Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 275
Filtrar
2.
Infect Immun ; 86(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29158433

RESUMO

Bacillus cereus remains an important cause of infections, particularly in immunocompromised hosts. While typically associated with enteric infections, disease manifestations can be quite diverse and include skin infections, bacteremia, pneumonia, and meningitis. Whether there are any genetic correlates of bacterial strains with particular clinical manifestations remains unknown. To address this gap in understanding, we undertook whole-genome analysis of B. cereus strains isolated from patients with a range of disease manifestations, including noninvasive colonizing disease, superficial skin infections, and invasive bacteremia. Interestingly, strains involved in skin infection tended to form a distinct genetic cluster compared to isolates associated with invasive disease. Other disease manifestations, despite not being exclusively clustered, nonetheless had unique genetic features. The unique features associated with the specific types of infections ranged from traditional virulence determinants to metabolic pathways and gene regulators. These data represent the largest genetic analysis to date of pathogenic B. cereus isolates with associated clinical parameters.


Assuntos
Bacillus cereus/genética , Sequenciamento Completo do Genoma/métodos , Bacillus cereus/patogenicidade , Genoma Bacteriano/genética , Genótipo , Humanos , Hospedeiro Imunocomprometido , Filogenia
3.
AJNR Am J Neuroradiol ; 38(6): 1169-1176, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28408632

RESUMO

BACKGROUND AND PURPOSE: 4D DSA allows acquisition of time-resolved 3D reconstructions of cerebral vessels by using C-arm conebeam CT systems. The aim of our study was to evaluate this new method by qualitative and quantitative means. MATERIALS AND METHODS: 2D and 4D DSA datasets were acquired in patients presenting with AVMs, dural arteriovenous fistulas, and cerebral aneurysms. 4D DSA was compared with 2D DSA in a consensus reading of qualitative and quantitative parameters of AVMs (eg, location, feeder, associated aneurysms, nidus size, drainage, Martin-Spetzler Score), dural arteriovenous fistulas (eg, fistulous point, main feeder, diameter of the main feeder, drainage), and cerebral aneurysms (location, neck configuration, aneurysmal size). Identifiability of perforators and diameters of the injection vessel (ICA, vertebral artery) were analyzed in 2D and 4D DSA. Correlation coefficients and a paired t test were calculated for quantitative parameters. The effective patient dose of the 4D DSA protocol was evaluated with an anthropomorphic phantom. RESULTS: In 26 patients, datasets were acquired successfully (AVM = 10, cerebral aneurysm = 10, dural arteriovenous fistula = 6). Qualitative and quantitative evaluations of 4D DSA in AVMs (nidus size: r = 0.99, P = .001), dural arteriovenous fistulas (diameter of the main feeder: r = 0.954, P = .03), and cerebral aneurysms (aneurysmal size: r = 1, P = .001) revealed nearly complete accordance with 2D DSA. Perforators were comparably visualized with 4D DSA. Measurement of the diameter of the injection vessel in 4D DSA was equivalent to that in 2D DSA (P = .039). The effective patient dose of 4D DSA was 1.2 mSv. CONCLUSIONS: 4D DSA is feasible for imaging of AVMs, dural arteriovenous fistulas, and cerebral aneurysms. 4D DSA offers reliable visualization of the cerebral vasculature and may improve the understanding and treatment of AVMs and dural arteriovenous fistulas. The number of 2D DSA acquisitions required for an examination may be reduced through 4D DSA.


Assuntos
Angiografia Digital/métodos , Encéfalo/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Clin Neuroradiol ; 27(1): 43-49, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26104272

RESUMO

OBJECTIVE: Knowledge on the influence of 2D and 3D coils to occlude intracranial aneurysms is poor. Therefore, aim of our analysis was to evaluate whether the use of 3-D versus 2-D coils alone may improve the efficacy of endovascular aneurysm treatment. PATIENTS AND METHODS: We performed a matched pair analysis comparing aneurysms treated by 3-D coils as initial "framing" coils to aneurysms treated exclusively by 2-D coils. Number of coils, implanted coil length/volume, and associated packing density were calculated. Aneurysmal occlusion was assessed and monitored 6 months (DSA; magnetic resonance angiography (MRA)) and 18 months (MRA) after embolization. Periprocedural complications and retreatment rate of each group were analyzed. RESULTS: Our retrospective analysis revealed 50 pairs. Concerning the 3-D group, number of coils (353 in total, median 7; p = 0.002), implanted coil length (55.69 ± 48.4 cm), implanted coil length per volume (5.92 mm/mm3), and packing density (30 %; p = 0.017) was higher than in the 2-D group (259 in total, median 5 coils; 38.52 ± 43.13 cm; 4.54 mm/mm3; 23 %). Occlusion was not significantly different immediately after treatment but at 6 and 18 months follow-up in favor of 3-D coils. Retreatment was performed in 2 cases of the 3-D group and in 3 cases of the 2-D group and therefore in a similar range (p = 0.564). CONCLUSION: Initial use of 3-D coils revealed a higher packing density and a higher long-term occlusion. Therefore, we recommend initial use of 3-D coils.


