Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J R Soc Interface ; 21(214): 20240074, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38807524

RESUMO

The interaction among joints of the midtarsal complex and subtalar joint is important for locomotor function; however, its complexity poses substantial challenges in quantifying the joints' motions. We determine the mobility of these joints across locomotion tasks and investigate the influence of individual talus morphology on their motion. Using highly accurate biplanar videoradiography, three-dimensional bone kinematics were captured during walking, running and hopping. We calculated the axis of rotation of the midtarsal complex and subtalar joint for the landing and push-off phases. A comparison was made between these rotation axes and the morphological subtalar axis. Measurement included total rotation about and the orientation of the rotation axes in the direction of the subtalar joint and its deviation via spatial angles for both phases. The rotation axes of all three bones relative to the talus closely align with the morphological subtalar axis. This suggests that the midtarsal and subtalar joints' motions might be described by one commonly oriented axis. Despite having such an axis, the location of the axes and ranges of motion differed among the bones. Our results provide a novel perspective of healthy foot function across different sagittal plane-dominant locomotion tasks underscoring the importance of quantifying midtarsal complex and subtalar motion while accounting for an individual's talus morphology.


Assuntos
Corrida , Articulação Talocalcânea , Caminhada , Humanos , Masculino , Articulação Talocalcânea/fisiologia , Articulação Talocalcânea/anatomia & histologia , Fenômenos Biomecânicos , Corrida/fisiologia , Adulto , Caminhada/fisiologia , Feminino , Amplitude de Movimento Articular/fisiologia
2.
Proc Biol Sci ; 290(2009): 20231446, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37848066

RESUMO

Shoulder shape directly impacts forelimb function by contributing to glenohumeral (GH) range-of-motion (ROM). However, identifying traits that contribute most to ROM and visualizing how they do so remains challenging, ultimately limiting our ability to reconstruct function and behaviour in fossil species. To address these limitations, we developed an in silico proximity-driven model to simulate and visualize three-dimensional (3D) GH rotations in living primate species with diverse locomotor profiles, identify those shapes that are most predictive of ROM using geometric morphometrics, and apply subsequent insights to interpret function and behaviour in the fossil hominin Australopithecus sediba. We found that ROM metrics that incorporated 3D rotations best discriminated locomotor groups, and the magnitude of ROM (mobility) was decoupled from the anatomical location of ROM (e.g. high abduction versus low abduction). Morphological traits that enhanced mobility were decoupled from those that enabled overhead positions, and all non-human apes possessed the latter but not necessarily the former. Model simulation in A. sediba predicted high mobility and a ROM centred at lower abduction levels than in living apes but higher than in modern humans. Together these results identify novel form-to-function relationships in the shoulder and enhance visualization tools to reconstruct past function and behaviour.


Assuntos
Hominidae , Ombro , Animais , Ombro/anatomia & histologia , Hominidae/anatomia & histologia , Amplitude de Movimento Articular , Fósseis
3.
J Appl Biomech ; 39(6): 388-394, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37633654

RESUMO

It is not currently possible to directly and noninvasively measure in vivo patellofemoral joint contact force during dynamic movement; therefore, indirect methods are required. Simple models may be inaccurate because patellofemoral contact forces vary for the same knee flexion angle, and the patellofemoral joint has substantial out-of-plane motion. More sophisticated models use 3-dimensional kinematics and kinetics coupled to a subject-specific anatomical model to predict contact forces; however, these models are time consuming and expensive. We applied a principal component analysis prediction and regression method to predict patellofemoral joint contact forces derived from a robust musculoskeletal model using exclusively optical motion capture kinematics (external approach), and with both patellofemoral and optical motion capture kinematics (internal approach). We tested this on a heterogeneous population of asymptomatic subjects (n = 8) during ground-level walking (n = 12). We developed equations that successfully capture subject-specific gait characteristics with the internal approach outperforming the external. These approaches were compared with a knee-flexion based model in literature (Brechter model). Both outperformed the Brechter model in interquartile range, limits of agreement, and the coefficient of determination. The equations generated by these approaches are less computationally demanding than a musculoskeletal model and may act as an effective tool in future rapid gait analysis and biofeedback applications.


