Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Asthma Allergy ; 14: 381-392, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33907423

RESUMO

BACKGROUND: Tezepelumab is an anti-thymic stromal lymphopoietin monoclonal antibody in development for the treatment of severe asthma. This study assessed the functionality and performance of an accessorized pre-filled syringe (APFS) and an autoinjector (AI) for administration of tezepelumab in the clinic and at home. METHODS: This phase 3, multicenter, randomized, open-label, parallel-group study (PATH-HOME, ClinicalTrials.gov identifier: NCT03968978) was conducted in patients aged 12-80 years with asthma that was uncontrolled despite treatment with medium- to high-dose inhaled corticosteroids plus at least one additional controller medication. Patients received six subcutaneous doses of tezepelumab 210 mg via APFS or AI. The first dose was administered by a healthcare professional, and patients or caregivers administered subsequent doses. First, second, third and final doses were administered in the clinic; fourth and fifth doses were administered at home. The primary endpoint was the proportion of successful administrations of tezepelumab. Secondary endpoints included the functionality and performance of the devices, Asthma Control Questionnaire (ACQ)-6 score, pharmacokinetics and safety. RESULTS: Overall, 216 patients were randomized (APFS, n=111; AI, n=105). Tezepelumab was successfully administered via APFS by 91.7% of the participants (100/109) and via AI by 92.4% (97/105). Overall, 95.4-97.1% of at-home administrations were successful across device groups. Malfunction occurred in 6 of 655 dispensed APFSs and 5 of 624 dispensed AIs. Clinically meaningful improvements in ACQ-6 score were observed after 24 weeks in 81.1% and 76.2% of the patients in the APFS and AI groups, respectively. Tezepelumab pharmacokinetics were consistent between device groups and with previous studies. The most common adverse event was nasopharyngitis (9.3%). Injection-site reactions occurred in 5.7% and 0% of the patients in the AI and APFS groups, respectively. CONCLUSION: This study demonstrated that the APFS and AI were functional and reliable, and performed equally well at home and in the clinic.

2.
Phys Chem Chem Phys ; 22(38): 21977-21987, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-32975272

RESUMO

Coin cells are used extensively as test devices in battery research for evaluation of new materials and optimization of cycling protocols. In this study, in situ X-ray diffraction profilometry is used to characterize spatial distribution of the active materials, lithiation, and phase distribution in electrodes of NCM523/graphite coin cells. The X-ray data indicate uneven areal compression of the electrode assembly in such cells, which we trace to a specific design feature that leads to elastic deformation of a metal spacer. Steep lithiation gradients observed in the electrodes imply radially-dependent resistivity, for which uneven compression of the separator is a likely cause. Electrochemical model calculations suggest that variable porosity of the polymer separator would account for the salient features of spatial profiles observed in these coin cells.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...