Assuntos
Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/estatística & dados numéricos , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/cirurgia , Complicações Pós-Operatórias/epidemiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Alemanha/epidemiologia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Estudos Longitudinais , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Estudos Retrospectivos , Resultado do Tratamento
6.
Physiol Res ; 63(2): 157-65, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24397800

RESUMO

The concept of vena contracta space reduction in tricuspid valve position was tested in an animal model. Feasibility of specific artificial obturator body (REMOT) fixed to the right ventricular apex and interacting with tricuspid valve leaflets was evaluated in three different animal studies. Catheter-based technique was used in three series of experiment in 7 sheep. First acute study was designed for evaluation if the screwing mode of guide wire anchoring to the right ventricular apex is feasible for the whole REMOT body fixing. Longer study was aimed to evaluate stability of the REMOT body in desired position when fixing the screwing wire on its both ends (to the right ventricular apex and to the skin in the neck area). X-ray methods and various morphological methods were used. The third acute study was intended to the REMOT body deployment without any fixing wire. In all of 7 sheep the REMOT was successfully inserted into the right heart cavities and then fixed to the right ventricular apex area. When the REMOT was left in situ more than 6 months it was stable, induced adhesion to the tricuspid valve leaflet and was associated with a specific cell invasion. Releasing of the REMOT from the guiding tools was also successfully verified. Deployment of the obturator body in the aim to reduce the tricuspid valve orifice is feasible and well tolerated in the short and longer term animal model. Specific cell colonization including neovascularization of the obturator body was observed.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/patologia , Insuficiência da Valva Tricúspide/cirurgia , Animais , Estudos de Viabilidade , Projetos Piloto , Ovinos , Valva Tricúspide/patologia , Valva Tricúspide/cirurgia
7.
Clin Neuroradiol ; 23(2): 113-20, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23241650

RESUMO

PURPOSE: Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. METHODS: We enrolled 16 patients with angiographically proven CCFs. Endovascular treatment was performed in 14 cases. For postprocessing of digital subtraction angiography (DSA) series, a newly implemented algorithm of parametric color coding was used, turning sequential images of two-dimensional (2D)-DSA series into a single color-coded image. Angiographic data of initial, interventional, and postinterventional 2D-DSA series were compared with color-coded images. Whether parametric color coding could facilitate evaluation of fistula architecture and provide a more precise estimation of fistula venous drainage patterns as well as whether flow analysis could reveal objective changes during and after treatment were investigated. RESULTS: In 56 % of the cases, parametric color coding was observed to facilitate visualization of fistula angioarchitecture. Estimation of fistula drainage flow patterns was considered to be improved in 31 % of the cases. For assessment of hemodynamic changes during and after treatment, parametric color coding was assumed to be helpful in 21 % of the cases, especially because revealing flow changes that were not visible on 2D-DSA series were now visible. CONCLUSIONS: Parametric color coding is a fast application tool that might provide additional support in the angiographic evaluation of CCFs. Visualization of complex fistula architecture could be facilitated, and flow analysis might improve assessment of venous drainage patterns, thereby increasing overall diagnostic confidence. During and after treatment, hemodynamic changes that were not visible on 2D-DSA series could now be depicted.