Assuntos
Articulação Patelofemoral , Humanos , Articulação do Joelho/cirurgia , Marcha , Caminhada , Fenômenos Biomecânicos
4.
Biol Rev Camb Philos Soc ; 98(6): 2136-2151, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37489055

RESUMO

In this narrative review we evaluate foundational biomechanical theories of human foot function in light of new data acquired with technology that was not available to early researchers. The formulation and perpetuation of early theories about foot function largely involved scientists who were medically trained with an interest in palaeoanthropology, driven by a desire to understand human foot pathologies. Early observations of people with flat feet and foot pain were analogized to those of our primate ancestors, with the concept of flat feet being a primitive trait, which was a driving influence in early foot biomechanics research. We describe the early emergence of the mobile adaptor-rigid lever theory, which was central to most biomechanical theories of human foot function. Many of these theories attempt to explain how a presumed stiffening behaviour of the foot enables forward propulsion. Interestingly, none of the subsequent theories have been able to explain how the foot stiffens for propulsion. Within this review we highlight the key omission that the mobile adaptor-rigid lever paradigm was never experimentally tested. We show based on current evidence that foot (quasi-)stiffness does not actually increase prior to, nor during propulsion. Based on current evidence, it is clear that the mechanical function of the foot is highly versatile. This function is adaptively controlled by the central nervous system to allow the foot to meet the wide variety of demands necessary for human locomotion. Importantly, it seems that substantial joint mobility is essential for this function. We suggest refraining from using simple, mechanical analogies to explain holistic foot function. We urge the scientific community to abandon the long-held mobile adaptor-rigid lever paradigm, and instead to acknowledge the versatile and non-linear mechanical behaviour of a foot that is adapted to meet constantly varying locomotory demands.


Assuntos
Pé Chato , Animais , Humanos , Pé/fisiologia , Fenômenos Biomecânicos/fisiologia , Locomoção
5.
Front Bioeng Biotechnol ; 11: 1155439, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324435

RESUMO

Developing the ability to habitually walk and run upright on two feet is one of the most significant transformations to have occurred in human evolution. Many musculoskeletal adaptations enabled bipedal locomotion, including dramatic structural changes to the foot and, in particular, the evolution of an elevated medial arch. The foot's arched structure has previously been assumed to play a central role in directly propelling the center of mass forward and upward through leverage about the toes and a spring-like energy recoil. However, it is unclear whether or how the plantarflexion mobility and height of the medial arch support its propulsive lever function. We use high-speed biplanar x-ray measurements of foot bone motion on seven participants while walking and running and compare their motion to a subject-specific model without arch recoil. We show that regardless of intraspecific differences in medial arch height, arch recoil enables a longer contact time and favorable propulsive conditions at the ankle for walking upright on an extended leg. The generally overlooked navicular-medial cuneiform joint is primarily responsible for arch recoil in human arches. The mechanism through which arch recoil enables an upright ankle posture may have helped drive the evolution of the longitudinal arch after our last common ancestor with chimpanzees, who lack arch plantarflexion mobility during push-off. Future morphological investigations of the navicular-medial cuneiform joint will likely provide new interpretations of the fossil record. Our work further suggests that enabling medial arch recoil in footwear and surgical interventions may be critical for maintaining the ankle's natural propulsive ability.

6.
J Vis Exp ; (183)2022 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-35635454

RESUMO

Measuring the motion of the small foot bones is critical for understanding pathological loss of function. Biplanar videoradiography is well-suited to measure in vivo bone motion, but challenges arise when estimating the rotation and translation (pose) of each bone. The bone's pose is typically estimated with marker- or model-based methods. Marker-based methods are highly accurate but uncommon in vivo due to their invasiveness. Model-based methods are more common but are currently less accurate as they rely on user input and lab-specific algorithms. This work presents a rare in vivo dataset of the calcaneus, talus, and tibia poses, as measured with marker-based methods during running and hopping. A method is included to train users to improve their initial guesses into model-based pose estimation software, using marker-based visual feedback. New operators were able to estimate bone poses within 2° of rotation and 1 mm of translation of the marker-based pose, similar to an expert user of the model-based software, and representing a substantial improvement over previously reported inter-operator variability. Further, this dataset can be used to validate other model-based pose estimation software. Ultimately, sharing this dataset will improve the speed and accuracy with which users can measure bone poses from biplanar videoradiography.


