Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circulation ; 133(15): 1472-83; discussion 1483, 2016 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-26969758

RESUMO

BACKGROUND: This randomized controlled trial evaluated clinical durability of Zilver PTX, a paclitaxel-coated drug-eluting stent (DES), for femoropopliteal artery lesions. Outcomes compare primary DES versus percutaneous transluminal angioplasty (PTA), overall DES (primary and provisional) versus standard care (PTA and provisional Zilver bare metal stent [BMS]), and provisional DES versus provisional BMS. METHODS AND RESULTS: Patients with symptomatic femoropopliteal artery disease were randomly assigned to DES (n=236) or PTA (n=238). Approximately 91% had claudication; 9% had critical limb ischemia. Patients experiencing acute PTA failure underwent secondary randomization to provisional BMS (n=59) or DES (n=61). The 1-year primary end points of event-free survival and patency showed superiority of primary DES in comparison with PTA; these results were sustained through 5 years. Clinical benefit (freedom from persistent or worsening symptoms of ischemia; 79.8% versus 59.3%, P<0.01), patency (66.4% versus 43.4%, P<0.01), and freedom from reintervention (target lesion revascularization, 83.1% versus 67.6%, P<0.01) for the overall DES group were superior to standard care in nonrandomized comparisons. Similarly, clinical benefit (81.8% versus 63.8%, P=0.02), patency (72.4% versus 53.0%, P=0.03), and freedom from target lesion revascularization (84.9% versus 71.6%, P=0.06) with provisional DES were improved over provisional BMS. These results represent >40% relative risk reduction for restenosis and target lesion revascularization through 5 years for the overall DES in comparison with standard care and for provisional DES in comparison with provisional BMS. CONCLUSIONS: The 5-year results from this large study provide long-term information previously unavailable regarding endovascular treatment of femoropopliteal artery disease. The Zilver PTX DES provided sustained safety and clinical durability in comparison with standard endovascular treatments. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00120406.


Assuntos
Angioplastia , Arteriopatias Oclusivas/terapia , Stents Farmacológicos , Artéria Femoral , Paclitaxel/uso terapêutico , Artéria Poplítea , Adulto , Idoso , Anticoagulantes/uso terapêutico , Arteriopatias Oclusivas/tratamento farmacológico , Aspirina/uso terapêutico , Clopidogrel , Terapia Combinada , Progressão da Doença , Intervalo Livre de Doença , Falha de Equipamento , Feminino , Artéria Femoral/efeitos dos fármacos , Seguimentos , Humanos , Claudicação Intermitente/terapia , Isquemia/cirurgia , Isquemia/terapia , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Artéria Poplítea/efeitos dos fármacos , Recidiva , Stents , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Grau de Desobstrução Vascular
2.
J Endovasc Ther ; 21(5): 644-53, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25290792

RESUMO

PURPOSE: To report a subgroup analysis comparing safety and effectiveness outcomes in Japanese and non-Japanese patients as part of a prospective, multinational, randomized controlled trial (ClinicalTrials.gov identifier NCT00120406) evaluating a paclitaxel-coated drug-eluting stent (DES) compared to percutaneous transluminal angioplasty (PTA) for treating peripheral artery disease. METHODS: Patients were randomly assigned to primary DES or PTA. In the Japanese cohort, 27 patients (21 men; mean age 71.2±9.6 years) were randomized to PTA and 25 patients (19 men; mean age 69.8±10.2 years) to primary DES. In the non-Japanese cohort, 211 patients (131 men; mean age 67.3±10.6 years) were randomized to PTA and 211 patients (136 men; mean age 67.6±9.5 years) to primary DES. Outcome measures included event-free survival (EFS), freedom from target lesion revascularization (TLR), patency, stent fracture, and sustained clinical benefit through 2 years. RESULTS: Safety and effectiveness outcomes were similar in the Japanese and non-Japanese cohorts, although the outcomes in the Japanese cohort treated with primary DES were numerically better. In the DES group, the 2-year EFS was 92.0% vs. 85.0% (p=0.61), freedom from TLR was 96.0% vs. 85.5% (p=0.55), primary patency was 80.0% vs. 74.3% (p=0.61), and clinical benefit was sustained in 88.5% vs. 80.5% of patients (p=0.31) in the Japanese and non-Japanese cohorts, respectively. Stent fractures were seen in 4 of 457 stents at 12 months: 3 in the Japanese cohort and 1 in the non-Japanese cohort. CONCLUSION: The subgroup analysis comparing Japanese and non-Japanese patients supports the safety and effectiveness of the paclitaxel-coated DES in Japanese patients with stenotic lesions in the femoropopliteal arteries. The lack of major differences associated with ethnicity in these 2-year outcomes supports the validity and value of multinational clinical trials.


Assuntos
Angioplastia com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Artéria Femoral , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Constrição Patológica , Intervalo Livre de Doença , Feminino , Artéria Femoral/fisiopatologia , Alemanha , Humanos , Japão , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reprodutibilidade dos Testes , Projetos de Pesquisa , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
3.
J Endovasc Ther ; 18(5): 613-23, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21992630

