Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
Am J Ophthalmol ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218390

RESUMO

PURPOSE: To introduce and validate a novel substantially lower-priced and rapid swept-source investigational optical biometer in healthy and cataractous eyes, employing a thermally tuned laser diode used extensively in cell-phones and data communication as an alternative swept-source. DESIGN: Prospective accuracy, validity, and reliability analysis. METHODS: Sixty eyes of 59 subjects (twenty-nine eyes of 29 healthy subjects and thirty-one eyes of 30 cataract patients) were enrolled in a prospective comparative study at the Vienna General Hospital between August 2021 and April 2023. Averaged intraocular distances were acquired in 2.5 seconds from datasets consisting of 5000 consecutive A-scans at a single position by a low-cost swept-source optical biometry (SSOB) system. Instrument repeatability was assessed via standard deviations (SDs) and coefficients of variation (COVs) of parameters such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Healthy subjects and cataract patients were subsequently measured on the same day with the SSOB and a referential partial coherence interferometry (PCI) biometer (IOL Master 500, Zeiss, Jena, Germany) to establish AL inter-device correlation (r) for instrument calibration. AL and ACD as shared parameters between both biometers were evaluated for their limits of agreements (LoA) using Bland-Altman analysis. RESULTS: Repeated measurements of AL, ACD, LT, and CCT revealed SDs of 18 µm, 12 µm, 12 µm, and 10 µm, respectively. All parameters except for CCT had a COV < 1%. Except for 1 eye with white cataract, 59 eyes of 59 study participants with various degrees and types of cataract could be measured with both devices. AL inter-device correlation was excellent (r=>0.99). The 95 % LoAs between both biometers were -0.14 to 0.13 mm for AL and -0.28 to 0.25 mm for ACD. CONCLUSIONS: Optical biometry using a thermally-tunable VCSEL swept source light source has the potential to provide clinically relevant biometric parameters at an unprecedented 100-fold lower price point than currently employed state of the art optical biometers, paving the way for compact devices in remote care settings.

2.
Sensors (Basel) ; 24(16)2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39204856

RESUMO

Ocular aberrometry with a wide dynamic range for assessing vision performance and anterior segment imaging that provides anatomical details of the eye are both essential for vision research and clinical applications. Defocus error is a major limitation of digital wavefront aberrometry (DWA), as the blurring of the detected point spread function (PSF) significantly reduces the signal-to-noise ratio (SNR) beyond the ±3 D range. With the aid of Badal-like precompensation of defocus, the dynamic defocus range of the captured aberrated PSFs can be effectively extended. We demonstrate a dual-modality MHz VCSEL-based swept-source OCT (SS-OCT) system with easy switching between DWA and OCT imaging modes. The system is capable of measuring aberrations with defocus dynamic range of 20 D as well as providing fast anatomical imaging of the anterior segment at an A-scan rate of 1.6 MHz.

3.
Methods Enzymol ; 701: 1-46, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39025569

RESUMO

A widely known property of lipid membranes is their tendency to undergo a separation into disordered (Ld) and ordered (Lo) domains. This impacts the local structure of the membrane relevant for the physical (e.g., enhanced electroporation) and biological (e.g., protein sorting) significance of these regions. The increase in computing power, advancements in simulation software, and more detailed information about the composition of biological membranes shifts the study of these domains into the focus of classical molecular dynamics simulations. In this chapter, we present a versatile yet robust analysis pipeline that can be easily implemented and adapted for a wide range of lipid compositions. It employs Gaussian-based Hidden Markov Models to predict the hidden order states of individual lipids by describing their structure through the area per lipid and the average SCC order parameters per acyl chain. Regions of the membrane with a high correlation between ordered lipids are identified by employing the Getis-Ord local spatial autocorrelation statistic on a Voronoi tessellation of the lipids. As an example, the approach is applied to two distinct systems at a coarse-grained resolution, demonstrating either a strong tendency towards phase separation (1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-dilinoleoyl-sn-glycero-3-phosphocholine (DIPC), cholesterol) or a weak tendency toward phase separation (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC), 1-palmitoyl-2-docosahexaenoyl-sn-glycero-3-phosphocholine (PUPC), cholesterol). Explanations of the steps are complemented by coding examples written in Python, providing both a comprehensive understanding and practical guidance for a seamless integration of the workflow into individual projects.


