Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 191: 110519, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36327614

RESUMO

While measuring the relative gamma-to-electron conversion efficiencies of nanoparticles by incorporating them into plastic scintillator and comparing the number of counts in pulse height spectrum for gamma-rays from 241Am, WO3, and PbO nanocomposites offered lesser scintillation counts than their unloaded counterparts. As investigated, these nanoparticles absorb a major portion of outgoing electron energy such that exiting electrons turn incapable of scintillating the medium. This observation hints why only selected species of nanoparticles successfully enhance the gamma-counting efficiency of plastic scintillators.


Assuntos
Nanocompostos , Nanopartículas , Contagem de Cintilação , Plásticos , Elétrons
2.
Nanotechnology ; 32(50)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34517349

RESUMO

Flexible strain sensors are emerging rapidly and overcoming the drawbacks of traditional strain sensors. However, many flexible sensors failed to balance the sensitivity, response time, and the desired sensing range. This work proposes a novel and cost-effective strain sensor which simultaneously achieved high sensitivity, fast response, and a good sensing range. It illustrates a prototype strain sensor realized with a nanocomposite constituting reduced graphene oxide and palladium as the primary sensing elements. These sensors were fabricated with manual screen-printing technology. The sensor exhibited an outstanding performance for the different strains ranging from 0.1% to 45%. As a result, a substantially high gauge factor around 1523 at a strain of as high as 45% and a rapid response time of 47 ms was obtained. This work demonstrated potential applications like real-time monitoring of pulse and respiration, and other physical movement detection, which become crucial parameters to be measured continuously during the COVID-19 pandemic.

3.
Nanotechnology ; 31(3): 035501, 2020 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-31557751

RESUMO

We report a novel strain sensor based on reduced graphene oxide (rGO) with palladium (Pd) nano-composite. The sensor was fabricated on the SS304 stainless-steel substrate using a screen-printing method. Graphene oxide was synthesized using a modified Hummer's method and reduced using a chemical route. Field emission-scanning electron microscope, x-ray diffraction and Raman spectroscopy were used to characterize the as-synthesized nano-composite. The as-fabricated strain sensor was tested for tensile strain using Micro-universal Test Machine and the change in resistance for different strains was recorded. The sensor response was observed to be stable and linear within the applied strain range of 0-3000 microstrains, and an average gauge factor of 42.69 was obtained in this range.

4.
Nanotechnology ; 30(47): 475502, 2019 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-31430732

RESUMO

This paper presents development and performance assessment of an innovative and a highly potent graphene-electrolyte capacitive sensor (GECS) based on the supercapacitor model. Although graphene has been widely researched and adapted in supercapacitors as electrode material, this combination has not been applied in sensor technology. A low base capacitance, generally the impeding factor in capacitive sensors, is addressed by incorporating electric double layer capacitance in GECS, and a million-fold increase in base capacitance is achieved. The high base capacitance (∼22.0 µF) promises to solve many inherent issues pertaining to capacitive sensors. GECS is fabricated by using thermally reduced microwave exfoliated graphene oxide material to form interdigitated electrodes coated with solid-state electrolyte which forms the double layer capacitance. The capacitance response of GECS on subjecting to strain is examined and an enormous operating range (∼300 nF) is seen, which is the salient feature of this sensor. The GECS showed an impressive device sensitivity of 11.24 nF kPa-1 and good immunity towards noise i.e. lead capacitance and stray capacitance. Two regimes of operation are identified based on the procedure of device fabrication. The device can be applied to varied applications and one such biomedical application of breath pattern monitoring is demonstrated.


