1.
Anaesthesia ; 65(6): 595-600, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20412149

RESUMO

We enrolled 114 patients, aged 65-83 years, undergoing elective surgery (duration > 2h) into a randomised, controlled study to evaluate the performance of bispectral index and spectral entropy for monitoring depth of xenon versus propofol anaesthesia. In the propofol group, bispectral index and state entropy values were comparable. In the xenon group, bispectral index values resembled those in the propofol group, but spectral entropy levels were significantly lower. Mean arterial blood pressure was higher and heart rate was lower in the xenon group than in the propofol group. Bispectral index and spectral entropy considerably diverged during xenon but not during propofol anaesthesia. We therefore conclude that these measures are not interchangeable for the assessment of depth of hypnosis and that bispectral index is likely to reflect actual depth of anaesthesia more precisely compared with spectral entropy.


Assuntos
Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Eletroencefalografia/efeitos dos fármacos , Propofol/farmacologia , Xenônio/farmacologia , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea/efeitos dos fármacos , Entropia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS