Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Biomater ; 91: 135-143, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31004847

RESUMO

Elevated shear force caused by an anastomotic stenosis is a common complication at the blood vessel-vascular implant interface. Although elevated shear forces were found to cause platelet aggregation around a stenotic region, transient platelet exposure to elevated shear forces and subsequent downstream events occurring under lower shear force were not extensively studied. We hypothesize that effects of elevated shear forces on pre-activation of platelets for downstream adhesion and activation are relevant in understanding the increased thrombotic risk associated with blood-contacting devices. We designed a microfluidic flow system to mimic the hemodynamic environment of vasculature with an upstream anastomotic stenosis with five wall shear strain rates ranging from 1620 s-1 to 11560 s-1. Under shear flow conditions, transient exposure of whole blood to elevated shear forces resulted in higher downstream platelet adhesion onto three different immobilized platelet agonists: fibrinogen, collagen, or von Willebrand factor. Platelet expression of four activation markers (P-selectin, GPIIb/IIIa, lysosomal glycoprotein, and phosphatidylserine) significantly increased after transient exposure to higher upstream wall shear strain rates of 2975-11560 s-1. A significant lysis was observed when platelets were primed by upstream wall shear strain rate of 11560 s-1. These experimental results could be helpful to understand how altered hemodynamics around an anastomotic stenosis promotes thrombus formation downstream. STATEMENT OF SIGNIFICANCE: Studying the downstream response of platelets following transient exposure to an upstream agonist is important because of significant clinical implications to the implantation of vascular devices. Due to intimal fibrous hyperplasia, vascular biomaterials such as synthetic small-diameter vascular grafts sometimes become stenotic (narrow), leading to transient platelet exposure to elevated shear forces. In this study, a microfluidic flow system was developed to mimic a stenosed vascular graft and to investigate how highly elevated, transient upstream shear forces, typically found in severe stenosis, results in the pre-activation of platelets for downstream adhesion and activation. The findings of the present study have implications for optimizing the design of blood-contacting biomaterials in order to minimize thrombotic risk associated with transiently elevated shear forces. The findings also provide additional insights into the mechanisms of thrombus formation at the post-stenotic regions of vascular implants.


Assuntos
Plaquetas/metabolismo , Citometria de Fluxo , Modelos Cardiovasculares , Adesividade Plaquetária , Resistência ao Cisalhamento , Plaquetas/patologia , Constrição Patológica/metabolismo , Constrição Patológica/patologia , Humanos
2.
Acta Biomater ; 73: 228-235, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29654993

RESUMO

Platelets in flowing blood are sometimes exposed to elevated shear forces caused by anastomotic stenosis at the blood vessel-vascular implant interface. The objective of this study was to determine how effective upstream shear forces are in priming platelets for downstream adhesion and activation. Flow chambers with upstream stenotic regions (shear rates of 400-1000 s-1) were manufactured by relief molding of polydimethylsiloxane. Downstream from the stenotic regions, microcontact printing was used to covalently immobilize three different proteins (fibrinogen, collagen, or von Willebrand factor) to serve as platelet capture agents. Anticoagulated whole blood was perfused through the flow chambers and platelet adhesion to the downstream capture region was quantified. It was found that transient exposure of platelets to increased shear forces resulted in higher platelet adhesion on all three proteins. The duration of the platelet exposure to elevated shear forces was varied by changing the length of the stenotic regions. The results indicated that, in addition to the magnitude of shear forces, the duration of exposure to these forces was also an important factor in priming platelets. The effect of upstream shear forces on platelet activation was assessed by quantifying P-selectin, integrin αIIbß3, lysosomal glycoprotein, and phosphatidylserine exposure using flow cytometry. The results suggested that increased shear forces were capable of increasing the priming of platelets for downstream activation. This study implicates the anastomotic region(s) of vascular implants as a locus of platelet pre-activation that may lead to thrombus formation downstream. STATEMENT OF SIGNIFICANCE: A synthetic small-diameter vascular graft can often become stenotic due to intimal fibrous hyperplasia, either generally along the inside of the graft or at the anastomotic regions, leading to an increased shear force on flowing platelets. Our lab is studying how the upstream platelet preactivation (aka "priming") in flowing blood affects their downstream adhesion and activation. This manuscript describes a study in which priming of platelets is achieved by upstream stenotic narrowing in a microfluidic flow chamber. Such experimental design was intended to mimic a vascular implant with stenotic upstream anastomosis and downstream exposed platelet protein agonists. Understanding how the pre-activated platelets respond to imperfect vascular implant surfaces downstream is an important factor in designing better vascular implants.


Assuntos
Coagulação Sanguínea , Plaquetas/metabolismo , Citometria de Fluxo/instrumentação , Adesividade Plaquetária , Resistência ao Cisalhamento , Plaquetas/citologia , Citometria de Fluxo/métodos , Humanos
3.
J Biomater Sci Polym Ed ; 27(7): 692-708, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26878323

RESUMO

Guided tissue regeneration (GTR) is a widely used method in dental surgical procedures that utilizes a barrier membrane to exclude migration of epithelium and ensure repopulation of periodontal ligament cells at the sites having insufficient gingiva. Commercial GTR membranes are typically composed of synthetic polymers that have had mild clinical success mostly because of their lack of proper bioactivity and appropriate degradation profile. In this study, a natural polymer, aloe vera was blended with polycaprolactone (PCL) to create nanofibrous GTR membranes by electrospinning. Aloe vera has proven anti-inflammatory properties and enhances the regeneration of periodontium tissues. PCL, a synthetic polymer, is well known to produce miscible polyblends nanofibers with natural polymers. Nanofibrous membranes with varying composition of PCL to aloe vera were fabricated, and several physicochemical and biological properties, such as fiber morphology, wettability, chemical structure, mechanical strength, and cellular compatibility of the membranes were analyzed. PCL/aloe vera membranes with ratios from 100/00 to 70/30 showed good uniformity in fiber morphology and suitable mechanical properties, and retained the integrity of their fibrous structure in aqueous solutions. Experimental results, using cell viability assay and cell attachment observation, showed that the nanofibrous membranes support 3T3 cell viability and could be a potential candidate for GTR therapy.


Assuntos
Aloe/química , Materiais Biocompatíveis/química , Membranas Artificiais , Nanofibras/química , Nanotecnologia , Poliésteres/química , Células 3T3 , Animais , Materiais Biocompatíveis/farmacologia , Eletricidade , Regeneração Tecidual Guiada , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...