Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Radiother Oncol ; 190: 110009, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37972735

RESUMO

BACKGROUND AND PURPOSE: Since 2011, our center has been using a library-based Plan-of-the-Day (PotD) strategy for external beam radiotherapy of cervical cancer patients to reduce normal tissue dose while maintaining adequate target coverage. With the advent of fully online-adaptive techniques such as daily online-adaptive replanning, further dose reduction may be possible. However, it is unknown how this reduction relates to plan library approaches, and how the most recent PotD strategies relate to no adaptation. In this study we compare the performance of our current PotD strategy with non-adaptive and fully online-adaptive techniques in terms of target volume size and normal tissue sparing. MATERIALS AND METHODS: Treatment data of 376 patients treated with the PotD protocol between June 2011 and April 2020 were included. The size of the Planning Target Volumes (PTVs) was reconstructed for different strategies: full online adaptation, no adaptation, and the latest clinical version of the PotD protocol. Normal tissue sparing was estimated by the difference in margin volume to construct the PTV and the volume overlap of the PTV with bladder and rectum. RESULTS: The current version of our PotD approach reduced the PTV margin volume by a median of 250 cm3 compared to no adaptation. Bladder-PTV overlap decreased from a median of 142 to 71 cm3, and from 39 to 16 cm3 for rectum-PTV. Fully online-adaptive approaches could further decrease the PTV volume by 144 cm3 using a 5 mm margin for residual errors. In this scenario, bladder-PTV overlap was reduced to 35 cm3 and rectum-PTV overlap to 11 cm3. CONCLUSION: The current version of the PotD protocol is an effective technique to improve normal tissue sparing compared to no adaptation. Further sparing can be achieved using fully online-adaptive techniques, but at the cost of a more complex workflow and with a potentially limited impact. PotD-type protocols can therefore be considered as a suitable alternative to fully online-adaptive approaches.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Órgãos em Risco , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Bexiga Urinária , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
3.
J Palliat Med ; 25(10): 1533-1539, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35482284

RESUMO

Purpose: The aim of this prospective cohort study was to determine the outcome and quality of life (QoL) for patients with brain metastases treated with whole-brain radiotherapy (WBRT). Materials and Methods: WBRT was given to 162 patients. Treatment outcome was reported through telephone consultation at four and eight weeks after the last fraction of the treatment. Treatment outcome was scored as a benefit when patients reported positively on the question whether radiotherapy of the whole brain did relieve their complaints. Patients who scored the treatment as beneficial were categorized as responders. The European Organization for Research and Treatment of Cancer (EORTC) questionnaire QLQ-C15-PAL was scored at day 0 and eight weeks after the last fraction of WBRT. Results: Patients who were alive after 2 months and reported benefit from treatment had a median survival of 8.1 months compared with 2.9 months for patients who reported no benefit. Forty-three patients died within two months (27%). Median overall survival was 3.5 months. Improvement of neurological symptoms was the most commonly reported benefit of the treatment. The responders had significantly better sleep (p = 0.032) and were less tense (p = 0.014). The nonresponders were also less tense (p = 0.042), but had less appetite (p = 0.023), felt weaker (p = 0.011), and experienced more fatigue (p = 0.001). Conclusions: WBRT is effective in a selected group of patients. Forty-nine percent of the patients surviving two months reported benefit from the treatment, resulting in a significantly increased survival rate for this group. However, 27% of patients died within two months. QoL increased in responders, but decreased in nonresponders.


Assuntos
Neoplasias Encefálicas , Qualidade de Vida , Encéfalo , Neoplasias Encefálicas/radioterapia , Humanos , Medidas de Resultados Relatados pelo Paciente , Estudos Prospectivos , Encaminhamento e Consulta , Telefone
4.
Artigo em Inglês | MEDLINE | ID: mdl-35243045

RESUMO

INTRODUCTION: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). MATERIALS AND METHODS: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breath-holds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. RESULTS: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. CONCLUSION: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.

5.
Int J Radiat Oncol Biol Phys ; 93(3): 532-9, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26460995

RESUMO

PURPOSE: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. METHODS AND MATERIALS: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss. In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. RESULTS: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and -3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and -1.3/4.5/3.6 mm. CONCLUSIONS: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.


Assuntos
Artefatos , Colo do Útero/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Pontos de Referência Anatômicos/diagnóstico por imagem , Fracionamento da Dose de Radiação , Desenho de Equipamento , Feminino , Ouro , Humanos , Posicionamento do Paciente , Polímeros , Decúbito Ventral , Implantação de Prótese/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada , Estudos Retrospectivos , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia
6.
Radiother Oncol ; 117(3): 536-41, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26409830

RESUMO

BACKGROUND AND PURPOSE: With the introduction of Intensity Modulated Radiotherapy (IMRT) and image-guided plan-of-the-day strategies, the treatment of cervical cancer has become more sensitive to intra-fraction uncertainties. In this study we quantified intra-fraction changes in cervix-uterus shape, bladder and rectum filling, and patient setup using pre- and post-fraction CBCT scans. MATERIALS AND METHODS: A total of 632 CBCT scans were analyzed for 16 patients with large tip-of-uterus displacement (>2.5 cm) measured in an empty and full bladder CT scan. In all scans, the bladder, cervix-uterus, and rectum were delineated. For rectum and bladder, intra-fraction volume changes were assessed. Systematic cervix-uterus intra-fraction displacements were obtained by non-rigidly aligning the pre-fraction cervix-uterus to that in the post-fraction CBCT. Intra-fraction patient setup changes were obtained by rigidly aligning pre- and post-CBCTs using the bony anatomy. RESULTS: The mean time between pre- and post-fraction CBCT scan was 20.8 min. The group-mean intra-fraction displacements averaged over the cervix-uterus were 0.1±1.4/1.8±1.5/-2.8±1.8 (LR/CC/AP) mm. The group-mean 5th and 95th percentile intra-fraction displacements were -2.3,2.1/-0.8,4.9/-5.8,0.5 (LR/CC/AP) mm. There was a significant correlation between bladder inflow rate and cervix-uterus motion (r=0.6 and p<0.01). Intra-fraction changes in patient setup were 1.3/0.4/0.6 and 1.4/1.0/1.1 mm (LR/CC/AP), for systematic and random changes, respectively. CONCLUSION: Intra-fraction cervix-uterus motion can be considerable and should be taken into account using appropriate PTV margins.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem
7.
Med Image Comput Comput Assist Interv ; 17(Pt 1): 528-35, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25333159

RESUMO

We propose a method to automatically select a treatment plan for radiotherapy of cervical cancer using a Plan-of-the-Day procedure, in which multiple treatment plans are constructed prior to treatment. The method comprises a multi-atlas based segmentation algorithm that uses the selected treatment plan to choose between two atlas sets. This segmentation only requires two registration procedures and can therefore be used in clinical practice without using excessive computation time. Our method is validated on a dataset of 224 treatment fractions for 10 patients. In 37 cases (16%), no recommendation was made by the algorithm due to poor image quality or registration results. In 93% of the remaining cases a correct recommendation for a treatment plan was given.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Inteligência Artificial , Feminino , Humanos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Int J Radiat Oncol Biol Phys ; 90(3): 673-9, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25151538

RESUMO

PURPOSE: To evaluate the clinical implementation of an online adaptive plan-of-the-day protocol for nonrigid target motion management in locally advanced cervical cancer intensity modulated radiation therapy (IMRT). METHODS AND MATERIALS: Each of the 64 patients had four markers implanted in the vaginal fornix to verify the position of the cervix during treatment. Full and empty bladder computed tomography (CT) scans were acquired prior to treatment to build a bladder volume-dependent cervix-uterus motion model for establishment of the plan library. In the first phase of clinical implementation, the library consisted of one IMRT plan based on a single model-predicted internal target volume (mpITV), covering the target for the whole pretreatment observed bladder volume range, and a 3D conformal radiation therapy (3DCRT) motion-robust backup plan based on the same mpITV. The planning target volume (PTV) combined the ITV and nodal clinical target volume (CTV), expanded with a 1-cm margin. In the second phase, for patients showing >2.5-cm bladder-induced cervix-uterus motion during planning, two IMRT plans were constructed, based on mpITVs for empty-to-half-full and half-full-to-full bladder. In both phases, a daily cone beam CT (CBCT) scan was acquired to first position the patient based on bony anatomy and nodal targets and then select the appropriate plan. Daily post-treatment CBCT was used to verify plan selection. RESULTS: Twenty-four and 40 patients were included in the first and second phase, respectively. In the second phase, 11 patients had two IMRT plans. Overall, an IMRT plan was used in 82.4% of fractions. The main reasons for selecting the motion-robust backup plan were uterus outside the PTV (27.5%) and markers outside their margin (21.3%). In patients with two IMRT plans, the half-full-to-full bladder plan was selected on average in 45% of the first 12 fractions, which was reduced to 35% in the last treatment fractions. CONCLUSIONS: The implemented online adaptive plan-of-the-day protocol for locally advanced cervical cancer enables (almost) daily tissue-sparing IMRT.


Assuntos
Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Colo do Útero/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Feminino , Marcadores Fiduciais , Humanos , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/diagnóstico por imagem , Posicionamento do Paciente , Decúbito Ventral , Sistemas de Informação em Radiologia , Radioterapia Conformacional/métodos , Radioterapia Conformacional/estatística & dados numéricos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Fatores de Tempo , Neoplasias do Colo do Útero/patologia , Útero
9.
Int J Radiat Oncol Biol Phys ; 87(2): 401-6, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23958149

RESUMO

PURPOSE: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. METHODS AND MATERIALS: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. RESULTS: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4 mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r(2)=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r(2)=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. CONCLUSIONS: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Laríngeas/diagnóstico por imagem , Movimento , Posicionamento do Paciente , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia Guiada por Imagem/métodos , Vértebras Cervicais , Fracionamento da Dose de Radiação , Humanos , Neoplasias Laríngeas/radioterapia , Erros de Configuração em Radioterapia/estatística & dados numéricos , Radioterapia de Intensidade Modulada/métodos
10.
Acta Oncol ; 52(7): 1430-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23902275

RESUMO

PURPOSE: To dosimetrically evaluate a margin-of-the-day (MoD) online adaptive intensity-modulated radiotherapy (IMRT) strategy for cervical cancer patients. The strategy is based on a single planning computed tomography (CT) scan and a pretreatment constructed IMRT plan library with incremental clinical target volumes (CTV)-to-planning target volumes (PTV) margins. MATERIAL AND METHODS: For 14 patients, 9-10 variable bladder filling CT scans acquired at pretreatment and after 40 Gy were available. Bladder volume variability during the treatment course was recorded by twice-weekly US bladder-volume measurements. A MoD strategy that selects the best IMRT plan of the day from a library of plans with incremental margins in steps of 5 mm was compared with a clinically recommended population-based margin (15 mm). To compare the strategies, for each fraction that had a recorded US bladder-volume measurement, the CT scan with the nearest bladder volume was selected from the pretreatment CT series and from the CT series acquired after 40 Gy. A frequency-weighted average of the dose-volume histograms (DVH) parameters calculated for the two selected CT scans was used to estimate the DVH parameters of the fraction of interest. RESULTS: The 15-mm recommended margin resulted in cervix-uterus underdosage in six of 14 patients. Compared with the 15-mm margin, the MoD strategy resulted in significantly better cervix-uterus coverage (p = 0.008) without a significant difference in the sparing of rectum, bladder, and small bowel. For each patient, 3-8 (median 5) plans were needed in the library of plans for the MoD strategy. The required range of the MoD was 5-45 mm (median 15 mm). Twenty-five percent of all fractions could be treated with a MoD of 5 mm and 81% of all fractions could be treated with a MoD up to 25 mm. CONCLUSIONS: Compared with a clinically recommended margin, a simple online adaptive strategy resulted in better cervix-uterus coverage without compromising organs at risk sparing.


Assuntos
Radiometria , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Estadiamento de Neoplasias , Sistemas On-Line , Órgãos em Risco/efeitos da radiação , Prognóstico , Radioterapia de Intensidade Modulada , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem
11.
Radiother Oncol ; 103(3): 322-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22633814

RESUMO

PURPOSE: To quantify the impact of uncorrected or partially corrected pelvis rotation and spine bending on region-specific residual setup errors in prone-treated cervical cancer patients. METHODS AND MATERIALS: Fifteen patients received an in-room CBCT scan twice a week. CBCT scans were registered to the planning CT-scan using a pelvic clip box and considering both translations and rotations. For daily correction of the detected translational pelvis setup errors by couch shifts, residual setup errors were determined for L5, L4 and seven other points of interest (POIs). The same was done for a procedure with translational corrections and limited rotational correction (±3°) by a 6D positioning device. RESULTS: With translational correction only, residual setup errors were large especially for L5/L4 in AP direction (Σ=5.1/5.5mm). For the 7 POIs the residual setup errors ranged from 1.8 to 5.6mm (AP). Using the 6D positioning device, the errors were substantially smaller (for L5/L4 in AP direction Σ=2.7/2.2mm). Using this device, the percentage of fractions with a residual AP displacement for L4>5mm reduced from 47% to 9%. CONCLUSIONS: Setup variations caused by pelvis rotations are large and cannot be ignored in prone treatment of cervical cancer patients. Corrections with a 6D positioning device may considerably reduce resulting setup errors, but the residual setup errors should still be accounted for by appropriate CTV-to-PTV margins.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Erros de Configuração em Radioterapia , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Movimento , Decúbito Ventral , Planejamento da Radioterapia Assistida por Computador , Neoplasias do Colo do Útero/diagnóstico por imagem
12.
Int J Radiat Oncol Biol Phys ; 82(2): 1031-7, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21420248

RESUMO

PURPOSE: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. METHODS AND MATERIALS: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocol or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. RESULTS: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 ± 1.2 mm (mean ± 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. CONCLUSIONS: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.


Assuntos
Neoplasias da Mama/radioterapia , Protocolos Clínicos , Marcadores Fiduciais , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Instrumentos Cirúrgicos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Fracionamento da Dose de Radiação , Feminino , Humanos , Mamoplastia/métodos , Mastectomia Segmentar , Movimento (Física) , Posicionamento do Paciente , Estudos Prospectivos , Radiografia , Fatores de Tempo
13.
Radiother Oncol ; 99(2): 240-5, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21549441

RESUMO

BACKGROUND AND PURPOSE: To design and evaluate a 3D patient-specific model to predict the cervix-uterus shape and position. METHODS AND MATERIALS: For 13 patients lying in prone position, 10 variable bladder filling CT-scans were acquired, 5 at planning and 5 after 40Gy. The delineated cervix-uterus volumes in 2-5 pre-treatment CT-scans were used to generate patient-specific models that predict the cervix-uterus geometry by bladder volume. Model predictions were compared to delineations, excluding those used for model construction. The prediction error was quantified by the margin required around the predicted volumes to accommodate 95% of the delineated volume and by the predicted-to-delineated surface distance. RESULTS: The prediction margin was significantly smaller (average 50%) than the margin encompassing the cervix-uterus motion. The prediction margin could be decreased (from 7 to 5mm at planning and from 10 to 8mm after 40Gy) by increasing (from 2 to 5) the number of CT-scans used for the model construction. CONCLUSION: For most patients, even with a model based on only two CT-scans, the prediction error was well below the margin encompassing the cervix-uterus motion. The described approach could be used to create prior to treatment, an individualized treatment strategy.


Assuntos
Colo do Útero/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Artefatos , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Movimento , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Decúbito Ventral
14.
Radiother Oncol ; 98(3): 340-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21295877

RESUMO

PURPOSE: To investigate application of pre-treatment established correlations between bladder-filling changes and cervix-uterus displacements in adaptive therapy. MATERIALS AND METHODS: Thirteen cervical cancer patients participated in this prospective study. Pre-treatment, and after delivery of 40 Gy, a full bladder CT-scan was acquired, followed by voiding the bladder and acquisition of 4 other 3D scans in a 1h period with a naturally filling bladder (variable bladder filling CT-scans, VBF-scans). For the pre-treatment VBF-scans, linear correlations between bladder volume change and displacements of the tip of the uterus (ToU) and the center of mass (CoM) of markers implanted in the fornices of the vagina relative to the full bladder planning scan were established. Prediction accuracy of these correlation models was assessed by comparison with actual displacements in CT-scans, both pre-treatment and after 40 Gy. Inter-fraction ToU and marker-CoM displacements were derived from the established correlations and twice-weekly performed in-room bladder volume measurements, using a 3D ultrasound scanner. RESULTS: Target displacement in VBF-scans ranged from up to 65 mm in a single direction to almost 0mm, depending on the patient. For pre-treatment VBF-scans, the linear correlation models predicted the mean 3D position change for the ToU of 26.1 mm±10.8 with a residual of only 2.2 mm±1.7. For the marker-CoM, the 8.4 mm±5.3 mean positioning error was predicted with a residual of 0.9 mm±0.7. After 40Gy, the mean ToU displacement was 26.8 mm±15.8, while prediction based on the pre-treatment correlation models yielded a mean residual error of 9.0 mm±3.7. Target positioning errors in the fractioned treatments were very large, especially for the ToU (-18.5mm±11.2 for systematic errors in SI-direction). CONCLUSIONS: Pre-treatment acquired VBF-scans may be used to substantially enhance treatment precision of cervical cancer patients. Application in adaptive therapy is promising and warrants further investigation. For highly conformal (IMRT) treatments, the use of a full bladder drinking protocol results in unacceptably large systematic set-up errors.


Assuntos
Colo do Útero/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Relação Dose-Resposta à Radiação , Feminino , Humanos , Pessoa de Meia-Idade , Tamanho do Órgão , Radiografia , Dosagem Radioterapêutica , Neoplasias do Colo do Útero/diagnóstico por imagem
15.
Radiother Oncol ; 90(1): 110-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19010561

RESUMO

BACKGROUND AND PURPOSE: The aim of this study is to investigate whether surgical clips in the lumpectomy cavity are representative for position verification of both the tumour bed and the whole breast in simultaneously integrated boost (SIB) treatments. MATERIALS AND METHODS: For a group of 30 patients treated with a SIB technique, kV and MV planar images were acquired throughout the course of the fractionated treatment. The 3D set-up error for the tumour bed was derived by matching the surgical clips (3-8 per patient) in two almost orthogonal planar kV images. By projecting the 3D set-up error derived from the planar kV images to the (u, v)-plane of the tangential beams, the correlation with the 2D set-up error for the whole breast, derived from the MV EPID images, was determined. The stability of relative clip positions during the fractionated treatment was investigated. In addition, for a subgroup of 15 patients, the impact of breathing was determined from fluoroscopic movies acquired at the linac. RESULTS: The clip configurations were stable over the course of radiotherapy, showing an inter-fraction variation (1 SD) of 0.5mm on average. Between the start and the end of the treatment, the mean distance between the clips and their center of mass was reduced by 0.9 mm. A decrease larger than 2mm was observed in eight patients (17 clips). The top-top excursion of the clips due to breathing was generally less than 2.5mm in all directions. The population averages of the difference (+/-1 SD) between kV and MV matches in the (u, v)-plane were 0.2+/-1.8mm and 0.9+/-1.5mm, respectively. In 30% of the patients, time trends larger than 3mm were present over the course of the treatment in either or in both kV and MV match results. Application of the NAL protocol based on the clips reduced the population mean systematic error to less than 2mm in all directions, both for the tumour bed and the whole breast. Due to the observed time trends, these systematic errors can be further reduced to about 1mm by using an eNAL protocol instead. CONCLUSIONS: The relative positions of implanted surgical clips in the lumpectomy cavity after breast-conserving surgery remain stable during the course of radiotherapy treatment. Application of a NAL or eNAL set-up correction protocol based on surgical clips allows for adequate treatment of both the tumour bed and the whole breast with tight CTV-PTV margins.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Instrumentos Cirúrgicos , Tomografia Computadorizada por Raios X , Neoplasias da Mama/cirurgia , Terapia Combinada , Fracionamento da Dose de Radiação , Feminino , Humanos , Modelos Lineares , Mastectomia Segmentar , Movimento (Física) , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista , Resultado do Tratamento
16.
Radiother Oncol ; 89(2): 172-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18703248

RESUMO

BACKGROUND AND PURPOSE: For cervical cancer patients, bladder filling variations may result in inadequate EBRT target coverage, unless large safety margins are used. For a group of patients who received full bladder instructions, inter-fraction variations and time trends in bladder volume were quantified, and a 3D ultrasound (US) scanner was tested for on-line bladder volume measurements. METHODS AND MATERIALS: For 24 patients, the bladder volume was measured with US at the time of the planning CT scan, and twice weekly during the course of RT. Comparisons of US with planning CT were used to assess the bladder scanner accuracy. Patients were treated in prone on a belly board, EPID images were acquired to correlate set-up errors with bladder filling variations. RESULTS: Measured US and CT bladder volumes were strongly correlated (R = 0.97, slope 1.1 +/- 0.1). The population mean bladder volume at planning of 378 +/- 209 ml (1 SD) reduced to 109 +/- 88 ml (1 SD) in week 6, a reduction by 71% (average reduction 46 ml/week), revealing a large inter-fraction time trend. Intra-patient variation in bladder volume during RT was 168 ml (1 SD) (range 70-266 ml). Rotation around the LR axis was significantly correlated with bladder volume changes. CONCLUSIONS: Despite a full bladder instruction, bladder volumes reduced dramatically during treatment, implying large time trends in target position of these patients. The portable US scanner provides a quick and reliable measurement of the bladder volume, which might assist future online treatment adaptation.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Ultrassonografia/instrumentação , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Fracionamento da Dose de Radiação , Feminino , Humanos , Tamanho do Órgão , Fatores de Tempo , Tomografia Computadorizada por Raios X , Bexiga Urinária/anatomia & histologia , Neoplasias do Colo do Útero/diagnóstico por imagem
17.
Int J Radiat Oncol Biol Phys ; 54(2): 576-83, 2002 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-12243838

RESUMO

PURPOSE: To investigate the use of a fluoroscopic electronic portal imaging device (EPID) and radiopaque markers to detect internal cervix movement. METHODS AND MATERIALS: For 10 patients with radiopaque markers clamped to the cervix, electronic portal images were made during external beam irradiation. Bony structures and markers in the portal images were registered with the same structures in the corresponding digitally reconstructed radiographs of the planning computed tomogram. RESULTS: The visibility of the markers in the portal images was good, but their fixation should be improved. Generally, the correlation between bony structure displacements and marker movement was poor, the latter being substantially larger. The standard deviations describing the systematic and random bony anatomy displacements were 1.2 and 2.6 mm, 1.7 and 2.9 mm, and 1.6 and 2.7 mm in the lateral, cranial-caudal, and dorsal-ventral directions, respectively. For the marker movement those values were 3.4 and 3.4 mm, 4.3 and 5.2 mm, 3.2 and 5.2 mm, respectively. Estimated clinical target volume to planning target volume (CTV-PTV) planning margins (approximately 11 mm) based on the observed overall marker displacements (bony anatomy + internal cervix movement) are only marginally larger than the margins required to account for internal marker movement alone. CONCLUSIONS: With our current patient setup techniques and methods of setup verification and correction, the required CTV-PTV margins are almost fully determined by internal organ motion. Setup verification and correction using radiopaque markers might allow decreasing those margins, but technical improvements are needed.


Assuntos
Colo do Útero/diagnóstico por imagem , Fluoroscopia/instrumentação , Movimento , Imagens de Fantasmas , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Ossos Pélvicos/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...