Assuntos
Bicamadas Lipídicas , Simulação de Dinâmica Molecular , Bicamadas Lipídicas/química , Fosfatidilcolinas/química , Cadeias de Markov , Software , Lipídeos de Membrana/química , Microdomínios da Membrana/química , 1,2-Dipalmitoilfosfatidilcolina/química
4.
Transl Vis Sci Technol ; 13(4): 18, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607633

RESUMO

Purpose: To investigate the visualization capabilities of high-speed swept-source optical coherence tomography (SS-OCT) in cataract surgery. Methods: Cataract surgery was simulated in wet labs with ex vivo porcine eyes. Each phase of the surgery was visualized with a novel surgical microscope-integrated SS-OCT with a variable imaging speed of over 1 million A-scans per second. It was designed to provide four-dimensional (4D) live-volumetric videos, live B-scans, and volume capture scans. Results: Four-dimensional videos, B-scans, and volume capture scans of corneal incision, ophthalmic viscosurgical device injection, capsulorrhexis, phacoemulsification, intraocular lens (IOL) injection, and position of unfolded IOL in the capsular bag were recorded. The flexibility of the SS-OCT system allowed us to tailor the scanning parameters to meet the specific demands of dynamic surgical steps and static pauses. The entire length of the eye was recorded in a single scan, and unfolding of the IOL was visualized dynamically. Conclusions: The presented novel visualization method for fast ophthalmic surgical microscope-integrated intraoperative OCT imaging in cataract surgery allowed the visualization of all major steps of the procedure by achieving large imaging depths covering the entire eye and high acquisition speeds enabling live volumetric 4D-OCT imaging. This promising technology may become an integral part of routine and advanced robotic-assisted cataract surgery in the future. Translational Relevance: We demonstrate the visualization capabilities of a cutting edge swept-source OCT system integrated into an ophthalmic surgical microscope during cataract surgery.


Assuntos
Catarata , Lentes Intraoculares , Oftalmologia , Suínos , Animais , Tomografia de Coerência Óptica , Olho
5.
Nat Commun ; 15(1): 3521, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664456

RESUMO

Recently, a novel cyclo-heptapeptide composed of alternating D,L-amino acids and a unique thiazolidine heterocycle, called lugdunin, was discovered, which is produced by the nasal and skin commensal Staphylococcus lugdunensis. Lugdunin displays potent antimicrobial activity against a broad spectrum of Gram-positive bacteria, including challenging-to-treat methicillin-resistant Staphylococcus aureus (MRSA). Lugdunin specifically inhibits target bacteria by dissipating their membrane potential. However, the precise mode of action of this new class of fibupeptides remains largely elusive. Here, we disclose the mechanism by which lugdunin rapidly destabilizes the bacterial membrane potential using an in vitro approach. The peptide strongly partitions into lipid compositions resembling Gram-positive bacterial membranes but less in those harboring the eukaryotic membrane component cholesterol. Upon insertion, lugdunin forms hydrogen-bonded antiparallel ß-sheets by the formation of peptide nanotubes, as demonstrated by ATR-FTIR spectroscopy and molecular dynamics simulations. These hydrophilic nanotubes filled with a water wire facilitate not only the translocation of protons but also of monovalent cations as demonstrated by voltage-clamp experiments on black lipid membranes. Collectively, our results provide evidence that the natural fibupeptide lugdunin acts as a peptidic channel that is spontaneously formed by an intricate stacking mechanism, leading to the dissipation of a bacterial cell's membrane potential.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Simulação de Dinâmica Molecular , Água/química , Potenciais da Membrana/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Membrana Celular/química , Antibacterianos/farmacologia , Antibacterianos/química , Lipídeos de Membrana/química , Lipídeos de Membrana/metabolismo , Staphylococcus lugdunensis/efeitos dos fármacos , Staphylococcus lugdunensis/química , Staphylococcus lugdunensis/metabolismo , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacologia , Espectroscopia de Infravermelho com Transformada de Fourier , Testes de Sensibilidade Microbiana , Nanotubos/química , Peptídeos Antimicrobianos/química , Peptídeos Antimicrobianos/farmacologia
6.
Biomaterials ; 306: 122482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38301325

