Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 27(12): 2330-7, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16856126

RESUMO

CE methods have been developed for the determination of taurine in pharmaceutical formulation (microemulsion) and in biological media such as sweat. The CE system with end-column pulsed amperometric detection has been found to be an interesting method in comparison with UV and fluorescence detection for its simplicity and rapidity. A gold-disk electrode of 100 mm diameter was used as the working electrode. The effects of a field decoupler at the end of the capillary, separation voltage, injection and pressure times were investigated. A detection limit of 4 x 10(-5) mol/L was reached using integrated pulsed amperometric detection, a method successfully applied to taurine analysis of the biological samples such as sweat. For taurine analysis of oil-in-water microemulsion, fluorescence detector was the favored method, the detection limit of which was 4 x 10(-11) mol/L.


Assuntos
Eletroforese Capilar/métodos , Suor/química , Taurina/análise , Eletrodos , Ouro/química , Humanos , Veículos Farmacêuticos , Sensibilidade e Especificidade
2.
Rapid Commun Mass Spectrom ; 17(6): 576-82, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12621620

RESUMO

A new method for the identification of oligosaccharides obtained by enzymatic digestion of hyaluronic acid (HA) with bacterial hyaluronidase (HA lyase, E.C. 4.2.2.1, from Streptococcus agalactiae) using online capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS) is presented. A fused-silica capillary coated with polyacrylamide was used with a 40 mM ammonium acetate buffer at pH 9.0 and a separation voltage of +30 kV applied to the inlet. Separation was achieved for oligosaccharides containing 4-16 monomers. The migration behavior follows the chain length of the oligomers, regardless of charge state. However, no linear relationship was found for the relation between mobility and chain length. Using an ion trap mass analyzer, complementary structural information was obtained by MS/MS and MS(n) experiments.


Assuntos
Eletroforese Capilar/métodos , Ácido Hialurônico/química , Oligossacarídeos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Ácido Hialurônico/metabolismo , Hialuronoglucosaminidase/metabolismo , Estrutura Molecular , Oligossacarídeos/metabolismo , Streptococcus agalactiae/enzimologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...