Assuntos
Algoritmos , Movimento , Extremidade Inferior , Rotação , Tíbia/diagnóstico por imagem
7.
JSES Int ; 6(1): 32-39, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35141673

RESUMO

BACKGROUND: To improve implant survival after reverse shoulder arthroplasty (RSA), surgeons need to maximize screw fixation. However, bone density variation and distribution within the scapula are not well understood as they relate to RSA. The three columns of bone in the scapula surrounding the glenoid fossa are the lateral border, the base of the coracoid process, and the spine of the scapula. In our previous study by Daalder et al on cadaveric specimens, the coracoid column was significantly less dense than the lateral border and spine. This study's objective was to verify whether these results are consistent with computer tomography (CT) scan information from patients undergoing RSA. METHODS: Two-dimensional axial CT images from twelve patients were segmented, and a three-dimensional digital model of the scapula was subsequently created using Mimics 17.0 Materialise Software (Leuven, Belgium). Hounsfield unit (HU) values representing cortical bone were filtered out to determine the distributions of trabecular bone density. An analysis of variance with post hoc Bonferroni tests determined the differences in bone density between the columns of bone in the scapula. RESULTS: The coracoid superolateral (270 ± 45.6 HU) to the suprascapular notch was significantly less dense than the inferior (356 ± 63.6 HU, P = .03, ds = 1.54) and anterosuperior portion of the lateral border (353 ± 68.9 HU, P = .04, ds = 1.42) and the posterior (368 ± 70 HU, P = .007, ds = 1.65) and anterior spine (370 ± 78.9 HU, P = .006, ds = 1.54). DISCUSSION/CONCLUSION: The higher-density bone in the spine and lateral border compared with the coracoid region may provide better bone purchase for screws when fixing the glenoid baseplate in RSA. This is in agreement with our previous study and indicates that the previous cadaveric results are applicable to clinical CT scan data. When these studies are taken together, they provide robust evidence for clinical applications, including having surgeons aim screws for higher-density regions to increase screw fixation, which may decrease micromotion and improve implant longevity.

8.
J Appl Biomech ; 38(1): 58-66, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35045394

RESUMO

Trochlear groove geometry and the location of the tibial tubercle, where the patellar tendon inserts, have both been associated with patellofemoral instability and can be modified surgically. Although their effects on patellofemoral biomechanics have been investigated individually, the interaction between the two is unclear. The authors' aim was to use statistical shape modeling and musculoskeletal simulation to examine the effect of patellofemoral geometry on the relationship between tibial tubercle location and patellofemoral function. A statistical shape model was used to generate new knee geometries with trochlear grooves ranging from shallow to deep. A Monte Carlo approach was used to create 750 knee models by randomly selecting a geometry and randomly translating the tibial tubercle medially/laterally and anteriorly. Each knee model was incorporated into a musculoskeletal model, and an overground walking trial was simulated. Knees with shallow trochlear geometry were more sensitive to tubercle medialization with greater changes in lateral patella position (-3.0 mm/cm medialization shallow vs -0.6 mm/cm deep) and cartilage contact pressure (-0.51 MPa/cm medialization shallow vs 0.04 MPa/cm deep). However, knees with deep trochlear geometry experienced greater increases in medial cartilage contact pressure with medialization. This modeling framework has the potential to aid in surgical decision making.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Fenômenos Biomecânicos , Humanos , Articulação do Joelho , Patela , Articulação Patelofemoral/cirurgia , Tíbia/cirurgia
9.
Comput Methods Biomech Biomed Engin ; 25(5): 554-565, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34698598

RESUMO

We developed and validated a multi-segment foot and ankle model for human walking and running. The model has 6-segments, and 7 degrees of freedom; motion between foot segments were constrained with a single oblique axis to enable triplanar motion [Joint Constrained (JC) model]. The accuracy of the JC model and that of a conventional model using a 6 degrees of freedom approach were assessed by comparison to segment motion determined with biplanar videoradiography. Compared to the 6-DoF model, our JC model demonstrated significantly smaller RMS differences [JC: 2.19° (1.43-2.73); 6-DoF: 3.25° (1.37-5.89)] across walking and running. The JC model is thus capable of more accurate musculoskeletal analyses and is also well suited for predictive simulations.