RESUMO

One of the hurdles to the development of new anticancer therapies is the lack of in vitro models which faithfully reproduce the in vivo tumor microenvironment (TME). Understanding the dynamic relationships between the components of the TME in a controllable, scalable, and reliable setting would indeed support the discovery of biological targets impacting cancer diagnosis and therapy. Cancer research is increasingly shifting from traditional two-dimensional (2D) cell culture toward three-dimensional (3D) culture models, which have been demonstrated to increase the significance and predictive value of in vitro data. In this scenario, microphysiological systems (also known as organs-on-chip) have emerged as a relevant technological platform enabling more predictive investigation of cell-cell and cell-ECM interplay in cancer, attracting a significant research effort in the last years. This review illustrates one decade of progress in the field of tumor-microenvironment-on-chip (TMOC) approaches, exploiting either cell-laden microfluidic chambers or microfluidic confined tumor spheroids to model the TME. TMOCs have been designed to recapitulate several aspects of the TME, including tumor cells, the tumor-associated stroma, the immune system, and the vascular component. Significantly, the last aspect has emerged for its pivotal role in orchestrating cellular interactions and modulating drug pharmacokinetics on-chip. A further advancement has been represented by integration of TMOCs into multi-organ microphysiological systems, with the final aim to follow the metastatic cascade to target organs and to study the effects of chemotherapies at a systemic level. We highlight that the increased degree of complexity achieved by the most advanced TMOC models has enabled scientists to shed new light on the role of microenvironmental factors in tumor progression, metastatic cascade, and response to drugs.


Assuntos
Neoplasias , Humanos , Neoplasias/patologia , Microfluídica , Microambiente Tumoral , Técnicas de Cultura de Células
7.
Acta Ophthalmol ; 102(5): e687-e695, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38126128

RESUMO

PURPOSE: To compare detection rates of microaneurysms (MAs) on high-speed megahertz optical coherence tomography angiography (MHz-OCTA), fluorescein angiography (FA) and colour fundus photography (CF) in patients with diabetic retinopathy (DR). METHODS: For this exploratory cross-sectional study, MHz-OCTA data were acquired with a swept-source OCT prototype (A-scan rate: 1.7 MHz), and FA and CF imaging was performed using Optos® California. MA count was manually evaluated on en face MHz-OCTA/FA/CF images within an extended ETDRS grid. Detectability of MAs visible on FA images was evaluated on corresponding MHz-OCTA and CF images. MA distribution and leakage were correlated with detectability on OCTA and CF imaging. RESULTS: 47 eyes with severe DR (n = 12) and proliferative DR (n = 35) were included. MHz-OCTA and CF imaging detected on average 56% and 36% of MAs, respectively. MHz-OCTA detection rate was significantly higher than CF (p < 0.01). The combination of MHz-OCTA and CF leads to an increased detection rate of 70%. There was no statistically significant association between leakage and MA detectability on OCTA (p = 0.13). For CF, the odds of detecting leaking MAs were significantly lower than non-leaking MAs (p = 0.012). Using MHz-OCTA, detection of MAs outside the ETDRS grid was less likely than MAs located within the ETDRS grid (outer ring, p < 0.01; inner ring, p = 0.028). No statistically significant difference between rings was observed for CF measurements. CONCLUSIONS: More MAs were detected on MHz-OCTA than on CF imaging. Detection rate was lower for MAs located outside the macular region with MHz-OCTA and for leaking MAs with CF imaging. Combining both non-invasive modalities can improve MA detection.


Assuntos
Retinopatia Diabética , Angiofluoresceinografia , Fundo de Olho , Microaneurisma , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Microaneurisma/diagnóstico , Microaneurisma/etiologia , Angiofluoresceinografia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Idoso
8.
Nat Commun ; 14(1): 8038, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081812

RESUMO

Biological membranes, composed mainly of phospholipids and cholesterol, play a vital role as cellular barriers. They undergo localized reshaping in response to environmental cues and protein interactions, with the energetics of deformations crucial for exerting biological functions. This study investigates the non-universal role of cholesterol on the structure and elasticity of saturated and unsaturated lipid membranes. Our study uncovers a highly cooperative relationship between thermal membrane bending and local cholesterol redistribution, with cholesterol showing a strong preference for the compressed membrane leaflet. Remarkably, in unsaturated membranes, increased cholesterol mobility enhances cooperativity, resulting in membrane softening despite membrane thickening and lipid compression caused by cholesterol. These findings elucidate the intricate interplay between thermodynamic forces and local molecular interactions that govern collective properties of membranes.