Assuntos
Algoritmos , Angiografia Digital/métodos , Fístula Carótido-Cavernosa/diagnóstico por imagem , Cor , Gráficos por Computador , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador
8.
AJNR Am J Neuroradiol ; 33(7): 1251-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22403774

RESUMO

BACKGROUND AND PURPOSE: High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC. MATERIALS AND METHODS: Forty-seven patients with NVC, trigeminal neuralgia, hemifacial spasm, and glossopharyngeal neuralgia were examined at 1.5T and 3T, including high-resolution 3D-CISS and 3D-TOF MRA sequences. Delineation of anatomic structures, overall image quality, severity of artifacts, visibility of NVC, and assessment of the SNR and CNR were compared between field strengths. RESULTS: SNR and CNR were significantly higher at 3T (P < .001). Significantly better anatomic conspicuity, including delineation of CNs, nerve branches, and assessment of small vessels, was obtained at 3T (P < .02). Severity of artifacts was significantly lower at 3T (P < .001). Consequently, overall image quality was significantly higher at 3T. NVC was significantly better delineated at 3T (P < .001). Six patients in whom NVC was not with certainty identifiable at 1.5T were correctly diagnosed at 3T. CONCLUSIONS: Patients with NVC may benefit from the higher resolution and greater sensitivity of 3T for preoperative assessment of NVC, and 3T may be of particular value when 1.5T is equivocal.


Assuntos
Doenças do Nervo Glossofaríngeo/patologia , Espasmo Hemifacial/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Síndromes de Compressão Nervosa/patologia , Neuralgia do Trigêmeo/patologia , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síndrome
9.
Thorac Cardiovasc Surg ; 53(5): 261-6, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16208610

RESUMO

Setting up a reliable cost unit accounting system in a hospital is a fundamental necessity for economic survival, given the current general conditions in the healthcare system. Definition of a suitable cost unit is a crucial factor for success. We present here the development and use of a clinical pathway as a cost unit as an alternative to the DRG. Elective coronary artery bypass grafting was selected as an example. Development of the clinical pathway was conducted according to a modular concept that mirrored all the treatment processes across various levels and modules. Using service records and analyses the process algorithms of the clinical pathway were developed and visualized with CorelTM iGrafix Process 2003. A detailed process cost record constituted the basis of the pathway costing, in which financial evaluation of the treatment processes was performed. The result of this study was a structured clinical pathway for coronary artery bypass grafting together with a cost calculation in the form of cost unit accounting. The use of a clinical pathway as a cost unit offers considerable advantages compared to the DRG or clinical case. The variance in the diagnoses and procedures within a pathway is minimal, so the consumption of resources is homogeneous. This leads to a considerable improvement in the value of cost unit accounting as a strategic control instrument in hospitals.


Assuntos
Contabilidade/economia , Procedimentos Clínicos/economia , Algoritmos , Benchmarking/economia , Ponte de Artéria Coronária/economia , Custos e Análise de Custo , Grupos Diagnósticos Relacionados/economia , Planos de Pagamento por Serviço Prestado/economia , Administração Financeira de Hospitais/economia , Cardiopatias/economia , Cardiopatias/cirurgia , Humanos
10.
Artigo em Inglês | MEDLINE | ID: mdl-16754151

RESUMO

The aim of this study was the evaluation of preliminary suitability of the piglet small intestinal submucosa (SIS) sandwich Zilver endograft for experimental transjugular intrahepatic portosystemic shunt (TIPS) creation. TIPS was created in six swine. The five surviving animals underwent the follow-up portogram and were sacrificed at four weeks after TIPS creation. Gross and histologic examination was performed in all animals. TIPS creation was successful in all animals. One animal died four days after TIPS creation. In the five surviving animals, one shunt was occluded and four shunts were stenosed on the follow-up portogram. The mean percentage narrowing of the most advanced stenoses was 72% (range, 60%-100%). The most advanced stenosis was located in the parenchymal tract in three shunts and in the hepatic vein portion in one shunt. Gross and histologic examination showed abundant neointimal formation composed mainly of fibroblasts leading to the significant shunt stenoses. The piglet SIS sandwich Zilver stent-graft was found to offer only limited TIPS patency and should not be used for the definitive long-term TIPS study.

11.
Phys Rev Lett ; 89(3): 033004, 2002 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-12144390

RESUMO

We have measured fully differential cross sections for photo double ionization of helium 450 eV above the threshold. We have found an extremely asymmetric energy sharing between the photoelectrons and an angular asymmetry parameter beta approximately 2 and beta approximately 0 for the fast and slow electrons, respectively. The electron angular distributions show a dominance of the shakeoff for 2 eV electrons and clear evidence of an inelastic electron-electron scattering at an electron energy of 30 eV. The data are in excellent agreement with convergent close-coupling calculations.

12.
Phys Rev Lett ; 88(7): 073002, 2002 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-11863892

RESUMO

We have measured the angular distributions of 1s photoelectrons excited by circularly and linearly polarized light from fixed-in-space CO and N2 molecules, in the vicinity of their shape resonances. A strong circular dichroism, i.e., a strong dependence on the sense of rotation of the polarization vector of the photons, is found for both molecules. State-of-the-art one-electron multiple scattering and partially correlated random phase approximation calculations are in good agreement with many, but not all, aspects of the experimental data.

13.
Cardiovasc Intervent Radiol ; 24(2): 99-105, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11443394

RESUMO

PURPOSE: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material. METHODS: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed. RESULTS: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks. CONCLUSION: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted.


Assuntos
Angioplastia , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Mucosa Intestinal/transplante , Intestino Delgado/transplante , Animais , Aneurisma da Aorta Abdominal/etiologia , Aneurisma da Aorta Abdominal/patologia , Ruptura Aórtica/etiologia , Ruptura Aórtica/patologia , Autopsia , Cateterismo/efeitos adversos , Modelos Animais de Doenças , Seguimentos , Mucosa Intestinal/anatomia & histologia , Intestino Delgado/anatomia & histologia , Projetos Piloto , Ovinos , Resultado do Tratamento
15.
World J Surg ; 25(3): 337-45; discussion 345-6, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11343189

RESUMO

During the 13 years since its introduction into clinical practice, transjugular intrahepatic portosystemic shunt (TIPS) has become widely accepted worldwide as a percutaneous, interventional procedure for treating complications of portal hypertension. An experienced, skillful team, however, is necessary to ensure the high technical success of TIPS and to avoid its potential procedural complications. Presently, TIPS is used mainly for treatment of acute or recurrent hemorrhage from gastroesophageal varices refractory to endoscopic therapy. Randomized studies have shown that it is more effective than endoscopic treatment for preventing rebleeding; however, it is associated with a higher incidence of encephalopathy. Both treatments produce comparable survival rates. TIPS is also effective in the treatment of hepatogenic ascites and hydrothorax and hepatorenal syndrome. In comparison with surgical shunts, TIPS is a significantly less invasive procedure that can be done in poor surgical candidates with advanced cirrhosis. The high rate of shunt obstructions seen with TIPS mandates close surveillance and maintenance, rendering TIPS a multistage procedure. This is a major disadvantage of TIPS compared to surgery. Presently, both TIPS and surgical shunts have their place in the treatment of gastroesophageal variceal hemorrhage unresponsive to endoscopic therapy. TIPS is most suited for class B and C patients, particularly those who are candidates for liver transplantation. Surgical shunts should be considered for patients with well preserved liver function. Large, randomized controlled studies should be done to compare these treatment methods. Animal experimental and early clinical studies using covered stents (stent-grafts) are promising for the prevention of shunt obstructions and thus converting TIPS from a multistage to a one-stage procedure.


Assuntos
Varizes Esofágicas e Gástricas/cirurgia , Hemorragia Gastrointestinal/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática , Animais , Contraindicações , Endoscopia Gastrointestinal , Humanos , Transplante de Fígado , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Resultado do Tratamento
16.
Hepatogastroenterology ; 48(38): 475-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11379337

RESUMO

BACKGROUND/AIMS: Prehepatic portal hypertension caused by extrahepatic portal vein occlusion is a situation in which hepatocytes are not damaged by disease despite the fact that portal blood is unable to reach them due to portal vein occlusion. We explored the patency of intrahepatic portal vein branches after extrahepatic portal vein occlusion for the possibility of revascularization by splenoportal shunt. METHODOLOGY: Prehepatic portal hypertension was induced in 8 mini-pigs by external compression of the portal vein with a device consisting of an inflatable silicone balloon mounted on a silicone cuff and attached to a subcutaneous chamber. Another device consisting of cannula and a subcutaneous chamber was placed into the splenic vein for portal pressure monitoring and portal venograms. Both devices were placed during laparotomy with their chambers positioned subcutaneously. Portal vein compression was initiated one week later and was accomplished in two steps. Extrahepatic portal vein occlusion and the patency of intrahepatic portal vein branches were confirmed by direct portal venography. Alteration of the intrahepatic portal bed was examined at necropsy after 4 weeks, checking for the presence of occlusion or thrombosis. RESULTS: Portal vein occlusion was achieved in 5 animals, while severe stenosis was demonstrated in the remaining three. Portal venograms demonstrated patency of the lobar portal vein branches filled by hepatopetal collaterals around the occluded portal vein. All intrahepatic branches were free of thrombus at gross examination. CONCLUSIONS: In the absence of the hepatic parenchymal disease, lobar intrahepatic portal vein branches remain patent despite truncal portal vein occlusion and are supplied by rapidly developed hepatopetal collaterals.


