1.
Med Devices (Auckl) ; 9: 389-393, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27843360

RESUMO

The periauricular percutaneous implantation of the Neuro-Stim System™ family of devices EAD, MFS, and BRIDGE is a procedure involving the use of a non-opiate, neuromodulation analgesic for relieving acute and chronic pain. It has been approved as a minimal-risk procedure by multiple governmental and institutional facilities. This retrospective report of findings will help quantify the incidence of clinically observed bleeding, localized dermatitis, and infections at the implantation sites of the electrode/needle arrays, dermatitis at the site of the generator, and patient syncope. A total of 1,207 devices, each producing up to 16 percutaneous punctures, for a total of 19,312 punctures were monitored for adverse effects, based on retrospective chart audits conducted at six clinical facilities over a 1-year period.

3.
Am J Transplant ; 5(6): 1518-28, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15888063

RESUMO

Reports on the accuracy of magnetic resonance angiography (MRA) and magnetic resonance venography (MRV) in evaluating living donor renovasculature employ few patients or omit the consequences of inaccurate scans. We retrospectively compared intraoperative findings to MRA/MRV scans in 146 donor-recipient pairs. For detecting accessory arteries and early branching, MRA sensitivity was 57.6%, specificity 96.5%, false positive rate 3.5%, false negative rate 42.4%, positive predictive value 82.6%, negative predictive value 88.6% and overall accuracy 87.7%. By excluding clinically inconsequential accessory arteries, MRA sensitivity rose to 73.1%, specificity to 96.7% and overall accuracy to 92.5%. For MRVs, sensitivity was 56.2%, specificity 99%, false positive rate 1%, false negative rate 43.8%, positive predictive value 90%, negative predictive value 94.8% and accuracy 94.5%. Inaccurate scans were associated with prolonged donor and recipient operations and more frequently reconstructed arteries, but did not affect clinical outcomes. Because most missed accessory arteries are inconsequential, MRA is a useful, less invasive method for defining donor renovascular anatomy.


Assuntos
Transplante de Rim/fisiologia , Rim/irrigação sanguínea , Angiografia por Ressonância Magnética , Circulação Renal , Doadores de Tecidos , Adulto , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Liver Transpl ; 11(2): 236-8, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15666373

RESUMO

A 53-year-old male with hepatitis C cirrhosis, who had been refused liver transplantation because of hypertrophic cardiomyopathy (HC), underwent nonsurgical septal ablation using alcohol with resolution of his ventricular outflow obstruction. This patient was able to subsequently undergo a successful deceased donor liver transplantation. This is the first reported case of alcohol induced septal ablation being performed in a cirrhotic patient with HC. Such nonsurgical procedures may be attractive in cirrhotic patients who are refused access to liver transplantation because of high surgical risk.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter , Transplante de Fígado , Cardiomiopatia Hipertrófica/epidemiologia , Contraindicações , Hepatite C/epidemiologia , Humanos , Cirrose Hepática/epidemiologia , Masculino , Pessoa de Meia-Idade , Obstrução do Fluxo Ventricular Externo/cirurgia
SELEÇÃO DE REFERÊNCIAS