Assuntos
Colesterol , Fosfolipídeos , Membrana Celular/metabolismo , Fosfolipídeos/metabolismo , Membranas/metabolismo , Colesterol/metabolismo , Elasticidade , Bicamadas Lipídicas/química
9.
Biomed Opt Express ; 14(10): 5484-5487, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37854547

RESUMO

The guest editors introduce a feature issue commemorating the 30th anniversary of Optical Coherence Tomography.

10.
Eye Vis (Lond) ; 10(1): 30, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37525287

RESUMO

BACKGROUND: To comprehensively evaluate the agreement of component corneal aberrations from the newly updated wavefront analysis software of a swept-source optical coherence tomographer (SS-OCT) and a referential Placido-topography combined OCT device in elderly cataract patients. METHODS: Retrospective study including 103 eyes from 103 elderly patients scheduled for cataract surgery that were measured on the same day with a SS-OCT (Heidelberg Engineering, Germany) device and a Placido-topography combined OCT device (CSO, Italy). Anterior, total, and posterior corneal wavefront aberrations were evaluated for their mean differences and limits of agreement (LoA) via Bland-Altman plots. Vector analysis was additionally employed to compare corneal astigmatism measurements in dioptric vector space. RESULTS: Mean differences of all corneal aberrometric parameters did not exceed 0.05 µm. Total corneal aberrations were not significantly different from 0 except for vertical coma (- 0.04 µm; P = 0.003), spherical aberration (- 0.01 µm, P < 0.001), and root mean square (RMS) higher-order aberration (HOA) (0.03 µm, P = 0.04). The 95% LoA for total corneal aberration parameters between both devices were - 0.46 to 0.42 µm for horizontal astigmatism, - 0.37 to 0.41 µm for oblique astigmatism, - 0.19 to 0.17 µm for oblique trefoil, - 0.33 to 0.25 µm for vertical coma, - 0.20 to 0.22 µm for horizontal coma, - 0.22 to 0.20 µm for horizontal trefoil, - 0.11 to 0.08 µm for spherical aberration, and - 0.22 to 0.28 µm for RMS HOA. Vector analysis revealed no statistically significant mean differences for anterior, total, and posterior corneal astigmatism in dioptric vector space. CONCLUSION: In eyes undergoing cataract surgery with a regular elderly cornea, corneal wavefront analysis from the SS-OCT device showed functional equivalency to the reference device. Nevertheless, clinically relevant higher order aberration parameters should be interpreted with caution for surgical decision-making.

11.
Opt Lett ; 48(11): 3079-3082, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37262285

RESUMO

Swept-source optical coherence tomography (SS-OCT) demonstrates superior performance in comparison to spectral domain OCT with regard to depth ranging. The main driver of cost for SS-OCT systems is, however, the price of the source. Here we show a low-cost alternative swept source that uses a thermally tuned vertical-cavity surface-emitting laser (VCSEL) at 850 nm. Its center wavelength can be tuned by adjusting the operating temperature through modulation of the injection current. At 2 kHz sweep rate, the depth range of the system was 5 cm, with a sensitivity roll-off of under -3 dB across this range. The system achieved a sensitivity of 97 dB with a sample beam power of 0.3 mW and an axial resolution of 50 µm in air. To demonstrate the system performance in vivo, an eye of a healthy volunteer was measured, and full-eye scans were acquired at 25 and 50 kHz from the cornea to the retina. Based on our results, we believe that this technology can be used as a cost-effective alternative OCT for point-of-care diagnostics.

