Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 6001, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472232

RESUMO

The rapid progress that plasma wakefield accelerators are experiencing is now posing the question as to whether they could be included in the design of the next generation of high-energy electron-positron colliders. However, the typical structure of the accelerating wakefields presents challenging complications for positron acceleration. Despite seminal proof-of-principle experiments and theoretical proposals, experimental research in plasma-based acceleration of positrons is currently limited by the scarcity of positron beams suitable to seed a plasma accelerator. Here, we report on the first experimental demonstration of a laser-driven source of ultra-relativistic positrons with sufficient spectral and spatial quality to be injected in a plasma accelerator. Our results indicate, in agreement with numerical simulations, selection and transport of positron beamlets containing N e + ≥ 10 5 positrons in a 5% bandwidth around 600 MeV, with femtosecond-scale duration and micron-scale normalised emittance. Particle-in-cell simulations show that positron beams of this kind can be guided and accelerated in a laser-driven plasma accelerator, with favourable scalings to further increase overall charge and energy using PW-scale lasers. The results presented here demonstrate the possibility of performing experimental studies of positron acceleration in a laser-driven wakefield accelerator.

2.
Nat Commun ; 11(1): 6355, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33311487

RESUMO

Laser wakefield accelerators promise to revolutionize many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimization of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimized its outputs by simultaneously varying up to six parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimization of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

4.
Sci Rep ; 9(1): 4471, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30872656

RESUMO

Protontherapy has emerged as more effective in the treatment of certain tumors than photon based therapies. However, significant capital and operational costs make protontherapy less accessible. This has stimulated interest in alternative proton delivery approaches, and in this context the use of laser-based technologies for the generation of ultra-high dose rate ion beams has been proposed as a prospective route. A better understanding of the radiobiological effects at ultra-high dose-rates is important for any future clinical adoption of this technology. In this study, we irradiated human skin fibroblasts-AG01522B cells with laser-accelerated protons at a dose rate of 109 Gy/s, generated using the Gemini laser system at the Rutherford Appleton Laboratory, UK. We studied DNA double strand break (DSB) repair kinetics using the p53 binding protein-1(53BP1) foci formation assay and observed a close similarity in the 53BP1 foci repair kinetics in the cells irradiated with 225 kVp X-rays and ultra- high dose rate protons for the initial time points. At the microdosimetric scale, foci per cell per track values showed a good correlation between the laser and cyclotron-accelerated protons indicating similarity in the DNA DSB induction and repair, independent of the time duration over which the dose was delivered.


Assuntos
Quebras de DNA de Cadeia Dupla , Fibroblastos/efeitos da radiação , Terapia com Prótons/instrumentação , Proteína 1 de Ligação à Proteína Supressora de Tumor p53/metabolismo , Linhagem Celular , Ciclotrons/instrumentação , Relação Dose-Resposta à Radiação , Fibroblastos/química , Fibroblastos/citologia , Humanos , Lasers , Estudos Prospectivos , Terapia com Prótons/efeitos adversos
5.
Sci Rep ; 9(1): 3249, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30824838

RESUMO

Laser-wakefield accelerators (LWFAs) are high acceleration-gradient plasma-based particle accelerators capable of producing ultra-relativistic electron beams. Within the strong focusing fields of the wakefield, accelerated electrons undergo betatron oscillations, emitting a bright pulse of X-rays with a micrometer-scale source size that may be used for imaging applications. Non-destructive X-ray phase contrast imaging and tomography of heterogeneous materials can provide insight into their processing, structure, and performance. To demonstrate the imaging capability of X-rays from an LWFA we have examined an irregular eutectic in the aluminum-silicon (Al-Si) system. The lamellar spacing of the Al-Si eutectic microstructure is on the order of a few micrometers, thus requiring high spatial resolution. We present comparisons between the sharpness and spatial resolution in phase contrast images of this eutectic alloy obtained via X-ray phase contrast imaging at the Swiss Light Source (SLS) synchrotron and X-ray projection microscopy via an LWFA source. An upper bound on the resolving power of 2.7 ± 0.3 µm of the LWFA source in this experiment was measured. These results indicate that betatron X-rays from laser wakefield acceleration can provide an alternative to conventional synchrotron sources for high resolution imaging of eutectics and, more broadly, complex microstructures.

6.
Rev Sci Instrum ; 90(1): 013301, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709173

RESUMO

Optical Kerr gating technique has been employed to investigate the life history of relativistic electrons in solids by temporally gating their Cherenkov emission. Mega-ampere currents of relativistic electrons are created during ultra-intense (2 × 1019 W/cm2) laser-solid interactions. In order to measure the lifetime of these relativistic electrons in solids, we temporally gate their Cherenkov emission using an optical Kerr gate (OKG). The OKG is induced in a nonlinear medium, namely, carbon-di-sulphide (CS2), with a measured gate-width (FWHM) of 2 ps. The gate femtosecond laser pulse is synchronized with the intense interaction pulse generating relativistic electrons. The arrival time of the gate laser pulse on the CS2 cell is varied with the help of a delay stage. We find that Cherenkov emission from relativistic electrons created with a ultra-short laser pulse (25 fs) lives as long as 120 ps, a few thousand times that of the incident light pulse.