Assuntos
Tornozelo , Marcha , Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Fenômenos Biomecânicos , Humanos , Locomoção , Amplitude de Movimento Articular , Caminhada
10.
J Hand Surg Am ; 47(8): 762-771, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34627631

RESUMO

PURPOSE: To quantify the relative motion between the lunate and triquetrum during functional wrist movements and to examine the impact of wrist laxity on triquetral motion. METHODS: A digital database of wrist bone anatomy and carpal kinematics for 10 healthy volunteers in 10 different positions was used to study triquetral kinematics. The orientation of radiotriquetral (RT) and radiolunate rotation axes was compared during a variety of functional wrist movements, including radioulnar deviation (RUD) and flexion-extension (FE), and during a hammering task. The motion of the triquetrum relative to the radius during wrist RUD was compared with passive FE range of motion measurements (used as a surrogate measure for wrist laxity). RESULTS: The difference in the orientation of the radiolunate and RT rotation axes was less than 20° during most of the motions studied, except for radial deviation and for the first stage of the hammering task. During wrist RUD, the orientation of the RT rotation axis varied as a function of passive FE wrist range of motion. CONCLUSIONS: The suggestion that the lunate and triquetrum move together as an intercalated segment may be an oversimplification. We observed synchronous movement during some motions, but as the wrist entered RUD, the lunate and triquetrum no longer moved synchronously. These findings challenge the assumptions behind models describing the mechanical function of the carpals. CLINICAL RELEVANCE: Individual-specific differences in the amount of relative motion between the triquetrum and lunate may contribute to the variability in outcomes following lunotriquetral arthrodesis. Variation in triquetral motion patterns may also have an impact on the ability of the triquetrum to extend the lunate, affecting the development of carpal instability.


Assuntos
Ossos do Carpo , Instabilidade Articular , Osso Semilunar , Piramidal , Fenômenos Biomecânicos , Ossos do Carpo/diagnóstico por imagem , Humanos , Osso Semilunar/diagnóstico por imagem , Amplitude de Movimento Articular , Rotação , Piramidal/diagnóstico por imagem , Articulação do Punho/cirurgia
11.
Comput Methods Biomech Biomed Engin ; 25(8): 875-886, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34730046

RESUMO

A statistical shape model was created for a young adult population and used to predict tibia and fibula geometries from bony landmarks. Reconstruction errors with respect to CT data were quantified and compared to isometric scaling. Shape differences existed between sexes. The statistical shape model estimated tibia-fibula geometries from landmarks with high accuracy (RMSE = 1.51-1.62 mm), improving upon isometric scaling (RMSE = 1.78 mm). Reconstruction errors increased when the model was applied to older adults (RMSE = 2.11-2.17 mm). Improvements in geometric accuracy with shape model reconstruction changed hamstring moment arms 25-35% (1.0-1.3 mm) in young adults.


Assuntos
Fíbula , Tíbia , Idoso , Fíbula/diagnóstico por imagem , Humanos , Modelos Estatísticos , Caracteres Sexuais , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Adulto Jovem
12.
Biomechanics (Basel) ; 2(4): 494-499, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38249991

RESUMO

Much of our current understanding of age-related declines in mobility has been aided by decades of investigations on the role of muscle-tendon units spanning major lower extremity joints (e.g., hip, knee and ankle) for powering locomotion. Yet, mechanical contributions from foot structures are often neglected. This is despite the emerging evidence for their critical importance in youthful locomotion. With rapid growth in the field of human foot biomechanics over the last decade, our theoretical knowledge of young asymptomatic feet has transformed, from long-held views of a stiff lever and a shock-absorber to a versatile system that can modulate mechanical power and energy output to accommodate various locomotor task demands. In this perspective review, we predict that the next set of impactful discoveries related to locomotion in older adults will emerge by integrating the novel tools and approaches that are currently transforming the field of human foot biomechanics. By illuminating the functions of feet in older adults, we envision that future investigations will refine our mechanistic understanding of mobility deficits affecting our aging population, which may ultimately inspire targeted interventions to rejuvenate the mechanics and energetics of locomotion.

