Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(4)2021 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33670276

RESUMO

At the micrometric scale, vessels or skin capillaries network architecture can provide useful information for human health management. In this paper, from simulation to in vitro, we investigate some limits and interests of optical feedback interferometry (OFI) for blood flow imaging of skin vascularization. In order to analyze the tissue scattering effect on OFI performances, a series of skin-tissue simulating optical phantoms have been designed, fabricated and characterized. The horizontal (2D) and vertical (depth penetration) sensing resolution of the OFI sensor have been estimated. The experimental results that we present on this study are showing a very good accordance with theoretical models. In the case of a skin phantom of 0.5 mm depth with a scattering coefficient from 0 to 10.8 mm-1, the presented OFI system is able to distinguish a pair of micro fluidic channels (100 µm × 100 µm) spaced by 10 µm. Eventually, an in vivo test on human skin is presented and, for the first time using an OFI sensor, a 2D blood flow image of a vein located just beneath the skin is computed.


Assuntos
Interferometria , Dispositivos Ópticos , Pele/irrigação sanguínea , Simulação por Computador , Retroalimentação , Humanos , Imagens de Fantasmas
2.
Sensors (Basel) ; 18(7)2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29966339

RESUMO

Enhanced understanding and control of electrophysiology mechanisms are increasingly being hailed as key knowledge in the fields of modern biology and medicine. As more and more excitable cell mechanics are being investigated and exploited, the need for flexible electrophysiology setups becomes apparent. With that aim, we designed Multimed, which is a versatile hardware platform for the real-time recording and processing of biosignals. Digital processing in Multimed is an arrangement of generic processing units from a custom library. These can freely be rearranged to match the needs of the application. Embedded onto a Field Programmable Gate Array (FPGA), these modules utilize full-hardware signal processing to lower processing latency. It achieves constant latency, and sub-millisecond processing and decision-making on 64 channels. The FPGA core processing unit makes Multimed suitable as either a reconfigurable electrophysiology system or a prototyping platform for VLSI implantable medical devices. It is specifically designed for open- and closed-loop experiments and provides consistent feedback rules, well within biological microseconds timeframes. This paper presents the specifications and architecture of the Multimed system, then details the biosignal processing algorithms and their digital implementation. Finally, three applications utilizing Multimed in neuroscience and diabetes research are described. They demonstrate the system’s configurability, its multi-channel, real-time processing, and its feedback control capabilities.


Assuntos
Pesquisa Biomédica/métodos , Fenômenos Eletrofisiológicos/fisiologia , Neurociências/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Diabetes Mellitus , Retroalimentação , Humanos , Fatores de Tempo
3.
Sensors (Basel) ; 16(5)2016 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-27187406

RESUMO

Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current biophotonics research and market trends. The present paper is a review of the work in progress at UPC-CD6 and LAAS-CNRS related to the application of OFI to different aspects of biosensing, both in vivo and ex vivo. This work is intended to present the variety of opportunities and potential applications related to OFI that are available in the field. The activities presented are divided into two main sensing strategies: The measurement of optical path changes and the monitoring of flows, which correspond to sensing strategies linked to the reconstruction of changes of amplitude from the interferometric signal, and to classical Doppler frequency measurements, respectively. For optical path change measurements, measurements of transient pulses, usual in biosensing, together with the measurement of large displacements applied to designing palliative care instrumentation for Parkinson disease are discussed. Regarding the Doppler-based approach, progress in flow-related signal processing and applications in real-time monitoring of non-steady flows, human blood flow monitoring and OFI pressure myograph sensing will be presented. In all cases, experimental setups are discussed and results presented, showing the versatility of the technique. The described applications show the wide capabilities in biosensing of the OFI sensor, showing it as an enabler of low-cost, all-optical, high accuracy biomedical applications.


Assuntos
Técnicas Biossensoriais , Dispositivos Ópticos , Retroalimentação Sensorial , Humanos , Interferometria , Processamento de Sinais Assistido por Computador
4.
Circulation ; 130(7): 530-8, 2014 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-25028391