7.
Phys Rev Lett ; 120(25): 254801, 2018 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-29979081

RESUMO

We report on the depletion and power amplification of the driving laser pulse in a strongly driven laser wakefield accelerator. Simultaneous measurement of the transmitted pulse energy and temporal shape indicate an increase in peak power from 187±11 TW to a maximum of 318±12 TW after 13 mm of propagation in a plasma density of 0.9×10^{18} cm^{-3}. The power amplification is correlated with the injection and acceleration of electrons in the nonlinear wakefield. This process is modeled by including a localized redshift and subsequent group delay dispersion at the laser pulse front.

8.
Phys Rev Lett ; 120(6): 065001, 2018 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-29481271

RESUMO

We report the lifetime of intense-laser (2×10^{19} W/cm^{2}) generated relativistic electron pulses in solids by measuring the time evolution of their Cherenkov emission. Using a picosecond resolution optical Kerr gating technique, we demonstrate that the electrons remain relativistic as long as 50 picoseconds-more than 1000 times longer than the incident light pulse. Numerical simulations of the propagation of relativistic electrons and the emitted Cherenkov radiation with Monte Carlo geant4 package reproduce the striking experimental findings.

9.
Sci Rep ; 7(1): 8347, 2017 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-28827645

RESUMO

The transport of hot, relativistic electrons produced by the interaction of an intense petawatt laser pulse with a solid has garnered interest due to its potential application in the development of innovative x-ray sources and ion-acceleration schemes. We report on spatially and temporally resolved measurements of megagauss magnetic fields at the rear of a 50-µm thick plastic target, irradiated by a multi-picosecond petawatt laser pulse at an incident intensity of ~1020 W/cm2. The pump-probe polarimetric measurements with micron-scale spatial resolution reveal the dynamics of the magnetic fields generated by the hot electron distribution at the target rear. An annular magnetic field profile was observed ~5 ps after the interaction, indicating a relatively smooth hot electron distribution at the rear-side of the plastic target. This is contrary to previous time-integrated measurements, which infer that such targets will produce highly structured hot electron transport. We measured large-scale filamentation of the hot electron distribution at the target rear only at later time-scales of ~10 ps, resulting in a commensurate large-scale filamentation of the magnetic field profile. Three-dimensional hybrid simulations corroborate our experimental observations and demonstrate a beam-like hot electron transport at initial time-scales that may be attributed to the local resistivity profile at the target rear.

10.
Sci Rep ; 6: 32041, 2016 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-27557592

RESUMO

We describe the first demonstration of plasma mirrors made using freely suspended, ultra-thin films formed dynamically and in-situ. We also present novel particle-in-cell simulations that for the first time incorporate multiphoton ionization and dielectric models that are necessary for describing plasma mirrors. Dielectric plasma mirrors are a crucial component for high intensity laser applications such as ion acceleration and solid target high harmonic generation because they greatly improve pulse contrast. We use the liquid crystal 8CB and introduce an innovative dynamic film formation device that can tune the film thickness so that it acts as its own antireflection coating. Films can be formed at a prolonged, high repetition rate without the need for subsequent realignment. High intensity reflectance above 75% and low-field reflectance below 0.2% are demonstrated, as well as initial ion acceleration experimental results that demonstrate increased ion energy and yield on shots cleaned with these plasma mirrors.

11.
Nat Commun ; 6: 8742, 2015 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-26541650

RESUMO

Since the observation of the first brown dwarf in 1995, numerous studies have led to a better understanding of the structures of these objects. Here we present a method for studying material resistivity in warm dense plasmas in the laboratory, which we relate to the microphysics of brown dwarfs through viscosity and electron collisions. Here we use X-ray polarimetry to determine the resistivity of a sulphur-doped plastic target heated to Brown Dwarf conditions by an ultra-intense laser. The resistivity is determined by matching the plasma physics model to the atomic physics calculations of the measured large, positive, polarization. The inferred resistivity is larger than predicted using standard resistivity models, suggesting that these commonly used models will not adequately describe the resistivity of warm dense plasma related to the viscosity of brown dwarfs.

12.
Philos Trans A Math Phys Eng Sci ; 372(2010): 20130032, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24470414

RESUMO

Advances in X-ray imaging techniques have been driven by advances in novel X-ray sources. The latest fourth-generation X-ray sources can boast large photon fluxes at unprecedented brightness. However, the large size of these facilities means that these sources are not available for everyday applications. With advances in laser plasma acceleration, electron beams can now be generated at energies comparable to those used in light sources, but in university-sized laboratories. By making use of the strong transverse focusing of plasma accelerators, bright sources of betatron radiation have been produced. Here, we demonstrate phase-contrast imaging of a biological sample for the first time by radiation generated by GeV electron beams produced by a laser accelerator. The work was performed using a greater than 300 TW laser, which allowed the energy of the synchrotron source to be extended to the 10-100 keV range.