Assuntos
Hipertensão Portal/fisiopatologia , Sistema Porta/fisiopatologia , Grau de Desobstrução Vascular , Animais , Circulação Colateral , Constrição Patológica , Modelos Animais de Doenças , Veia Porta/patologia , Portografia , Suínos , Porco Miniatura
17.
J Vasc Interv Radiol ; 12(3): 359-64, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11287515

RESUMO

PURPOSE: To evaluate a new, low profile, home-made, bifurcated drum occluder endograft (BDOEG), designed for percutaneous, transcatheter treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: AAA was created in 10 dogs with over-dilated Palmaz stents. To prevent back filling, the lumbar arteries, inferior mesenteric artery, and common internal iliac arteries were embolized. The BDOEG was constructed of a drum occluder device and two PTFE endografts. The drum device consisted of a modified Z stent with Dacron stretched across and held within the ends of the stent, each with two 8 x 6-mm slits through which PTFE endografts were delivered. The PTFE endografts were 8 mm in diameter and 9.5 cm in length. Preloaded, the BDOEG was delivered through a 10-F sheath from both femoral arteries in a three-step procedure. All 10 animals were treated with BDOEG. Aortography was performed immediately, 6 weeks, and 12 weeks after stent-graft placement. Five animals were killed at 6 weeks and five were killed at 3 months. Gross and histologic evaluation was performed. RESULTS: The infrarenal aortic diameters and both external iliac arteries ranged from 8.0 mm to 10.3 mm (mean, 9.4 mm +/- 0.6) and from 5.2 mm to 6.8 mm (mean, 5.8 mm +/- 0.5), respectively. Creation of the AAA was successful in all 10 dogs. AAA diameters ranged from 13.7 mm to 15.9 mm (mean, 14.9 mm +/- 0.7). Complete exclusion of the AAA was achieved immediately after BDOEG placement and aneurysms remained excluded without perigraft leak to the time of killing in all 10 animals. There was a high incidence of aortoiliac limb occlusion. Occlusion of 12 aortoiliac limbs (60%) caused by intimal hyperplasia at the distal end of the endografts in iliac arteries developed in nine animals (90%). In six animals (60%), one limb occluded and, in three animals (30%), there was occlusion of both limbs. CONCLUSION: This study suggests a new approach for treatment of AAA. BDOEG use reduces sheath size for endograft delivery and may eliminate the need for a surgical cut down on femoral arteries. Tapering of the iliac ends of endografts to the size of the artery will be needed to prevent distal intimal hyperplasia.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Implante de Prótese Vascular , Implantes Experimentais , Stents , Animais , Prótese Vascular , Cães , Desenho de Equipamento , Polietilenotereftalatos , Politetrafluoretileno
18.
J Vasc Interv Radiol ; 12(3): 385-7, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11287520

RESUMO

Primary hyperaldosteronism is a potential cause of hypertension. Unilateral adrenal adenoma and bilateral adrenal cortical hyperplasia are the most common causes of primary hyperaldosteronism. Adrenal venous sampling is employed as the gold standard test to differentiate between these two different causes when the results of other studies in the work-up protocol are non-diagnostic or ambiguous. Adrenal venous sampling can be a challenging procedure, especially in the presence of anomalous venous drainage patterns. Knowledge of normal adrenal venous anatomy, as well as possible variants, is therefore important to ensure a successful procedure. The authors describe an unusual variant of left adrenal venous drainage directly into the IVC.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Veias/anormalidades , Veia Cava Inferior/anormalidades , Doenças das Glândulas Suprarrenais/complicações , Doenças das Glândulas Suprarrenais/diagnóstico , Coleta de Amostras Sanguíneas , Diagnóstico Diferencial , Humanos , Hiperaldosteronismo/etiologia , Masculino , Pessoa de Meia-Idade
19.
J Vasc Interv Radiol ; 12(4): 475-86, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11287535

