Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chin Med J (Engl) ; 117(5): 700-5, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15161537

RESUMO

BACKGROUND: Previous studies have compared single-photon emission computed tomography (SPECT) and electron beam computed tomography (EBCT) in detection of coronary artery disease (CAD) in patients with myocardial infarction (MI). The purpose of this study was to compare SPECT with EBCT in detection of CAD in patients with no MI. METHODS: One hundred and forty-seven patients with suspected CAD underwent stress-rest (99)mTc-methoxyisobutylisonitrile ((99)mTc-MIBI) myocardial SPECT, cardiac EBCT and coronary angiography (CAG) within one month. Of them, 73 patients (aged 52.6 +/- 10.6 years old) with no history of MI were included in this study. Coronary artery calcium (CAC) was defined as a CT value >or= 130 HU within the boundary of coronary artery on EBCT. RESULTS: There were 35 and 38 patients with or without CAD according to CAG. Ninety-six percent of the patients with abnormal SPECT and CAC had a coronary arteries stenosis >or= 50%, and 90.9% patients with normal SPECT and EBCT showed no CAD. The sensitivity of SPECT and EBCT in detection of CAD was comparable, and the specificity of SPECT (92.1%) was significantly higher than that of EBCT (55.3%) (P < 0.005). For the detection of individual coronary artery stenosis, both sensitivity and specificity of SPECT (75.0% and 93.7%) were significantly higher than those of EBCT (53.3% and 76.7%) (P < 0.025 and P < 0.005, respectively). In patients without chest pain, the sensitivity and specificity of SPECT (76.9% and 91.4%) were significantly higher than those of EBCT (23.1% and 69.0%) in detection of a coronary artery stenosis of >or= 50% (P < 0.01 and P < 0.005, respectively). However, in patients with chest pain, both sensitivity and specificity of SPECT were comparable to those of EBCT. In patients or= 50% (P < 0.005), and the specificity of SPECT was comparable to that of EBCT. In patients > 45 years old, the specificity of SPECT (94.3%) was significantly higher than that of EBCT (70.5%) (P < 0.005), and the sensitivity of SPECT was comparable to that of EBCT. CONCLUSION: (99)mTc-MIBI myocardial perfusion SPECT has higher accuracy than that of EBCT in detection of CAD in patients without MI.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Adulto , Fatores Etários , Idoso , Cálcio/sangue , Dor no Peito/diagnóstico por imagem , Vasos Coronários/química , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...