Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38419402

RESUMO

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Pulmonar , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Ásia , Catéteres
4.
Curr Cardiol Rep ; 24(5): 587-596, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35230616

RESUMO

PURPOSE OF REVIEW: Establishing the Fontan circulation has led to improved survival in patients born with complex congenital heart diseases. Despite early success, the long-term course of Fontan patients is complicated by multi-organ dysfunction, mainly due to a combination of low resting and blunted exercise-augmented cardiac output as well as elevated central venous (Fontan) pressure. Similarly, despite absolute hemodynamic differences compared to the normal population with biventricular circulation, the "normal" ranges of hemodynamic parameters specific to age-appropriate Fontan circulation have not been well defined. With the ever-increasing population of patients requiring Fontan correction, it is of utmost importance that an acceptable range of hemodynamics in this highly complex patient cohort is better defined. RECENT FINDINGS: Multiple publications have described hemodynamic limitations and potential management options in patients with Fontan circulation; however, an acceptable range of hemodynamic parameters in this patient population has not been well defined. Identification of "normal" hemodynamic parameters among patients with Fontan circulation will allow physicians to more objectively define indications for intervention, which is a necessary first step to eliminate institutional and regional heterogeneity in Fontan management and potentially improve long-term clinical outcomes.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Cardiopatias Congênitas/complicações , Hemodinâmica , Humanos
6.
JACC Case Rep ; 3(14): 1569-1575, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34729502

RESUMO

Central thrombosis-associated chylothorax is underrecognized in children and frequently refractory to conservative management. Central venous catheterizations are the predominate cause. We present 3 cases highlighting endovascular techniques used to treat persistent chylous effusions. (Level of Difficulty: Advanced.).

7.
Catheter Cardiovasc Interv ; 98(1): 128-136, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33909945

RESUMO

BACKGROUND: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS: An international registry reviewed the outcomes of 10-zig CCP stents in 75 patients aged 11.4-75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. RESULTS: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). CONCLUSIONS: Ten-zig CCPs of 7-8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.


Assuntos
Comunicação Interatrial , Platina , Humanos , Sistema de Registros , Stents , Resultado do Tratamento , Veia Cava Superior
8.
Cardiol Young ; 31(8): 1376-1379, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33766177

RESUMO

Transcatheter creation of an interatrial communication using the Occlutech Atrial Flow Regulator Device for pulmonary hypertension or heart failure is well described. We report a case of an 8-year-old boy with a failing Fontan circulation, in whom the Atrial Flow Regulator was used to successfully create a fenestration between the pulmonary artery and left atrium, improving his clinical condition.


Assuntos
Apêndice Atrial , Técnica de Fontan , Hipertensão Pulmonar , Cateterismo Cardíaco , Criança , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Hipertensão Pulmonar/etiologia , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia
9.
Ann Thorac Surg ; 112(4): e291-e294, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33535063

RESUMO

Percutaneous pulmonary valve replacement with the self-expandable Venus P-valve (Venus Medtech, Hangzhou, China) has shown satisfactory feasibility and early and midterm outcomes. However, the long-term results are not well described. This is a report of the gross and microscopic findings of an explanted Venus P-valve 78 months after implantation.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Adolescente , Remoção de Dispositivo , Feminino , Humanos , Desenho de Prótese , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/etiologia , Fatores de Tempo , Resultado do Tratamento
10.
Ann Thorac Surg ; 112(3): e165-e168, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33497660

RESUMO

The use of Melody valves in the mitral position has been introduced in clinical practice. Stent fracture is a recognized complication of Melody valve implantation in the pulmonary position; however, reports in the mitral position are rare. We present the case of an 8-year-old boy in whom complete fracture of the proximal stent struts occurred, causing acute severe mitral stenosis, and in whom urgent hybrid transapical Melody valve implantation in the fractured Melody valve was performed successfully using a novel modified technique. This modification simplified the implantation, led to reduced time of the procedure, and minimized hemodynamic instability.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/etiologia , Falha de Prótese/efeitos adversos , Criança , Humanos , Masculino
11.
Clin Med (Lond) ; 20(6): 593-596, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33199327

RESUMO

Exertional breathlessness and hypoxia are common presenting complaints in acute medicine. We describe a case where the patient continued to have persistent hypoxia even after the primary cause (pulmonary embolism) was diagnosed and treated. The hypoxia persisted as an enigma, its cause remaining elusive till diagnosed. Standard first-line investigations would not have reached the underlying diagnosis in this case and, as such, it demonstrates the keen clinical sense and complex investigative strategy required to solve the puzzle.


Assuntos
Forame Oval Patente , Embolia Pulmonar , Dispneia/etiologia , Humanos , Hipóxia/etiologia
12.
Curr Cardiol Rep ; 22(12): 158, 2020 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-33037461

RESUMO

PURPOSE OF REVIEW: Cardiac catheterization therapies to treat or palliate infants, children and adults with congenital heart disease have developed rapidly worldwide in both technical innovation and device development in the previous three decades. By reviewing of current status of novel or development of devices and techniques, we will discuss what is likely to happen in paediatric heart intervention in the next decade. RECENT FINDINGS: Recently, biodegradable stents and devices, transcatheter pulmonary valve implantation for the native right ventricle outflow tract and MRI-guided interventions have been progressing rapidly with good immediate to early results. These are expected to be introduced and spread in the next decade although there are still challenges to overcome. The future of paediatric heart intervention is very promising with rapid development of technological progress.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Cateterismo Cardíaco , Criança , Cardiopatias Congênitas/cirurgia , Humanos , Resultado do Tratamento
13.
Cardiol Young ; 30(5): 649-655, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32321616

RESUMO

AIMS: Management strategies for pulmonary atresia with intact ventricular septum are variable and are based on right ventricular morphology and associated abnormalities. Catheter perforation of the pulmonary valve provides an alternative strategy to surgery in the neonatal period. We sought to assess the long-term outcome in terms of survival, re-intervention, and functional ventricular outcome in the setting of a 26-year single-centre experience of low threshold inclusion criteria for percutaneous valvotomy. METHODS AND RESULTS: Retrospective analysis of patients diagnosed with pulmonary atresia with intact ventricular septum from 1990 to 2016 at a tertiary referral centre, was performed. Of 71 patients, 48 were brought to the catheterisation laboratory for intervention. Catheter valvotomy was successful in 45 patients (94%). Twenty-three patients (51%) also underwent ductus arteriosus stenting. The length of intensive care and hospital stay was significantly shorter, and early re-interventions were significantly reduced in the catheterisation group. There were eight deaths (17%); all within 35 days of the procedure. Of the survivors, only one has required a Fontan circulation. Twenty-eight patients (74%) have undergone biventricular repair and nine patients (24%) have one-and-a-half ventricle circulation. Following successful valvotomy, 80% of patients required further catheter-based or surgical interventions. CONCLUSIONS: A low threshold for initial interventional management yielded a high rate of successful biventricular circulations. Although mortality was low in patients who survived the peri-procedural period, the rate of re-intervention remained high in all groups.


Assuntos
Cateterismo Cardíaco/instrumentação , Ablação por Cateter/efeitos adversos , Cardiopatias Congênitas/cirurgia , Atresia Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Stents , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido , Tempo de Internação , Masculino , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
14.
J Am Coll Cardiol ; 75(11): 1266-1278, 2020 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-32192652

RESUMO

BACKGROUND: The superior sinus venosus atrial septal defect (SVASD) is characterized by deficiency of the common wall between the superior vena cava (SVC) and the right upper pulmonary vein (RUPV), which is no longer committed to the left atrium. OBJECTIVES: This study sought to evaluate the potential for redirecting the SVC and RUPV flow to the right and left atria, respectively, by implantation of a covered stent in the SVC. METHODS: Review of 48 consecutive adult SVASD patients undergoing assessment for correction. Pre-procedural evaluation included cross-sectional imaging and ex vivo simulation using printed or virtual 3-dimensional models. RESULTS: Transcatheter correction was performed in 25 patients, with a further 6 awaiting stent implantation. Only 8 patients were deemed technically unsuitable. The procedure involved balloon test inflation in the anticipated stent landing zone with simultaneous transesophageal echocardiography and pulmonary venography to confirm defect closure and unobstructed pulmonary venous drainage, followed by deployment of a 10-zig covered Cheatham platinum stent. Stents of lengths between 5 and 8 cm were implanted. A second, uncovered stent was used for anchoring in 9 patients. The RUPV was protected with a high-pressure balloon during stent implantation to prevent pulmonary venous obstruction in 4 patients. The median follow-up period was 1.4 (interquartile range: 0.8 to 1.7) years, with no mortality. Stent embolization occurred in 1 patient; another required drainage of hemopericardium. Cardiac computed tomography after 3 months confirmed unobstructed pulmonary venous return. At latest follow-up, a residual shunt was present in 1 patient. CONCLUSIONS: Transcatheter correction of SVASD may be considered as an alternative to surgery in a substantial proportion of patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Endovasculares/métodos , Comunicação Interatrial/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
16.
Postepy Kardiol Interwencyjnej ; 16(3): 244-261, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33597989

RESUMO

The foundation of wisdom is rooted in experience, and thus we reflexively call upon our senior leaders, mentors, coaches, and family members for guidance in our personal and professional lives. Witnessing the weathered perspectives of others allows for an internal audit of one's own strengths and deficiencies, which ultimately inspires personal growth. This experience is heightened when both the mentor and the mentee, for example, share a common goal. The field of congenital interventional cardiology, with its constant evolution and diverse technical approaches, requires a lifetime of learning, as well as safe passage of knowledge to the next generation. While there are published recommendations for what to consider when completing this task, hearing the sentiments of those with experience may be more profitable for future fellows and current interventionalists. In part one of a series, we hope to accomplish this goal by presenting an opportunity to learn from our experienced colleagues on the topic of congenital interventional cardiology training. Specifically, we aim to share expert opinions on how to succeed as a congenital interventional fellow, illustrate the diversity of teaching styles and expectations in various healthcare systems, and for the mid-career interventionalists, provide insight into the character traits of a successful mentor of interventional fellows.

