Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vaccines (Basel) ; 12(2)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38400096

RESUMO

Autologous dendritic cell (DC)-based immunotherapy is a cell-based advanced therapy medicinal product (ATMP) that was first introduced more than three decades ago. In the current study, our objective was to establish a harmonized protocol using two varied antigenic sources and a good manufacturing practice (GMP)-compliant, manual method for generating clinical-grade DCs at a limited-resource academic setting. After obtaining ethical committee-approved informed consent, the recruited patients underwent leukapheresis, and single-batch DC production was carried out. Using responder-independent flow cytometric assays as quality control (QC) criteria, we propose a differentiation and maturation index (DI and MI, respectively), calculated with the QC cut-off and actual scores of each batch for comparison. Changes during cryopreservation and personnel variation were assessed periodically for up to two to three years. Using our harmonized batch production protocol, the average DI was 1.39 and MI was 1.25. Allogenic responder proliferation was observed in all patients, while IFN-gamma secretion, evaluated using flow cytometry, was detected in 10/36 patients and significantly correlated with CD8+ T cell proliferation (p value-0.0002). Tracking the viability and phenotype of cryopreserved MDCs showed a >90% viability for up to three years, while a mature DC phenotype was retained for up to one year. Our results confirm that the manual/semi-automated protocol was simple, consistent, and cost-effective, without the requirement for expensive equipment and without compromising on the quality of the final product.

2.
Ann Clin Biochem ; 60(5): 339-348, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37158306

RESUMO

BACKGROUND: Several studies have demonstrated the analytical sensitivity of MALDI-TOF mass spectrometry (MALDI-TOF MS) by immunoenrichment for M-protein analysis. We report the results of a novel, low-cost, reagent-based extraction process using acetonitrile (ACN) precipitation to enrich for κ and λ light chains which can be analysed by MALDI-TOF MS. METHODS: Institutional Ethics committee approval was obtained. Serum samples from patients with monoclonal gammopathy of undetermined significance (MGUS), multiple myeloma (MM), plasmacytoma, AL amyloidosis and Waldenström macroglobulinemia (WM) underwent ACN precipitation. The images obtained were overlaid on apparently healthy donor serum samples to confirm the presence of M-protein. A sample was considered positive for M-protein if there was a sharp or broad peak within the κ or λ mass/charge (m/z) range: m/z- [M + 2H]2+: 11,550-12,300 Da and λ m/z- [M + 2H]2+: 11,100-11,500 Da. Images were acquired at a m/z range of 10,000-29,000 Da. Corresponding serum protein electrophoresis (SPEP), serum immunofixation electrophoresis (IFE) and serum free light chain (sFLC) assay by nephelometry were performed for all the samples. RESULTS: Two-hundred-and-two serum samples were included in the study: MM- 184 (91%); AL amyloidosis- 2 (1%); plasmacytoma- 8 (4%); MGUS- 6 (3%) and WM- 2 (1%). All the SPEP positive samples were identified by MALDI-TOF MS. Out of 179 samples positive for M-protein by IFE, MALDI-TOF MS was positive in 176 samples (98%). Compared to IFE, the sensitivity and specificity of M-protein identification by MALDI-TOF MS were 98.3% and 52.2%, respectively. CONCLUSIONS: This study demonstrates the feasibility of qualitatively identifying M-protein without the need for antibody-based immunoenrichment, making the technique cost-effective.


Assuntos
Amiloidose de Cadeia Leve de Imunoglobulina , Mieloma Múltiplo , Paraproteinemias , Plasmocitoma , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cadeias Leves de Imunoglobulina , Acetonitrilas , Paraproteinemias/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...