1.
Water Sci Technol ; 48(4): 209-12, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14531443

RESUMO

The "BIO-Sulfex" biofilter of ATZ-EVUS removes hydrogen sulfide from biogas in a biological way. Hydrogen sulfide causes massive problems during power generation from biogas in a power plant, e.g. corrosion of engines and heat exchangers, and thus causes frequent and therefore expensive engine oil changes. The BIO-Sulfex module is placed between the digester and the power-plant and warrants a cost-effective, reliable and fully biological desulfurization. In the cleaned gas concentrations of less than 100 ppm can be achieved. Power-plant manufacturers usually demand less than 500 or less than 200 ppm. At present, several plants with biogas flow rates between 20 and 350 m3/h are in operation.


Assuntos
Poluição do Ar/prevenção & controle , Sulfeto de Hidrogênio/isolamento & purificação , Sulfeto de Hidrogênio/metabolismo , Bactérias Anaeróbias , Biodegradação Ambiental , Reatores Biológicos , Desenho de Equipamento , Filtração