13.
J R Soc Interface ; 18(181): 20210326, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34404228

RESUMO

The patellofemoral joint plays a crucial mechanical role during walking and running. It increases the knee extensor mechanism's moment arm and reduces the knee extension muscle forces required to generate the extension moment that supports body weight, prevents knee buckling and propels the centre of mass. However, the mechanical implications of moment arm variation caused by patellofemoral and tibiofemoral motion remain unclear. We used a data-driven musculoskeletal model with a 12-degree-of-freedom knee to simulate the knee extension moment arm during walking and running. Using a geometric method to calculate the moment arm, we found smaller moment arms during running than during walking in the swing phase. Overall, knee flexion causes differences between running and walking moment arms as increased flexion causes a posterior shift in the tibiofemoral rotation axis and patella articulation with the distal femur. Moment arms were also affected by knee motion direction and best predicted by separating by direction instead of across the entire gait cycle. Furthermore, we found high inter-subject variation in the moment arm that was largely explained by out-of-plane motion. Our results are consistent with the concept that shorter moment arms increase the effective mechanical advantage of the knee and may contribute to increased running velocity.


Assuntos
Corrida , Caminhada , Braço , Fenômenos Biomecânicos , Marcha , Articulação do Joelho
14.
J Biomech Eng ; 143(8)2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34008841

RESUMO

The relationship between three-dimensional shape and patellofemoral mechanics is complicated. The Wiberg patella classification is a method of distinguishing shape differences in the axial plane of the patella that can be used to connect shape differences to observed mechanics. This study uses the Wiberg patella classification to differentiate variance in a statistical shape model describing changes in patella morphology and height. We investigate how patella morphology influences force distribution within the patellofemoral joint. The Wiberg type I patella has a more symmetrical medial and lateral facet while the type III patella has a larger lateral facet compared to medial. The second principal component of the statistical shape model described shape variation that qualitatively resembled the different Wiberg patellas. We generated patellofemoral morphologies from the statistical shape model and integrated them into a musculoskeletal model with a twelve degrees-of-freedom knee. We simulated an overground walking trial with these morphologies and recorded patellofemoral mechanics and ligament forces. An increase in patellar ligament force corresponded with an increase in patella height. Wiberg type III patellas had a sharper patella apex which related to lower ratios of quadriceps tendon forces to patellar ligament forces. The change in pivot point of the patella affects the ratio of forces as well as the patellofemoral reaction force. This study provides a better understanding of how patella morphology affects fundamental patella mechanics which may help identify at-risk populations for pathology development.


Assuntos
Ligamento Patelar
15.
Proc Biol Sci ; 288(1943): 20202095, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33468002

RESUMO

The arch of the human foot is unique among hominins as it is compliant at ground contact but sufficiently stiff to enable push-off. These behaviours are partly facilitated by the ligamentous plantar fascia whose role is central to two mechanisms. The ideal windlass mechanism assumes that the plantar fascia has a nearly constant length to directly couple toe dorsiflexion with a change in arch shape. However, the plantar fascia also stretches and then shortens throughout gait as the arch-spring stores and releases elastic energy. We aimed to understand how the extensible plantar fascia could behave as an ideal windlass when it has been shown to strain throughout gait, potentially compromising the one-to-one coupling between toe arc length and arch length. We measured foot bone motion and plantar fascia elongation using high-speed X-ray during running. We discovered that toe plantarflexion delays plantar fascia stretching at foot strike, which probably modifies the distribution of the load through other arch tissues. Through a pure windlass effect in propulsion, a quasi-isometric plantar fascia's shortening is delayed to later in stance. The plantar fascia then shortens concurrently to the windlass mechanism, likely enhancing arch recoil at push-off.


