Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 38(4): 194-203, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24567285

RESUMO

This publication describes a method for the determination of total bisphenol A (BPA and conjugated BPA) following enzyme hydrolysis and is intended as a companion to our previously developed analytical method for the determination of free BPA (the aglycone) in human blood and urine using high-performance liquid chromatography-tandem mass spectrometry ( 1). That free BPA method provided a means to account for and/or eliminate background contamination and demonstrated accuracy and reproducibility in both matrices fortified with BPA or a surrogate analyte ((13)C BPA) at a low method quantitation limit (MQL) of 0.1-0.2 ng/mL. In contrast to the free BPA method results and based on stringent accuracy, precision and confirmation criteria set for the MQLs of the method developed for total BPA, the MQL achieved in blood was 1.020-2.550 and 0.510-1.020 ng/mL in urine. These data showed higher MQLs than the desired MQLs of 0.5 ng/mL (blood) and 0.2 ng/mL (urine) with increased variability between analyses which demonstrates the importance of generating method validation data with each analysis. In contrast, the MQL achieved for (13)C BPA-G (monoglucuronide as a surrogate analyte in blood was 0.2-0.5 and 0.2 ng/mL in urine illustrating that the method is capable of meeting lower MQL requirements if the contribution from exogenous BPA can be well controlled. This method for the determination total BPA in human blood and urine is intended to be used in conjunction with the free BPA method ( 1) to obtain accurate and complete BPA biomonitoring data to support human exposure assessments.


Assuntos
Compostos Benzidrílicos , Cromatografia Líquida de Alta Pressão/métodos , Monitoramento Ambiental/métodos , Poluentes Ambientais , Fenóis , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Compostos Benzidrílicos/sangue , Compostos Benzidrílicos/urina , Calibragem , Cromatografia Líquida de Alta Pressão/instrumentação , Monitoramento Ambiental/instrumentação , Poluentes Ambientais/sangue , Poluentes Ambientais/urina , Humanos , Limite de Detecção , Fenóis/sangue , Fenóis/urina , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas em Tandem/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...