver operating characteristic curve (0.814) than the other 3 indicators, with relatively high negative predictive value (94.00%) and moderate sensitivity (71.88%). Conclusion: PS-Tetra Score ≥3 was a risk factor of poor shoulder function after repair of posterosuperior L/MRCTs and possessed greater diagnostic value than using isolated FI or atrophy of SSP or ISP alone for predicting shoulder function.

2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(5): 526-532, 2023 May 15.
Artigo em Chinês | MEDLINE | ID: mdl-37190826

RESUMO

Objective: To review the research progress of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation, and provide a guide for further research on bone graft resorption. Methods: The relevant literature in recent years was extensively reviewed. The pathogenesis, classification, risk factors, clinical function impact, and management of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation were summarized. Results: Bone graft resorption is the common complication after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation. Stress shielding and poor blood supply may contribute to the occurrence of bone graft resorption. The absence of significant preoperative glenoid bone loss, open procedure, earlier graft healing may to be the risk factors for bone graft resorption. Various assessment methods and classification systems are used to evaluate the region and severity of bone graft resorption. Partial resorption may be considered as a natural glenoid remodeling process after the surgery, but severe and complete resorption is proved to be one of the reasons for failed procedures and there is no effective measure to prevent it, except for accepting revision surgery. Conclusion: The pathogenesis, risk factors, clinical function impact of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation has not been fully elucidated and there is a lack of effective management strategies, so further clinical and basic researches are needed.


Assuntos
Reabsorção Óssea , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Luxação do Ombro/etiologia , Luxação do Ombro/cirurgia , Instabilidade Articular/cirurgia , Reabsorção Óssea/complicações , Reabsorção Óssea/patologia , Transplante Ósseo , Recidiva
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(4): 391-397, 2023 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-37070303

RESUMO

Objective: To evaluate the effectiveness of tendon insertion medialized repair in treatment of large-to-massive rotator cuff tears (L/MRCT). Methods: The clinical and imaging data of 46 L/MRCT patients who underwent arthroscopic insertion medialized repair between October 2015 and June 2019 were retrospectively analyzed. There were 26 males and 20 females with an average age of 57.7 years (range, 40-75 years). There were 20 cases of large rotator cuff tears and 26 cases of massive rotator cuff tears. Preoperative imaging evaluation included fatty infiltration (Goutallier grade), tendon retraction (modified Patte grade), supraspinatus tangent sign, acromiohumeral distance (AHD), and postoperative medializaiton length and tendon integrity. The clinical outcome was evaluated by visual analogue scale (VAS) score, American Society for Shoulder and Elbow Surgery (ASES) score, shoulder range of motion (including anteflexion and elevation, lateral external, and internal rotation) and anteflexion and elevation muscle strength before and after operation. The patients were divided into two groups (the intact tendon group and the re-teared group) according to the integrity of the tendon after operation. According to the medializaiton length, the patients were divided into group A (medialization length ≤10 mm) and group B (medialization length >10 mm). The clinical function and imaging indexes of the patients were compared. Results: All patients were followed up 24-56 months, with an average of 31.8 months. At 1 year after operation, MRI showed that the medializaiton length of supraspinatus tendon was 5-15 mm, with an average of 10.26 mm, 33 cases in group A and 13 cases in group B. Eleven cases (23.91%) had re-teared, including 5 cases (45.45%) of Sugaya type Ⅳ and 6 cases (54.55%) of Sugaya type Ⅴ. At last follow-up, the VAS score, ASES score, shoulder anteflexion and elevation range of motion, lateral external rotation range of motion, and anteflexion and elevation muscle strength significantly improved when compared with those before operation ( P<0.05); there was no significant difference in internal rotation range of motion between pre- and post-operation ( P>0.05). The Goutallier grade and modified Patte grade of supraspinatus muscle in the re-teared group were significantly higher than those in the intact tendon group, and the AHD was significantly lower than that in the intact tendon group ( P<0.05). There was no significant difference in other baseline data between the two groups ( P>0.05). Except that the ASES score of the intact tendon group was significantly higher than that of the re-teared group ( P<0.05), there was no significant difference in the other postoperative clinical functional indicators between the two groups ( P>0.05). There was no significant difference in the incidence of re-tear, VAS score, ASES score, range of motion of shoulder joint, and anteflexion and elevation muscle strength between group A and group B ( P>0.05). Conclusion: Tendon insertion medialized repair may be useful in cases with L/MRCT, and shows good postoperative shoulder function. Neither tendon integrity nor medialization length shows apparent correlations with postoperative shoulder function.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Tendões , Ruptura/cirurgia , Articulação do Ombro/cirurgia , Artroscopia/métodos , Amplitude de Movimento Articular
4.
Front Bioeng Biotechnol ; 10: 903779, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36082169