Assuntos
Fáscia , Corrida , Fenômenos Biomecânicos , , Marcha , Humanos
16.
Gait Posture ; 83: 174-176, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33152613

RESUMO

BACKGROUND: Instrumented treadmills facilitate analysis of consecutive strides in ways that typical overground gait data collections cannot. Researchers have quantified differences between joint kinetic measures whilst walking on an instrumented treadmill compared to those walking overground. The reason for such differences has not yet been established. RESEARCH QUESTION: Can we identify the source or sources of these errors by comparing centre of pressure and ground reaction force measurements recorded on a treadmill to those collected overground? METHODS: Kinematic and kinetic data were recorded while nineteen individuals walked continuously at their self-selected walking speed overground and on a treadmill. Comparisons of the centre of pressure and ground reaction forces were made between the two conditions using 2-tailed paired t-tests and Cohen's d effect size. RESULTS: The results indicated that participants had significantly faster backwards, lateral and medial centre of pressure velocities when walking on a treadmill compared to when they were walking overground. Additionally, participants also had significantly reduced peak propulsive ground reaction forces when walking on a treadmill than walking overground. SIGNIFICANCE: These results suggest that shear forces caused by the belts sliding over the treadmill force platforms affect the centre of pressure during early stance, and the minimal acceleration of a participant's centre of mass during treadmill walking results in reduced propulsive force during late stance. Therefore, care should be taken during studies when comparing kinetic gait variables between overground and treadmill walking.


Assuntos
Fenômenos Biomecânicos/fisiologia , Teste de Esforço/métodos , Marcha/fisiologia , Caminhada/fisiologia , Suporte de Carga/fisiologia , Feminino , Humanos , Masculino
17.
J Biomech ; 108: 109853, 2020 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-32636016

RESUMO

Human legs operate like springs with adjustable stiffness during locomotion, improving movement economy and versatility. The potential for the foot to contribute to this spring-like mechanism has been established. However, due to previous modelling approaches assuming a rigid-foot segment, it is unknown if ankle and foot quasi-stiffness can be actively regulated, quasi-stiffness being a measure of joint deformation under an applied load. In this study, we sought to determine if midfoot quasi-stiffness was increased in a similar manner as the ankle with increasing load demands, and if these changes were mediated by increased activation of the intrinsic foot muscles. We also quantified differences in measures of ankle joint quasi-stiffness attributable to the modelling assumption of a rigid-foot segment versus a multi-segment foot. Twenty-two healthy individuals performed a single-leg hopping task at three frequencies (2.0 Hz, 2.3 Hz, and 2.6 Hz) while measuring lower limb kinematics, kinetics and muscle activation (EMG). Kinetics and kinematics were calculated at the midfoot and using two different ankle models: rigid-foot model (shank-foot) and an anatomical ankle (shank-calcaneus). Midfoot quasi-stiffness increased with hopping-frequency (p < 0.05), while contact phase intrinsic foot muscle activation decreased (p < 0.05). The assumption of a rigid-foot model overestimated ankle ROM by ~10° and underestimated ankle quasi-stiffness by 45-60%. This study demonstrates that midfoot quasi-stiffness increases with hopping-frequency; however, the mechanism for these changes remains unclear. Furthermore, this study demonstrates the need to assess the ankle and foot independently, using appropriate models, to avoid significant inaccuracies in basic ankle kinematic and kinetic outputs, such as range of motion and joint quasi-stiffness.


Assuntos
Articulação do Tornozelo , Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Perna (Membro) , Amplitude de Movimento Articular
18.
Clin Biomech (Bristol, Avon) ; 78: 105091, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32580097