RESUMO

PURPOSE: To report a prospective, single-arm, multicenter clinical study evaluating the Zilver PTX drug-eluting stent for treating the above-the-knee femoropopliteal segment (NCT01094678; http://www.clinicaltrials.gov ). METHODS: The Zilver PTX drug-eluting stent is a self-expanding nitinol stent with a polymer-free paclitaxel coating. Patients with symptomatic (Rutherford category 2-6) de novo or restenotic lesions (including in-stent stenosis) of the above-the-knee femoropopliteal segment were eligible for enrollment. Between April 2006 and June 2008, 787 patients (578 men; mean age 66.6±9.5 years) were enrolled at 30 international sites. RESULTS: Nine hundred lesions (24.3% restenotic lesions of which 59.4% were in-stent stenoses) were treated with 1722 Zilver PTX stents; the mean lesion length was 99.5±82.1 mm. The 12-month Kaplan-Meier estimates included an 89.0% event-free survival rate, an 86.2% primary patency rate, and a 90.5% rate of freedom from target lesion revascularization. There were no paclitaxel-related adverse events reported. The 12-month stent fracture rate was 1.5%. The ankle-brachial index, Rutherford score, and walking distance/speed scores significantly improved (p<0.001) from baseline to 12 months. CONCLUSIONS: These results indicate that the Zilver PTX drug-eluting stent is safe for treatment of patients with de novo and restenotic lesions of the above-the-knee femoropopliteal segment. At 1 year, the overall anatomical and clinical effectiveness results suggest that this stent is a promising endovascular therapy.


Assuntos
Ligas , Arteriopatias Oclusivas/terapia , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Procedimentos Endovasculares/instrumentação , Artéria Femoral , Paclitaxel/administração & dosagem , Artéria Poplítea , Idoso , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Canadá , Constrição Patológica , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Recidiva , República da Coreia , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
Circ Cardiovasc Interv ; 4(5): 495-504, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21953370

RESUMO

BACKGROUND: Sustained benefits of drug-eluting stents in femoropopliteal arteries have not been demonstrated. This prospective, multinational, randomized study was designed to compare the 12-month safety and effectiveness of a polymer-free, paclitaxel-coated nitinol drug-eluting stent (DES) with percutaneous transluminal angioplasty (PTA) and provisional bare metal stent (BMS) placement in patients with femoropopliteal peripheral artery disease. METHODS AND RESULTS: Patients were randomly assigned to primary DES implantation (n=236) or PTA (n=238). Demographics and lesion characteristics were similar between groups (eg, average lesion length, approximately 65±40 mm). One hundred twenty patients had acute PTA failure and underwent secondary random assignment to provisional DES (n=61) or BMS (n=59). Primary end points were the 12-month rates of event-free survival and patency in the primary DES and PTA groups. Compared with the PTA group, the primary DES group exhibited superior 12-month event-free survival (90.4% versus 82.6%; P=0.004) and primary patency (83.1% versus 32.8%; P<0.001), satisfying the primary hypotheses. In the secondary evaluations, (1) the primary DES group exhibited superior clinical benefit compared with the PTA group (88.3% versus 75.8%; P<0.001), (2) the provisional DES group exhibited superior primary patency (89.9% versus 73.0%; P=0.01) and superior clinical benefit (90.5% and 72.3%, P=0.009) compared with the provisional BMS group, and (3) the stent fracture rate (both DES and BMS) was 0.9% (4/457). CONCLUSIONS: Femoropopliteal peripheral artery disease treatment with the paclitaxel-eluting stent was associated with superior 12-month outcomes compared with PTA and provisional BMS placement.


Assuntos
Angioplastia com Balão , Stents Farmacológicos , Artéria Femoral/patologia , Doença Arterial Periférica/terapia , Artéria Poplítea/patologia , Idoso , Implante de Prótese Vascular , Intervalo Livre de Doença , Stents Farmacológicos/estatística & dados numéricos , Feminino , Artéria Femoral/metabolismo , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Paclitaxel/efeitos adversos , Doença Arterial Periférica/patologia , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/metabolismo , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
J Vasc Interv Radiol ; 22(5): 603-10, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21419649

RESUMO

PURPOSE: To evaluate the pharmacokinetics and safety of the Zilver PTX Drug-Eluting Stent (Cook Medical, Bloomington, Indiana) in a normal porcine artery model. MATERIALS AND METHODS: Pharmacokinetic analyses were performed using 18 pigs, each implanted with four paclitaxel-coated stents. Paclitaxel remaining on the stents, delivered locally (to artery wall), regionally (to adjacent and downstream muscle), and systemically (to plasma), was determined at various times through 56 days. For safety evaluation, local, regional, and systemic responses were grossly and histologically assessed at 1 month, 3 months, and 6 months in 21 additional pigs and compared with the responses to bare metal stents in 21 separate pigs. RESULTS: Stents delivered approximately 95% of the total paclitaxel within 24 hours after deployment. Nonetheless, there were sustained paclitaxel levels in the artery wall through 56 days, maintained at approximately 20% of the peak level through 14 days. Very little paclitaxel was distributed regionally or systemically, becoming undetectable in plasma at 10 hours. Complete necropsy, hematology, and serum chemistry revealed no adverse effects associated with the paclitaxel-coated stents. Within 3 months, vessels with both paclitaxel-coated and bare metal stents showed comparable, complete healing. CONCLUSIONS: The Zilver PTX stent appears to be safe, achieves sustained paclitaxel levels in the artery wall, and shows complete vessel healing comparable to bare metal stents within 3 months.


Assuntos
Artérias/efeitos dos fármacos , Fármacos Cardiovasculares/farmacocinética , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Paclitaxel/farmacocinética , Ligas , Animais , Artérias/metabolismo , Artérias/patologia , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/sangue , Stents Farmacológicos/efeitos adversos , Feminino , Masculino , Teste de Materiais , Modelos Animais , Paclitaxel/administração & dosagem , Paclitaxel/efeitos adversos , Paclitaxel/sangue , Desenho de Prótese , Medição de Risco , Sus scrofa , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...