13.
Opt Express ; 22(24): 29363-74, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25606870

RESUMO

We propose, for the first time, a transmission grating stretcher for high power lasers and demonstrate its superiority over conventional, reflective gold grating stretchers in terms of pulse temporal quality. We show that, compared to a conventional stretcher with the same stretching factor, the transmission-grating based stretcher yields more than an order of magnitude improvement in the contrast pedestal. We have also quantitatively characterized the roughness of the grating surfaces and estimated its impact on the contrast pedestal.


Assuntos
Lasers , Óptica e Fotônica/instrumentação , Ouro , Análise Espectral , Propriedades de Superfície , Fatores de Tempo
14.
Rev Sci Instrum ; 84(11): 113302, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24289391

RESUMO

Compton side-scattering has been used to simultaneously downshift the energy of keV to MeV energy range photons while attenuating their flux to enable single-shot, spectrally resolved, measurements of high flux X-ray sources to be undertaken. To demonstrate the technique a 1 mm thick pixelated cadmium telluride detector has been used to measure spectra of Compton side-scattered radiation from a Cobalt-60 laboratory source and a high flux, high peak brilliance X-ray source of betatron radiation from a laser-plasma wakefield accelerator.

15.
Opt Express ; 19(3): 2193-203, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21369037

RESUMO

We report on an experimental study of the "coherent" contrast feature that frequently appears in petawatt(PW)-class laser pulses as an exponentially-rising pedestal within a few tens of picoseconds of the compressed pulse. We show that scattering from the diffraction gratings in the stretcher is the principal source of this feature. Replacing the gratings by new, higher-quality components resulted in an order-of-magnitude reduction in the intensity of the pedestal.


Assuntos
Lasers , Refratometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
16.
Phys Rev Lett ; 105(10): 105002, 2010 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-20867525

RESUMO

We present high resolution measurements of the ultrafast temporal dynamics of the critical surface in moderately overdense, hot plasma by using two-color, pump-probe Doppler spectrometry. Our measurements clearly capture the initial inward motion of the plasma inside the critical surface of the pump laser which is followed by outward expansion. The measured instantaneous velocity and acceleration profiles are very well reproduced by a hybrid simulation that uses a 1D electromagnetic particle-in-cell simulation for the initial evolution and a hydrodynamics simulation for the later times. The combination of high temporal resolution and dynamic range in our measurements clearly provides quantitative unraveling of the dynamics in this important region, enabling this as a powerful technique to obtain ultrafast snapshots of plasma density and temperature profiles for providing benchmarks for simulations.

17.
Phys Rev Lett ; 105(23): 235003, 2010 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-21231474

RESUMO

We present complete experimental characterization of the temporal shape of an intense ultrashort 200-TW laser pulse driving a laser wakefield. The phase of the pulse was uniquely measured by using (second-order) frequency-resolved optical gating. The pulses are asymmetrically compressed and exhibit a positive chirp consistent with the expected asymmetric self-phase-modulation due to photon acceleration or deceleration in a relativistic plasma wave. The measured pulse duration decreases linearly with increasing length and density of the plasma, in quantitative agreement with the intensity-dependent group velocity variation in the plasma wave.

18.
Phys Rev Lett ; 103(3): 035002, 2009 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-19659287

RESUMO

The acceleration of electrons to approximately 0.8 GeV has been observed in a self-injecting laser wakefield accelerator driven at a plasma density of 5.5x10(18) cm(-3) by a 10 J, 55 fs, 800 nm laser pulse in the blowout regime. The laser pulse is found to be self-guided for 1 cm (>10zR), by measurement of a single filament containing >30% of the initial laser energy at this distance. Three-dimensional particle in cell simulations show that the intensity within the guided filament is amplified beyond its initial focused value to a normalized vector potential of a0>6, thus driving a highly nonlinear plasma wave.

19.
Phys Rev Lett ; 102(8): 083001, 2009 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-19257734

RESUMO

From the pulse length dependence of the absorption of intense ultrashort laser pulses focused inside fused silica, we reveal the role field-assisted collisional ionization plays in the multiphoton ionization process. This constitutes a cold avalanche ionization mechanism that persists at pulse lengths considered too short for a traditional avalanche.

20.
Phys Rev Lett ; 101(24): 243001, 2008 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-19113617

RESUMO

Using different crystalline dielectrics and intense femtosecond laser pulses, we show that nonlinear absorption depends on sample orientation. This arises primarily because of the direction dependence of the effective mass of the electron. The multiphoton nature of the interaction creates a local probe that can be used anywhere in the material. We show that the structure of crystal quartz is not changed by repeated illumination of the focal region with 45 fs pulses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...