RESUMO

BACKGROUND: Numerous studies have reported an association between rotator cuff injury and two-dimensional measures of scapular morphology. However, the mechanical underpinnings explaining how these shape features affect glenohumeral joint function and lead to injury are poorly understood. We hypothesized that three-dimensional features of scapular morphology differentiate asymptomatic shoulders from those with rotator cuff tears, and that these features would alter the mechanical advantage of the supraspinatus. METHODS: Twenty-four individuals with supraspinatus tears and twenty-seven age-matched controls were recruited. A statistical shape analysis identified scapular features distinguishing symptomatic patients from asymptomatic controls. We examined the effect of injury-associated morphology on mechanics by developing a morphable model driven by six degree-of-freedom biplanar videoradiography data. We used the model to simulate abduction for a range of shapes and computed the supraspinatus moment arm. FINDINGS: Rotator cuff injury was associated with a cranial orientation of the glenoid and scapular spine (P = .011, d = 0.75) and/or decreased subacromial space (P = .001, d = 0.94). The shape analysis also identified previously undocumented features associated with superior inclination and subacromial narrowing. In our computational model, warping the scapula from a cranial to a lateral orientation increased the supraspinatus moment arm at 20° of abduction and decreased the moment arm at 160° of abduction. INTERPRETATIONS: Three-dimensional analysis of scapular morphology indicates a stronger relationship between morphology and cuff tears than two-dimensional measures. Insight into how morphological features affect rotator cuff mechanics may improve patient-specific strategies for prevention and treatment of cuff tears.


Assuntos
Fenômenos Mecânicos , Lesões do Manguito Rotador/patologia , Lesões do Manguito Rotador/fisiopatologia , Manguito Rotador/patologia , Manguito Rotador/fisiopatologia , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Articulação do Ombro/fisiopatologia
19.
Curr Rev Musculoskelet Med ; 13(3): 326-337, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32394363

RESUMO

PURPOSE OF REVIEW: The patellofemoral joint is a complicated articulation of the patella and femur that is prone to pathologies. The purpose of this review is to report on the current methods of investigating patellofemoral mechanics, factors that affect joint function, and future directions in patellofemoral joint research with emerging technologies and techniques. RECENT FINDINGS: While previous hypotheses have suggested that the patella is only a moment arm extender, recent literature has suggested that the patella influences the control of knee moments and forces acting on the tibia as well as contributes to various aspects of patellar function with minimal neural input. With advancements in simulating a six-degrees-of-freedom patellofemoral joint, we have gained a better understanding of patella motion and have shown that geometry and muscle activations impact patella mechanics. Research into influences on patella mechanics from other joints such as the hip and foot has become more prevalent. In this review, we report current in vivo, in vitro, and in silico approaches to studying the patellofemoral joint. Kinematic and anatomical factors that affect patellofemoral joint function such as patella alta and tilt or bone morphology and ligaments are discussed. Moving forward, we suggest that advanced in vivo dynamic imaging methods coupled to musculoskeletal simulation will provide further understanding of patellofemoral pathomechanics and allow engineers and clinicians to design interventions to mitigate or prevent patellofemoral pathologies.

20.
Artigo em Inglês | MEDLINE | ID: mdl-32211386

RESUMO

The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments using multi-segment foot models. Biplanar videoradiography and model-based scientific rotoscoping offers an exciting alternative that allows us to focus on the intricate motion of individual bones in the foot. However, scientific rotoscoping, the process of rotating and translating a 3D bone model so that it aligns with the captured x-ray images, is either semi- or completely manual and it is unknown how much human error affects tracking results. Thus, the aim of this study was to quantify the inter- and intra-operator reliability of manually rotoscoping in vivo bone motion of the tibia, talus, and calcaneus during running. Three-dimensional CT bone volumes and high-speed biplanar videoradiography images of the foot were acquired on six participants. The six-degree-of-freedom motions of the tibia, talus, and calcaneus were determined using a manual markerless registration algorithm. Two operators performed the tracking, and additionally, the first operator re-tracked all bones, to test for intra-operator effects. Mean RMS errors were 1.86 mm and 1.90° for intra-operator comparisons and 2.30 mm and 2.60° for inter-operator comparisons across all bones and planes. The moderate to strong similarity values indicate that tracking bones and joint kinematics between sessions and operators is reliable for running. These errors are likely acceptable for defining gross joint angles. However, this magnitude of error may limit the capacity to perform advanced analyses of joint interactions, particularly those that require precise (sub-millimeter) estimates of bone position and orientation. Optimizing the view and image quality of the biplanar videoradiography system as well as the automated tracking algorithms for rotoscoping bones in the foot are required to reduce these errors and the time burden associated with the manual processing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...