Assuntos
Tecnologia Biomédica/instrumentação , Capacitância Elétrica , Eletrólitos/química , Grafite/química , Simulação por Computador , Micro-Ondas , Nanopartículas/química , Oxirredução , Análise Espectral Raman , Difração de Raios X
5.
Small ; : e1800608, 2018 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-29939479

RESUMO

Crash sensing and its assessment play a pivotal role in autonomous vehicles for preventing fatal casualties. Existing crash sensors are severely bottlenecked by sluggish response time, rigid mechanical components, and space constraints. Miniaturized sensors embedded with custom-tailored nanomaterials upholds potential to overcome these limitations. In this article, piezoelectric Zinc-Oxide thin film as a crash sensing layer is integrated onto a flexible metal-alloy cantilever. Material characterization studies are conducted to confirm piezoelectric property of sputtered ZnO film. The piezoelectric d 31 coefficient value of ZnO film was 7.2 pm V-1 . The ZnO sensing element is firmly mounted on a scaled car model and used in a crash sensing experimental set-up. A comprehensive theoretical analysis for two different real scenarios (nearly elastic and nearly inelastic collision) of crash events followed by experimental study is discussed. The crash sensor's output exhibits a linear relationship with magnitude of impact forces experienced at crash events. The response time of ZnO crash sensor is 18.2 ms, and it exhibits a sensitivity of 28.7 mV N-1 . The developed crash sensor has potential to replace bulk material sensors owing to its faster response time, high sensitivity, and compactness as the demand for crash sensors in next-generation automobile industries is progressively growing.

6.
Rev Sci Instrum ; 88(1): 015102, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147679

RESUMO

Micropump technology has evolved significantly in the last two decades and is finding a variety of applications ranging from µTAS (micro Total Analysis System) to drug delivery. However, the application area of the micropump is limited owing to: simple pumping mechanism, ease of handling, controlled (microliter to milliliter) delivery, continuous delivery, and accuracy in flow rate. Here, the author presents the design, development, characterization, and precision flow controlling of a DC-motor driven peristaltic pump for controlled drug delivery application. All the micropump components were fabricated using the conventional fabrication technique. The volume flow variation of the pump has been characterized for different viscous fluids. The change in volume flow due to change in back pressure has been presented in detail. The fail-safe mode operation of the pump has been tested and leak rate was measured (∼0.14% leak for an inlet pressure of 140 kPa) for different inlet pressures. The precision volume flow of the pump has been achieved by measuring the pinch cam position and load current. The accuracy in the volume flow has been measured after 300 rotations. Finally, the complete system has been integrated with the necessary electronics and an android application has been developed for the self-administration of bolus and basal delivery of insulin.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Bombas de Infusão , Microfluídica , Sistemas de Liberação de Medicamentos/métodos , Desenho de Equipamento
7.
Rev Sci Instrum ; 86(11): 115113, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628178

RESUMO

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory.

8.
Am J Otolaryngol ; 36(2): 122-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25447932

RESUMO

OBJECTIVE: The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). METHODS: PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. RESULTS: In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14±5.87% and 48.85±5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33±10.54% and LN: 32.24±11.54%). Moderate correlation was observed in healthy group (r=-0.710, p<0.001 for RN and r=-0.651, p<0.001 for LN), and moderate to strong correlation in patient group (r=-0.751, p<0.01 for RN and r=-0.885, p<0.0001 for LN). CONCLUSION: PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice.


Assuntos
Técnicas de Diagnóstico do Sistema Respiratório/instrumentação , Obstrução Nasal/diagnóstico , Polivinil , Rinomanometria/instrumentação , Rinomanometria/métodos , Adulto , Análise de Variância , Estudos de Casos e Controles , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cavidade Nasal/fisiopatologia , Obstrução Nasal/fisiopatologia , Valores de Referência , Transdutores , Escala Visual Analógica
9.
J Nanosci Nanotechnol ; 14(7): 5485-90, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24758054

