Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dent Mater ; 23(11): 1390-6, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17207525

RESUMO

PURPOSE: Investigation of laser-induced fluorescence of an experimental pigment (Flu) to discriminate between a filling and the tooth and its influence on the material properties of experimental dental composites. MATERIALS AND METHODS: Three experimental composites (EC) were manufactured. The standard contained no Flu, Flu-0.5 contained 0.5%, Flu-1.0 contained 1%. To judge the extent of fluorescence, specimens and fillings placed in natural teeth were irradiated with an infrared laser (980 nm, 120 mW). Flexural strength, modulus of elasticity, depth of cure, water sorption, solubility, and color (CIE-L(*)a(*)b(*)-values) were measured to investigate the influence of Flu on EC. ANOVA was calculated and the statistical significance was p < 0.05. RESULTS: Strong laser-induced green fluorescence was observed so that fillings and tooth structures were clearly discriminated. No influence of Flu on flexural strength and modulus of elasticity occurred. Water sorption and solubility were far below the limits of EN ISO 4049. Increasing Flu concentrations revealed minor but significant reduction of depth of cure, shifts to more white and red and less yellow. SIGNIFICANCE: Flu provides laser-induced fluorescence allowing an easy discrimination between fillings and teeth. Flu did not severely influence the material properties.


Assuntos
Resinas Compostas , Corantes Fluorescentes , Absorção , Restauração Dentária Permanente , Análise do Estresse Dentário , Elasticidade , Fluorescência , Raios Infravermelhos , Lasers , Maleabilidade , Solubilidade , Dente
2.
Dent Mater ; 23(6): 696-704, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16899289

RESUMO

PURPOSE: To investigate the influence of a halogen light curing device used with constant or exponential polymerization mode on the color stability of contemporary resin-based filling materials. MATERIALS AND METHODS: Eight samples of Charisma (CH), Durafill (DU), Definite (DE), and Dyract AP (DY) each were light-cured with constant power or with soft-start mode (Translux Energy) for 20, 40 or 60s. The CIE-Lab-values (L(*), a(*), b(*)) were measured prior to and after performing dry aging, water aging or a Suntest (EN ISO 7491) and Delta L-, Delta a-, Delta b-, and Delta E-values were calculated. RESULTS: Statistical analysis (GLM and repetition of measures) showed significant changes (p<0.05) of the color values for each material's curing mode and time after each of the aging processes. Four-way ANOVA revealed significant differences (p<0.05) between Delta L-, Delta a-, Delta b-, and Delta E of the materials in dependence on the curing time and mode and aging condition. Exponentially-cured DU was the most color-unstable material after aging in water followed by the 20s exponentially cured DE and CH samples. After the Suntest, DY showed significant bleaching (negative Delta b) and the largest Delta E for all curing times and modes followed by the DE samples. DU and CH were the most color-stable materials in this test. SIGNIFICANCE: The extent of discoloration depends on the (a) curing time, (b) curing mode, (c) aging condition, and (d) material. For the constant curing mode, 40s curing time for the exponential 60s seems to be appropriate.


Assuntos
Resinas Compostas/efeitos da radiação , Análise de Variância , Cor , Resinas Compostas/química , Restauração Dentária Permanente , Armazenamento de Medicamentos , Halogênios , Luz , Modelos Lineares , Teste de Materiais , Transição de Fase , Fatores de Tempo
3.
Dent Mater ; 22(12): 1103-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16406120

RESUMO

OBJECTIVE: Evaluation of flexural strengths and flexural moduli of hybrids, packables, ormocers, compomers and flowables prior to, and after, thermocycling. MATERIALS AND METHODS: Twenty specimens, size (25 +/- 2) mm x (2 +/- 0.1) mm x (2+/-0.1) mm, of Herculite (HE), Point 4 (P4), TetricCeram (TC), Miris (MI), TetricCeram HB, (HB), Solitaire 2 (SO), Surefil A (SU), Definte (DE), Admira (AD), Dyract AP (DY), Compoglass (CO) and TetricFlow (TF) were made according to ISO 4049. A three-point-bending test was carried out for the first 10 specimens after 24 h water storage at 37 degrees C and for the second 10 specimens after 30-day water storage at 37 degrees C, followed by 5000 thermocycles between +5 and +55 degrees C. For each test series flexural strengths and flexural moduli were calculated. Statistical significance was p < 0.05. RESULTS: Flexural strengths of DY and CO missed the 80 MPa limit of ISO 4049 for occlusal fillings prior to and after thermocycling. AD missed it after thermocycling. HE, P4, TC, MI, HB, SO, SU, DE and TF did not significantly differ prior to and after thermocycling. Flexural strength of SO and AD significantly decreased after thermocycling. No change of the flexural moduli could be observed for any of the test materials. Only SU exceeded 10,000 MPa prior to and after thermocycling. SIGNIFICANCE: Only DY and CO missed the flexural strength limit of ISO 4049 for occlusal fillings. Only SU exceeded a flexural modulus of 10,000 MPa prior to and after thermocycling.


Assuntos
Compômeros , Resinas Compostas , Análise de Variância , Restauração Dentária Permanente , Análise do Estresse Dentário , Elasticidade , Temperatura Alta , Teste de Materiais , Maleabilidade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...