17.
J Radiol Prot ; 40(1): 311-318, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31731286

RESUMO

We conducted a survey of doctors working in the cardiac catheterisation laboratories in Africa on their knowledge, attitude and practice with respect to radiation protection. Of seventy-two respondents contacted, 61 (84.7%) completed the questionnaire. Twenty-eight, (45.9%) were younger than 45 years. Thirty-seven, (60.6%) had less than 10 years of experience in the laboratory. Only 28 (45.9%) had undertaken radiation protection training. Fifty-eight, (95.1%) consistently used lead aprons. Forty-seven, (77%) reported consistently using thyroid shields. Ten (16.4%) consistently used radiation protection eyeglasses, whilst 36 (59%) never used them. Thermoluminescent Dosimeter badges were consistently used in 23 (37.7%). Forty-two, (68.9%) reported having ceiling mounted lead/acrylic shields. Level of radiation exposure in the most recent one year was ≤2 mSv in 14, between 2 and 20 mSv in 8 and between 20 and 30 mSv in 2, whilst 33 did not know their dose readings. The use of basic radiation protection tools as well as the knowledge and measurement of radiation exposure among interventional cardiologists working in Africa is low. The unavailability of some of the protective tools and a knowledge gap in terms of radiation protection and monitoring of self-exposure were some of the reasons for suboptimal self-protection against ionising radiation among our respondents. We suggest that initiatives be taken by all stakeholders to train this group of medical professionals in basic radiation protection to avoid unnecessary exposure to themselves, co-workers and patients.


Assuntos
Cardiologistas , Conhecimentos, Atitudes e Prática em Saúde , Proteção Radiológica , Radiologia Intervencionista , Adulto , Estudos Transversais , Etiópia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
18.
Front Pediatr ; 7: 250, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31294003

RESUMO

Congenital Heart Disease (CHD) is an enormous problem in Low Middle Income Countries and particularly in sub-Saharan Africa. There is an estimated 500,000 children born in Africa with CHD each year with a major proportion of this in sub-Saharan Africa. The vast majority of these children receive sub-optimal or no care at all. In East Africa: Kenya, Tanzania, and Uganda have all attempted to create a CHD service for the last 20 years with minimal success due to various factors. Visiting cardiac missions have made considerable contributions in the development of CHD services in these countries, however there remains a significant number of children with lack of care. We explore the positive aspects of the current projects, the various factors that hinder growth in this area, and what can be done to promote CHD service growth in these countries.

19.
Cardiol Young ; 29(8): 1009-1015, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31244446

RESUMO

The range and number of educational and networking events that are available for fellows, trainees, and junior faculty to attend grows every year. Each meeting useful in its own way; each adding value to the development and the growth of an interventionist. Within paediatric, congenital, and structural heart disease, three of the standout meetings are: Pediatric and Interventional Cardiac Symposium (PICS-AICS), Congenital and Structural Interventions (CSI), and International Workshop on Interventional Pediatric and Adult Congenital Cardiology (IPC). All of these were started by leaders in our field; people known to be passionate educators and innovators. International congresses focusing more broadly on congenital cardiac disease in children and adults are rare. These forums allow more interdisciplinary discussions between the interventionist, surgeon, and non-invasive specialists. Purely interventional meetings are essential to allow colleagues to debate and explore the nuances and intricacies of technique and approach, developing concepts to be challenged in wider forums. During the recent 21st PICS-AICS meeting Prof. Ziyad M. Hijazi, Shakeel A. Qureshi, Mario Carminati, and Dr Damien Kenny shared their time to engage in frank, recorded conversations which provide a unique insight in to the process and concepts behind three of our most important educational congresses.


Assuntos
Cardiologia , Congressos como Assunto , Pediatria , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Humanos , Sociedades Médicas
20.
Ann Pediatr Cardiol ; 12(2): 138-140, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31143040

RESUMO

Transseptal puncture is a routine technique to access the left atrium during catheter ablation, but carries a small risk of perforation into the pericardium or aorta. When conservative management fails, surgical repair is usually needed. We report an 81-year-old male in whom aortic root perforation occurred after transseptal puncture and was treated successfully by percutaneous deployment of an Amplatzer Duct Occluder II device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...