RESUMO

PURPOSE: To determine the feasibility of the creation of a direct intrahepatic inferior vena cava (IVC)-to-portal-vein shunt with puncture guided by a transfemorally placed intravascular ultrasound (IVUS) probe and use of a polytetrafluoroethylene (PTFE)-covered stent-graft. MATERIALS AND METHODS: In five swine, transjugular access was used to perform a direct puncture from the IVC to the portal vein with use of a modified Rosch-Uchida Portal Access set directed with real-time IVUS (9 MHz) introduced from a transfemoral venous approach. The direct intrahepatic portocaval shunt (DIPS) was then created with single or overlapping PTFE-covered Palmaz stents placed through a 10-F sheath and dilated to a diameter of 8 mm. Follow-up was performed with transhepatic portography at 2, 4, and 8 weeks. Animals were killed when shunts occluded or at the termination of the study at 8 weeks. Gross and microscopic histologic study was performed on sacrificed animals. A similar technique was used to create DIPS in five patients with intractable ascites, with follow-up by US and venography. RESULTS: All experimental DIPS created in swine were created without complications. Portal vein punctures were achieved in four of five swine on the first or second pass of the needle. Follow-up transhepatic portography at 2 weeks demonstrated occlusion of two shunts, both explained by technical reasons at sacrifice. At 4 and 8 weeks, the remaining three shunts were patent on portography. Histology showed a thin neointimal lining with no significant tissue ingrowth or hyperplasia. Clinically, in five patients, successful puncture of the portal vein from the IVC was achieved in one to three passes. Creation of DIPS led to a reduction of mean portosystemic gradient from 18-29 mm Hg (mean, 24 mm Hg) to 9-10 mm Hg (mean, 9 mm Hg). One patient died of liver failure 2 days after creation of DIPS. The other four patients were doing well 2-15 months (mean, 8 months) after the procedure, with patency confirmed by US and venography. CONCLUSION: Creation of DIPS is technically feasible, and the direct IVC-to-portal-vein puncture can be done accurately with real-time IVUS guidance. Further studies and longer follow-up are necessary to determine if the short length of the PTFE-covered stent-graft and avoidance of the hepatic vein will increase the long-term patency compared to standard transjugular intrahepatic portosystemic shunt creation.


Assuntos
Politetrafluoretileno , Derivação Portocava Cirúrgica/métodos , Stents , Ultrassonografia de Intervenção , Animais , Ascite/cirurgia , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Derivação Portocava Cirúrgica/efeitos adversos , Derivação Portocava Cirúrgica/instrumentação , Veia Porta , Punções , Stents/efeitos adversos , Suínos , Resultado do Tratamento , Grau de Desobstrução Vascular
20.
J Vasc Interv Radiol ; 12(2): 235-45, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11265889

RESUMO

PURPOSE: To evaluate the effects of catheter-directed thrombin in the peripheral arterial circulation of swine. MATERIALS AND METHODS: Thrombin was injected into a single femoral artery in 20 domestic swine. Each of five animals from four dose groups received 50, 150, 250, or 1,000 U as a single dose. Bilateral femoral arterial flow was monitored for as long as 4 hours and evaluated relative to baseline and contralateral limb flow. Interval arteriographic results were evaluated by segmental patency and a numeric angiographic score. RESULTS: Mean baseline flow was 136 mL/min +/- 44, with an internal arterial diameter of 3.4 mm +/- 0.5. A transient increase in blood flow after thrombin administration was followed by diminished flow and thrombosis. These findings varied directly with dose and inversely with baseline flow. Angiographic and flow abnormalities generally improved with time and recovery was generally better in swine that received 50 or 1,000 U than in other groups. However, one animal that received 1,000 U (13.2 U/mL/min) developed stable, complete limb thrombosis. The degree of recovery varied with thrombin dose and thrombus location. At doses greater than 50 U (0.33 U/mL/min +/- 0.05), abnormalities were commonly persistent. Animals receiving the 150-U dose (1.33 U/mL/min +/- 0.41) had a higher incidence of persistent distal occlusion. Distal occlusions were less likely to resolve than proximal occlusions. CONCLUSIONS: The effect of intraarterial thrombin is directly related to dose and inversely related to baseline blood flow. In swine, a threshold for significant flow disruption and thrombosis exists above a dose of 50 U (0.33 U/mL/min +/- 0.05). A threshold dose for irreversible occlusion may also exist. Although small amounts of thrombin in a high-flow vessel may not cause significant complication, administration into the arterial circulation should be avoided.


Assuntos
Fluxo Sanguíneo Regional/efeitos dos fármacos , Trombina/farmacologia , Angiografia , Angiografia Digital , Animais , Relação Dose-Resposta a Droga , Artéria Femoral , Injeções Intra-Arteriais , Suínos , Trombina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...