12.
Sci Rep ; 13(1): 8713, 2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-37248309

RESUMO

Diabetic retinopathy (DR), a pathologic change of the human retinal vasculature, is the leading cause of blindness in working-age adults with diabetes mellitus. Optical coherence tomography angiography (OCTA), a functional extension of optical coherence tomography, has shown potential as a tool for early diagnosis of DR through its ability to visualize the retinal vasculature in all spatial dimensions. Previously introduced deep learning-based classifiers were able to support the detection of DR in OCTA images, but require expert labeling at the pixel level, a labor-intensive and expensive process. We present a multiple instance learning-based network, MIL-ResNet,14 that is capable of detecting biomarkers in an OCTA dataset with high accuracy, without the need for annotations other than the information whether a scan is from a diabetic patient or not. The dataset we used for this study was acquired with a diagnostic ultra-widefield swept-source OCT device with a MHz A-scan rate. We were able to show that our proposed method outperforms previous state-of-the-art networks for this classification task, ResNet14 and VGG16. In addition, our network pays special attention to clinically relevant biomarkers and is robust against adversarial attacks. Therefore, we believe that it could serve as a powerful diagnostic decision support tool for clinical ophthalmic screening.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Adulto , Humanos , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Vasos Retinianos/patologia , Diagnóstico Precoce , Diabetes Mellitus/patologia
13.
bioRxiv ; 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37214871

RESUMO

The inhibitory Fcγ receptor FcγRIIb is involved in immune regulation and is known to localize to specific regions of the plasma membrane called lipid rafts. Previous studies suggested a link between the altered lateral receptor localization within the plasma membrane and the functional impairment of the FcγRIIb-I232T variant that is associated with systemic lupus erythematosus. Here, we conducted microsecond all-atom molecular dynamics simulations and IgG binding assays to investigate the lipid nano-environment of FcγRIIb monomers and of the FcγRIIb-I232T mutant within a plasma membrane model, the orientation of the FcγRIIb ectodomain, and its accessibility to IgG ligands. In contrast to previously proposed models, our simulations indicated that FcγRIIb does not favor a cholesterol- or a sphingolipid-enriched lipid environment. Interestingly, cholesterol was depleted for all studied FcγRIIb variants within a 2-3 nm environment of the receptor, counteracting the usage of raft terminology for models on receptor functionality. Instead, the receptor interacts with lipids that have poly-unsaturated fatty acyl chains and with (poly-) anionic lipids within the cytosolic membrane leaflet. We also found that FcγRIIb monomers adopt a conformation that is not suitable for binding to its IgG ligand, consistent with a lack of detectable binding of monomeric IgG in experiments on primary immune cells. However, our results propose that multivalent IgG complexes might stabilize FcγRIIb in a binding-competent conformation. We suggest differences in receptor complex formation within the membrane as a plausible cause of the altered membrane localization or clustering and the altered suppressive function of the FcγRIIb-I232T variant.

14.
Nat Commun ; 14(1): 2123, 2023 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-37055412

RESUMO

Redox signaling and cardiac function are tightly linked. However, it is largely unknown which protein targets are affected by hydrogen peroxide (H2O2) in cardiomyocytes that underly impaired inotropic effects during oxidative stress. Here, we combine a chemogenetic mouse model (HyPer-DAO mice) and a redox-proteomics approach to identify redox sensitive proteins. Using the HyPer-DAO mice, we demonstrate that increased endogenous production of H2O2 in cardiomyocytes leads to a reversible impairment of cardiac contractility in vivo. Notably, we identify the γ-subunit of the TCA cycle enzyme isocitrate dehydrogenase (IDH)3 as a redox switch, linking its modification to altered mitochondrial metabolism. Using microsecond molecular dynamics simulations and experiments using cysteine-gene-edited cells reveal that IDH3γ Cys148 and 284 are critically involved in the H2O2-dependent regulation of IDH3 activity. Our findings provide an unexpected mechanism by which mitochondrial metabolism can be modulated through redox signaling processes.


Assuntos
Peróxido de Hidrogênio , Mitocôndrias , Camundongos , Animais , Peróxido de Hidrogênio/metabolismo , Mitocôndrias/metabolismo , Oxirredução , Metabolismo Energético , Miócitos Cardíacos/metabolismo , Estresse Oxidativo
15.
Sci Rep ; 13(1): 5760, 2023 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-37031338