RESUMO

Self catalytic growth of Indium Oxide (In2O3) nanowires (NWs) have been grown by resistive thermal evaporation of Indium (In) in the presence of oxygen without use of any additional metal catalyst. Nanowires growth took place at low substrate temperature of 370-420 degrees C at an applied current of 180-200 A to the evaporation boat. Morphology, microstructures, and compositional studies of the grown nanowires were performed by employing field emission scanning electron microscopy (FESEM), X-Ray diffraction (XRD), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) respectively. Nanowires were uniformly grown over the entire Si substrate and each of the nanowire is capped with a catalyst particle at their end. X-ray diffraction study reveals the crystalline nature of the grown nanowires. Transmission electron microscopy study on the nanowires further confirmed the single crystalline nature of the nanowires. Energy dispersive X-ray analysis on the nanowires and capped nanoparticle confirmed that Indium act as catalyst for In2O3 nanowires growth. A self catalytic Vapor-Liquid-Solid (VLS) growth mechanism was responsible for the growth of In2O3 nanowires. Effect of oxygen partial pressure variation and variation of applied currents to the evaporation boat on the nanowires growth was systematically studied. These studies concluded that at oxygen partial pressure in the range of 4 x 10(-4), 6 x 10(-4) mbar at applied currents to the evaporation boat of 180-200 A were the best conditions for good nanowires growth. Finally, we observed another mode of VLS growth along with the standard VLS growth mode for In2O3 nanowires similar to the growth mechanism reported for GaAs nanowires.

10.
ACS Appl Mater Interfaces ; 6(10): 7108-16, 2014 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-24773266

RESUMO

We report on the systematic comparative study of highly c-axis oriented and crystalline piezoelectric ZnO thin films deposited on four different flexible substrates for vibration sensing application. The flexible substrates employed for present experimental study were namely a metal alloy (Phynox), metal (aluminum), polyimide (Kapton), and polyester (Mylar). ZnO thin films were deposited by an RF reactive magnetron sputtering technique. ZnO thin films of similar thicknesses of 700 ± 30 nm were deposited on four different flexible substrates to have proper comparative studies. The crystallinity, surface morphology, chemical composition, and roughness of ZnO thin films were evaluated by respective material characterization techniques. The transverse piezoelectric coefficient (d31) value for assessing the piezoelectric property of ZnO thin films on different flexible substrates was measured by a four-point bending method. ZnO thin films deposited on Phynox alloy substrate showed relatively better material characterization results and a higher piezoelectric d31 coefficient value as compared to ZnO films on metal and polymer substrates. In order to experimentally verify the above observations, vibration sensing studies were performed. As expected, the ZnO thin film deposited on Phynox alloy substrate showed better vibration sensing performance. It has generated the highest peak to peak output voltage amplitude of 256 mV as compared to that of aluminum (224 mV), Kapton (144 mV), and Mylar (46 mV). Therefore, metal alloy flexible substrate proves to be a more suitable, advantageous, and versatile choice for integrating ZnO thin films as compared to metal and polymer flexible substrates for vibration sensing applications. The present experimental study is extremely important and helpful for the selection of a suitable flexible substrate for various applications in the field of sensor and actuator technology.

11.
Am J Rhinol Allergy ; 28(1): e62-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24717887

RESUMO

BACKGROUND: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. METHODS: Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. RESULTS: Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. CONCLUSION: The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.


Assuntos
Técnicas de Diagnóstico do Sistema Respiratório/instrumentação , Obstrução Nasal/diagnóstico , Septo Nasal/patologia , Polivinil , Adulto , Idoso , Feminino , Humanos , Inalação , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
12.
J Clin Monit Comput ; 27(6): 647-57, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23771706

RESUMO

Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 ± 4.1) and the RIP (19.57 ± 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.


Assuntos
Monitorização Fisiológica/instrumentação , Nariz/fisiologia , Polivinil/química , Respiração , Transdutores , Adulto , Ar , Calibragem , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pletismografia , Reprodutibilidade dos Testes , Taxa Respiratória , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Adulto Jovem
13.
ScientificWorldJournal ; 2012: 456516, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22654610

RESUMO

Kinetics of Ru (III) catalyzed oxidation of aliphatic ketones such as acetone, ethyl methyl ketone, diethyl ketone, iso-butylmethyl ketone by N-bromosuccinimide in the presence of Hg(II) acetate have been studied in aqueous acid medium. The order of [N-bromosuccinimide] was found to be zero both in catalyzed as well as uncatalyzed reactions. However, the order of [ketone] changed from unity to a fractional one in the presence of Ru (III). On the basis of kinetic features, the probable mechanisms are discussed and individual rate parameters evaluated.


Assuntos
Ácido Acético/química , Bromosuccinimida/química , Rubídio/química , Catálise , Cinética , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...