Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 78(5): 2022-2034, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28261847

RESUMO

PURPOSE: To develop a method for improved B0 field-map estimation, deblurring, and image combination for multispectral imaging near metal. METHODS: A goodness-of-fit field-map estimation technique is proposed that uses only the multispectral imaging (MSI) data to estimate the field map. Using the improved field map, a novel deblurring technique is proposed that also employs a new image combination scheme to reduce the effects of noise and other residual MSI artifacts. The proposed field-map estimation and deblurring techniques are compared to the current methods in phantoms and/or in vivo from subjects with knee, hip, and spinal metallic implants. RESULTS: Phantom experiments validate that the goodness-of-fit field-map estimation is less sensitive to noise and bias than the conventional center-of-mass technique, which reduces distortion in the deblurring methods. The new deblurring approach also is substantially less sensitive to noise and distortion than the current deblurring method, as demonstrated in phantoms and in vivo, and is able to find a good tradeoff between deblurring and distortion. CONCLUSION: The proposed methods not only enable field-mapping with reduced noise sensitivity but are able to create deblurred images with less distortion and better signal-to-noise ratio with no additional scan time, thereby enabling improved visualization of underlying anatomy near metallic implants. Magn Reson Med 78:2022-2034, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Metais/química , Algoritmos , Humanos , Prótese Articular , Imagens de Fantasmas
2.
Magn Reson Med ; 74(3): 706-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25227766

RESUMO

PURPOSE: To develop a three-dimensional (3D) balanced steady-state free-precession (bSSFP) two-point Dixon method with banding-artifact suppression to offer robust high-resolution 3D bright-fluid imaging. METHODS: A complex sum reconstruction that combines phase-cycled bSSFP images acquired at specific echo times for robust fat/water separation without banding was investigated and compared with a magnitude-based method. Bloch simulations using both single-peak and multiple-peak fat models were performed to predict the performance of these methods for a wide range of echo times and repetition times. The quality and degree of fat/water separation was evaluated in both simulations and using in vivo imaging. RESULTS: Simulations predicted that both effective banding-artifact suppression and substantial improvements in fat/water separation are possible at echo times that are different from conventional echo times, enabling improved spatial resolution. Comparisons between various echo times and repetition times in vivo validated the improved fat/water separation and effective banding-artifact removal predicted by the simulations. CONCLUSION: The proposed complex sum Dixon 3D bSSFP method is able to effectively separate fat and water at different sets of echo times, while removing banding-artifacts, providing a fast, high-resolution, T2 -like sequence without blurring.


Assuntos
Artefatos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Tecido Adiposo/fisiologia , Água Corporal/fisiologia , Simulação por Computador , Humanos
3.
Magn Reson Med ; 67(4): 1004-12, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22038883

RESUMO

Balanced steady-state free precession (bSSFP) MRI is a rapid and signal-to-noise ratio-efficient imaging method, but suffers from characteristic bands of signal loss in regions of large field inhomogeneity. Several methods have been developed to reduce the severity of these banding artifacts, typically involving the acquisition of multiple bSSFP datasets (and the accompanying increase in scan time). Fat suppression with bSSFP is also challenging; most existing methods require an additional increase in scan time, and some are incompatible with bSSFP band-reduction techniques. This work was motivated by the need for both robust fat suppression and band reduction in the presence of field inhomogeneity when using bSSFP for flow-independent peripheral angiography. The large flip angles used in this application to improve vessel conspicuity and contrast lead to specific absorption rate considerations, longer repetition times, and increased severity of banding artifacts. In this work, a novel method that simultaneously suppresses fat and reduces bSSFP banding artifact with the acquisition of only two phase-cycled bSSFP datasets is presented. A weighted sum of the two bSSFP acquisitions is taken on a voxel-by-voxel basis, effectively synthesizing an off-resonance profile at each voxel that puts fat in the stop band while keeping water in the pass band. The technique exploits the near-sinusoidal shape of the bSSFP off-resonance spectrum for many tissues at large (>50°) flip angles.


Assuntos
Perna (Membro)/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/anatomia & histologia , Algoritmos , Artefatos , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...