RESUMO

By providing three-dimensional visualization of tissues and instruments at high resolution, live volumetric optical coherence tomography (4D-OCT) has the potential to revolutionize ophthalmic surgery. However, the necessary imaging speed is accompanied by increased noise levels. A high data rate and the requirement for minimal latency impose major limitations for real-time noise reduction. In this work, we propose a low complexity neural network for denoising, directly incorporated into the image reconstruction pipeline of a microscope-integrated 4D-OCT prototype with an A-scan rate of 1.2 MHz. For this purpose, we trained a blind-spot network on unpaired OCT images using a self-supervised learning approach. With an optimized U-Net, only a few milliseconds of additional latency were introduced. Simultaneously, these architectural adaptations improved the numerical denoising performance compared to the basic setup, outperforming non-local filtering algorithms. Layers and edges of anatomical structures in B-scans were better preserved than with Gaussian filtering despite comparable processing time. By comparing scenes with and without denoising employed, we show that neural networks can be used to improve visual appearance of volumetric renderings in real time. Enhancing the rendering quality is an important step for the clinical acceptance and translation of 4D-OCT as an intra-surgical guidance tool.


Assuntos
Aprendizado Profundo , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Tomografia de Coerência Óptica/métodos , Razão Sinal-Ruído
16.
Front Oncol ; 13: 1105648, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36890834

RESUMO

Purpose: Modern techniques for improved tumor visualization have the aim to maximize the extent of resection during brain tumor surgery and thus improve patient prognosis. Optical imaging of autofluorescence is a powerful and non-invasive tool to monitor metabolic changes and transformation in brain tumors. Cellular redox ratios can be retrieved from fluorescence emitted by the coenzymes reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H) and flavin adenine dinucleotide (FAD). Recent studies point out that the influence of flavin mononucleotide (FMN) has been underestimated. Experimental design: Fluorescence lifetime imaging and fluorescence spectroscopy were performed through a modified surgical microscope. We acquired 361 flavin fluorescence lifetime (500-580 nm) and fluorescence spectra (430-740 nm) data points on freshly excised different brain tumors: low-grade gliomas (N=17), high-grade gliomas (N=42), meningiomas (N=23), metastases (N=26) and specimens from the non-tumorous brain (N=3). Results: Protein-bound FMN fluorescence in brain tumors did increase with a shift toward a more glycolytic metabolism (R=-0.87). This increased the average flavin fluorescence lifetime in tumor entities with respect to the non-tumorous brain. Further, these metrics were characteristic for the different tumor entities and showed promise for machine learning based brain tumor classification. Conclusions: Our results shed light on FMN fluorescence in metabolic imaging and outline the potential for supporting the neurosurgeon in visualizing and classifying brain tumor tissue during surgery.

17.
J Chem Theory Comput ; 19(6): 1908-1921, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36895066

RESUMO

Simulations of lipid membranes typically make use of periodic boundary conditions to mimic macroscopically sized membranes and allow for comparison to experiments performed e.g. on planar lipid membranes or on unilamellar lipid vesicles. However, the lateral periodicity partly suppresses membrane fluctuations or membrane remodeling, processes that are of particular importance in the study of asymmetric membranes-i.e. membranes with integral or associated proteins and/or asymmetric lipid compositions. Here, we devised a simple albeit powerful lipid bicelle model system that (i) displays similar structural, dynamical, and mechanical properties compared to infinite periodic lipid membrane systems and allows (ii) for the study of asymmetric lipid bilayer systems and (iii) the unperturbed formation of local spontaneous curvature induced by lipids or proteins in molecular dynamics simulations. In addition, the system is characterized by largely unbiased thermal fluctuations as opposed to standard bilayer systems. Application of the bicelle system for an asymmetric lipid composition resembling the plasma membrane reveals that the cholesterol density for a tension-free plasma membrane with a vanishing spontaneous curvature is larger by 28% within the extracellular leaflet compared to the cytosolic leaflet.