RESUMO

BACKGROUND: Specific noninvasive signal processing was applied to identify drivers in distinct categories of persistent atrial fibrillation (AF). METHODS AND RESULTS: In 103 consecutive patients with persistent AF, accurate biatrial geometry relative to an array of 252 body surface electrodes was obtained from a noncontrast computed tomography scan. The reconstructed unipolar AF electrograms acquired at bedside from multiple windows (duration, 9±1 s) were signal processed to identify the drivers (focal or reentrant activity) and their cumulative density map. The driver domains were catheter ablated by using AF termination as the procedural end point in comparison with the stepwise-ablation control group. The maps showed incessantly changing beat-to-beat wave fronts and varying spatiotemporal behavior of driver activities. Reentries were not sustained (median, 2.6 rotations lasting 449±89 ms), meandered substantially but recurred repetitively in the same region. In total, 4720 drivers were identified in 103 patients: 3802 (80.5%) reentries and 918 (19.5%) focal breakthroughs; most of them colocalized. Of these, 69% reentries and 71% foci were in the left atrium. Driver ablation alone terminated 75% and 15% of persistent and long-lasting AF, respectively. The number of targeted driver regions increased with the duration of continuous AF: 2 in patients presenting in sinus rhythm, 3 in AF lasting 1 to 3 months, 4 in AF lasting 4 to 6 months, and 6 in AF lasting longer. The termination rate sharply declined after 6 months. The mean radiofrequency delivery to AF termination was 28±17 minutes versus 65±33 minutes in the control group (P<0.0001). At 12 months, 85% patients with AF termination were free from AF, similar to the control population (87%,); P=not significant. CONCLUSIONS: Persistent AF in early months is maintained predominantly by drivers clustered in a few regions, most of them being unstable reentries.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Idoso , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
5.
Artigo em Inglês | MEDLINE | ID: mdl-24109652

RESUMO

Glucose sensors have improved and facilitated therapy for type 1 diabetes. However, they are still not capable to sense all physiological signals and to act in a closed-loop. Pancreatic ß-cells have been shaped during evolution as biological sensors and offer the advantage to integrate all physiological signals in addition to glucose. Moreover, biosensors based on these cells may also serve for non-invasive and continuous long-term characterization of ß-cells, drug research, tissue engineering and pre-transplantation quality control. ß-cells alter their electrical activity upon exposure to glucose and physiological hormones and we have used these properties to design a biosensor. To this end signals were recorded extracellularly from islet cells kept on multi-electrode arrays. Slow and rapid oscillations were observed, both modulated by glucose. Especially slow oscillations are very robust and have an excellent signal/noise ratio. Signal processing functions were designed to separate the two activities to extract and analyze relevant parameters. These parameters correlate very well with either increasing or decreasing glucose concentrations. An electronic device is under construction, based on an embedded FPGA capable of processing multiple channels in parallel. In the future, such a device shall be used as a portable real-time biosensor regulating insulin delivery from a pump.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletrônica/instrumentação , Fenômenos Eletrofisiológicos , Glucose/análise , Células Secretoras de Insulina/fisiologia , Potenciais de Ação/fisiologia , Animais , Células Cultivadas , Eletrodos , Camundongos , Processamento de Sinais Assistido por Computador
6.
J Physiol ; 590(5): 1085-91, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22199167

RESUMO

Non-invasive high-throughput and long-term monitoring of endocrine cells is important for drug research, phenotyping, tissue engineering and pre-transplantation quality control. Here we report a novel approach to obtain simultaneous long-term electrical recordings of different islet cell types using multi-electrode arrays. We implemented wavelet transforms to resolve the low signal/noise ratio inherent to these measurements and extracted on-line a signature specific of cell activity. The architecture employed allows multiplexing a large number of electrodes for high-throughput screening. This method should be of considerable advantage in endocrine research and may be extended to other excitable cells previously not accessible to the technique.


Assuntos
Ilhotas Pancreáticas/fisiologia , Animais , Células Cultivadas , Camundongos , Microeletrodos , Técnicas de Patch-Clamp
7.
Front Neuroeng ; 4: 7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21811455

RESUMO

We present a study on wavelet detection methods of neuronal action potentials (APs). Our final goal is to implement the selected algorithms on custom integrated electronics for on-line processing of neural signals; therefore we take real-time computing as a hard specification and silicon area as a price to pay. Using simulated neural signals including APs, we characterize an efficient wavelet method for AP extraction by evaluating its detection rate and its implementation cost. We compare software implementation for three methods: adaptive threshold, discrete wavelet transform (DWT), and stationary wavelet transform (SWT). We evaluate detection rate and implementation cost for detection functions dynamically comparing a signal with an adaptive threshold proportional to its SD, where the signal is the raw neural signal, respectively: (i) non-processed; (ii) processed by a DWT; (iii) processed by a SWT. We also use different mother wavelets and test different data formats to set an optimal compromise between accuracy and silicon cost. Detection accuracy is evaluated together with false negative and false positive detections. Simulation results show that for on-line AP detection implemented on a configurable digital integrated circuit, APs underneath the noise level can be detected using SWT with a well-selected mother wavelet, combined to an adaptive threshold.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...