RESUMO

Background: Insufficient blood supply results in unsatisfactory wound healing, especially for challenging wound repair such as diabetic wound defects. Regular exercise training brings a lot of benefits to cardiovascular fitness and metabolic health including attenuation of T2DM progression. Circulating extracellular vesicles (EVs) are postulated to carry a variety of signals involved in tissue crosstalk by their modified cargoes, representing novel mechanisms for the effects of exercise. Prominently, both acute and chronic aerobic exercise training can promote the release of exercise-induced cytokines and enhance the angiogenic function of circulating angiogenic cell-derived EVs. Methods: We investigated the possible angiogenesis potential of aerobic exercise-induced circulating EVs (EXE-EVs) on diabetic wound healing. Circulating EVs were isolated from the plasma of rats subjected to 4 weeks of moderate aerobic exercise or sedentariness 24 h after the last training session. The therapeutic effect of circulating EVs was evaluated in vitro by proliferation, migration, and tube formation assays of human umbilical vein endothelial cells (HUVECs), as well as in vivo by quantification of angiogenesis and cutaneous wound healing in diabetic rats. Results: The number of circulating EVs did not change significantly in exercised rats 24 h post-exercise in comparison with the sedentary rats. Nevertheless, EXE-EVs showed remarkable pro-angiogenic effect by augmenting proliferation, migration, and tube formation of HUVECs. Furthermore, the findings of animal experiments revealed that the EXE-EVs delivered by decellularized dermal matrix hydrogel (DDMH) could significantly promote the repair of skin defects through stimulating the regeneration of vascularized skin. Discussion: The present study is the first attempt to demonstrate that aerobic exercise-induced circulating EVs could be utilized as a cell-free therapy to activate angiogenesis and promote diabetic wound healing. Our findings suggest that EXE-EVs may stand for a potential strategy for diabetic soft tissue wound repair.

5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 35(4): 414-419, 2021 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-33855823

RESUMO

OBJECTIVE: To investigate the mid-term effect of lateral placement of bone graft on shoulder joint degeneration after modified arthroscopic Latarjet surgery with elastic fixation for recurrent anterior shoulder dislocation with an anterior glenoid bone defect. METHODS: According to the inclusion and exclusion criteria, 18 patients with recurrent anterior shoulder dislocation and anterior glenoid bone defect who received the modified arthroscopic Latarjet surgery with elastic fixation between January 2015 and November 2016 were enrolled in this study. There were 12 males and 6 females with an average age of 26.2 years (range, 19-37 years). The number of shoulder dislocation ranged from 4 to 30 times (mean, 8.8 times). The disease duration was 8-49 months (mean, 23.8 months). The mean anterior glenoid bone defect was 25.2% of the glenoid surface (range, 20%-29%). The mean preoperative Instability Severity Index Score (ISIS) was 7.6 (range, 7-10). According to Samilson-Prieto classification, the shoulder joint degeneration was rated as grade 0 in 13 cases, grade Ⅰ in 3 cases, and grade Ⅱ in 2 cases. Before and after operation, the visual analogue scale (VAS) score, American Society of Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, Rowe score, and shoulder mobility were used to evaluate the effectiveness. Imaging examination was performed to observe the shoulder joint degeneration, the position of the bone graft, and the postoperative shaping of the scapular glenoid. RESULTS: All patients were followed up 55-62 months, with an average of 59.6 months. There was no neurovascular injuries, infections, fixation-related and bone graft-related complications. No re-dislocation and revision occurred. All patients returned to normal life, 17 of whom returned to sport. The VAS score was significantly decreased and ASES, Walch-Duplay, and Rowe scores were significantly improved at last follow-up ( P<0.05). No significant difference was found in range of motion of forward flexion, abduction, lateral rotation at 90° abduction, internal rotation at 90° abduction, or lateral rotation at 0° between pre- and post-operation ( P>0.05). Three-dimensional CT showed that the centers of all bone grafts were between 3∶30 and 4∶30 (right shoulder) or between 7∶40 and 8∶20 (left shoulder) and no bone grafts were positioned superiorly or inferiorly in the glenoid En-face view. All bone grafts were positioned lateral to the scapular glenoid with an average distance of 3.5 mm (range, 2.3-4.6 mm) in cross-sectional imaging by CT. Compared with the preoperative Samilson-Prieto classification results, all cases showed no progression of shoulder joint degeneration at 36, 48 months and last follow-up. All bone grafts remodeled to a steady state within 24 months after operation. The bone graft and glenoid finally remodeled analogous to the shape of the intact glenoid in the En-face view and became flush with the glenoid rim, remodeling to a curved shape congruent to the humeral head in cross-sectional imaging by CT. The shape of the remodeled glenoid at last follow-up was not significantly different from that at 24 months after operation. CONCLUSION: The lateral placement of the bone graft during modified arthroscopic Latarjet surgery with elastic fixation do not accelerate the imaging changes of shoulder joint degeneration.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Adulto , Artroscopia , Feminino , Humanos , Masculino , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Luxação do Ombro/etiologia , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia
6.
Orthop J Sports Med ; 9(2): 2325967120958487, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33614806

RESUMO

BACKGROUND: Graft impingement is one of the main concerns in double-bundle anterior cruciate ligament reconstruction (DB-ACLR). Impingement between the anteromedial (AM) and posterolateral (PL) bundles has been postulated to cause graft deterioration or rerupture, but this has not been thoroughly investigated, and the interbundle impingement pressure (IIP) has not been well researched. PURPOSE: To determine the IIP between the AM and PL bundles in the native anterior cruciate ligament (ACL) and in DB-ACLR with individualized and nonindividualized double-tunnel placement. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 30 fresh-frozen, nonpaired, human cadaveric knees were randomly divided into 3 groups of 10 knees: native intact ACL (NI group), DB-ACLR tunnel placement using the preserved remnant procedure (individualized reconstruction) (PR group), and DB-ACLR tunnel placement using the bony landmark procedure (nonindividualized reconstruction) (BL group). Pressure sensors were inserted between the AM and PL bundles. The knee was moved passively from full extension to full flexion, and the IIP between the 2 ACL bundles was measured every 15°. Similarly, the impingement pressure was measured between the ACL and intercondylar roof and between the ACL and posterior cruciate ligament (PCL). RESULTS: No significant differences were found in the maximum, mean, or minimum ACL-roof and ACL-PCL impingement pressures among the 3 groups. The IIP significantly increased when the knee joint was flexed >120° in all 3 groups (P < .001). Compared with the other 2 groups, the BL group had significantly higher maximum and mean IIP throughout the range of knee movement (P < .001) and from maximum extension to 120° of flexion (P < .001). The BL group also had significantly higher minimum IIP than the other 2 groups when knee flexion was >120° (P < .001). No significant differences were seen in maximum, minimum, or mean IIP between the NI and PR groups. CONCLUSION: The PR procedure (individualized DB-ACLR) was more consistent with the interbundle biomechanical conditions of the native ACL, whereas the BL procedure (nonindividualized DB-ACLR) had higher maximum and mean IIP. The IIP was higher than the ACL-intercondylar roof or ACL-PCL pressures, and it increased significantly when knee flexion was >120°. CLINICAL RELEVANCE: These data suggest that surgeons can perform individualized DB-ACLR using preserved remnants for tunnel placement as impingement-free DB-ACLR.

7.
Orthop J Sports Med ; 9(12): 23259671211063844, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34988238

RESUMO

BACKGROUND: It is unclear whether coracoacromial ligament release during the Latarjet procedure will increase superior translation of the shoulder joint. PURPOSE: To evaluate whether a modified suture button Latarjet procedure can decrease the acromiohumeral distance (AHD). STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A retrospective analysis was conducted among 155 patients who underwent a modified suture button Latarjet procedure between 2013 and 2015. AHD was measured on bilateral computed tomography scans taken preoperatively and on scans of the affected shoulder taken on postoperative day 1 and postoperative month (POM) 6, POM 36, and POM 60. At each time point, we recorded pain on a visual analog scale (VAS) and objective shoulder function using the American Shoulder and Elbow Surgeons, Rowe, and Walch-Duplay scores. Preoperative and final follow-up VAS and functional scores were compared using the paired t test. Pairwise comparison of AHD values at each follow-up time point were compared with the preoperative intact side using the paired t test. Intra- and interobserver reproducibility of the AHD measurements was evaluated using the intraclass correlation coefficient. RESULTS: A total of 104 patients who met the criteria completed the final follow-up, which occurred at 62.6 ± 2.4 months (mean ± SD). When compared with presurgery, the VAS and all functional scores improved significantly at the last follow-up (P < .001 for all). Intra- and interobserver intraclass correlation coefficients indicated good reliability for the ADH measurements. Preoperatively, there were no differences in AHD values between the intact and affected shoulders (7.8 ± 0.8 mm for both; P = .851). The AHD values at postoperative day 1 and POM 6, POM 36, and POM 60 were 9.6 ± 0.7 mm, 8.6 ± 0.9 mm, 8.0 ± 0.8 mm, and 7.9 ± 0.8 mm, respectively, all of which were larger than those of the preoperative intact side (P < .001 for all). CONCLUSION: The modified suture button Latarjet procedure not only offered satisfactory therapeutic effects but also did not decrease the AHD at 5-year follow-up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...