Assuntos
Bicamadas Lipídicas , Simulação de Dinâmica Molecular , Bicamadas Lipídicas/química , Membrana Celular/química , Lipossomas Unilamelares , Modelos Biológicos
18.
Biomed Opt Express ; 14(2): 846-865, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874504

RESUMO

Intraoperative optical coherence tomography is still not overly pervasive in routine ophthalmic surgery, despite evident clinical benefits. That is because today's spectral-domain optical coherence tomography systems lack flexibility, acquisition speed, and imaging depth. We present to the best of our knowledge the most flexible swept-source optical coherence tomography (SS-OCT) engine coupled to an ophthalmic surgical microscope that operates at MHz A-scan rates. We use a MEMS tunable VCSEL to implement application-specific imaging modes, enabling diagnostic and documentary capture scans, live B-scan visualizations, and real-time 4D-OCT renderings. The technical design and implementation of the SS-OCT engine, as well as the reconstruction and rendering platform, are presented. All imaging modes are evaluated in surgical mock maneuvers using ex vivo bovine and porcine eye models. The applicability and limitations of MHz SS-OCT as a visualization tool for ophthalmic surgery are discussed.

19.
Immunity ; 56(5): 1046-1063.e7, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-36948194

RESUMO

Immunoglobulin G (IgG) antibodies are major drivers of inflammation during infectious and autoimmune diseases. In pooled serum IgG (IVIg), however, antibodies have a potent immunomodulatory and anti-inflammatory activity, but how this is mediated is unclear. We studied IgG-dependent initiation of resolution of inflammation in cytokine- and autoantibody-driven models of rheumatoid arthritis and found IVIg sialylation inhibited joint inflammation, whereas inhibition of osteoclastogenesis was sialic acid independent. Instead, IVIg-dependent inhibition of osteoclastogenesis was abrogated in mice lacking receptors Dectin-1 or FcγRIIb. Atomistic molecular dynamics simulations and super-resolution microscopy revealed that Dectin-1 promoted FcγRIIb membrane conformations that allowed productive IgG binding and enhanced interactions with mouse and human IgG subclasses. IVIg reprogrammed monocytes via FcγRIIb-dependent signaling that required Dectin-1. Our data identify a pathogen-independent function of Dectin-1 as a co-inhibitory checkpoint for IgG-dependent inhibition of mouse and human osteoclastogenesis. These findings may have implications for therapeutic targeting of autoantibody and cytokine-driven inflammation.


Assuntos
Artrite Reumatoide , Imunoglobulinas Intravenosas , Lectinas Tipo C , Receptores de IgG , Animais , Humanos , Camundongos , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/imunologia , Membrana Celular/metabolismo , Imunoglobulinas Intravenosas/administração & dosagem , Lectinas Tipo C/metabolismo , Camundongos Endogâmicos C57BL , Osteoclastos/metabolismo , Processamento de Proteína Pós-Traducional , Receptores de IgG/metabolismo
20.
Biofabrication ; 15(2)2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36689776

RESUMO

Three-dimensional (3D) bioprinting is an emerging technology, which turned out to be an optimal tool for tissue engineering approaches. To date, different printing systems have been developed. Among them, the extrusion-based approach demonstrated to be the most suitable for skeletal muscle tissue engineering, due to its ability to produce and deposit printing fibers in a parallel pattern that well mimic the native skeletal muscle tissue architecture. In tissue bioengineering, a key role is played by biomaterials, which must possess the key requisite of 'printability'. Nevertheless, this feature is not often well correlated with cell requirements, such as motives for cellular adhesion and/or absorbability. To overcome this hurdle, several efforts have been made to obtain an effective bioink by combining two different biomaterials in order to reach a good printability besides a suitable biological activity. However, despite being efficient, this strategy reveals several outcomes limitations. We report here the development and characterization of a novel extrusion-based 3D bioprinting system, and its application for correction of volumetric muscle loss (VML) injury in a mouse model. The developed bioprinting system is based on the use of PEG-Fibrinogen, a unique biomaterial with excellent biocompatibility, well-suited for skeletal muscle tissue engineering. With this approach, we obtained highly organized 3D constructs, in which murine muscle progenitors were able to differentiate into muscle fibers arranged in aligned bundles and capable of spontaneously contracting when culturedin vitro. Furthermore, to evaluate the potential of the developed system in future regenerative medicine applications, bioprinted constructs laden with either murine or human muscle progenitors were transplanted to regenerate theTibialis Anteriormuscle of a VML murine model, one month after grafting.


Assuntos
Bioimpressão , Engenharia Tecidual , Camundongos , Humanos , Animais , Engenharia Tecidual/métodos , Alicerces Teciduais , Bioimpressão/métodos , Impressão Tridimensional , Músculo Esquelético , Materiais Biocompatíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA