Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Indian Soc Periodontol ; 25(4): 320-329, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34393403

RESUMO

BACKGROUND: Multiple gingival recession (MGR) coverage, especially in esthetic area, demands a high patient satisfaction. Coronally advanced flap modifications, namely Zucchelli's technique (ZT) and vestibular incision subperiosteal tunnel access (VISTA), are techniques, recommended in the correction of MGR. AIM: The purpose was to comparatively analyze the ZT and VISTA technique reinforced with the platelet-rich fibrin membrane in the management of MGR. MATERIALS AND METHODS: This split-mouth, randomized study comprised 16 consenting, systemically healthy participants. The bilateral Miller's multiple class I and II lesions were managed with ZT and VISTA technique and had a follow-up period of 18 months. Gingival thickness (GT), mean percentage of root coverage, and patient-centered outcome scales, including patient comfort score, patient esthetic score, and hypersensitivity score, were the primary outcome measures. Further clinical parameters assessed were gingival index, probing depth, clinical attachment level, and width of keratinized gingiva. STATISTICAL ANALYSIS AND RESULTS: Paired t-test and unpaired t-test were used for intragroup comparison and intergroup analysis, respectively. While both the techniques exhibited high root coverage percentage (VISTA: 93.95% and ZT: 96.84%), statistically significant difference was noted with patient esthetic score and surgical mortality score in VISTA. CONCLUSION: Both ZT and VISTA were effective in terms of root coverage and GT augmentation in MGR management. From the patient's perspective, they preferred VISTA technique over ZT, stating its minimal postoperative morbidity and improved esthetic outcome. Hence, within the limitations of this study, the VISTA technique was found to be a superior alternative compared to that of ZT in MGR management.

2.
J Pharm Bioallied Sci ; 13(Suppl 1): S284-S288, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34447094

RESUMO

BACKGROUND: Peri implant infection in dental implantology is a frequently encountered clinical problem. Titania nanotubes (TNTs) are recent improvement in surface characterization, showing promising results. AIM: The nanosurface parameter tweaking has been implicated with profound change in the microbiological and biological response. Hence, it was proposed that alteration in the nanotube diameter could have positive influence in its antibacterial activity against salient periodontal pathogens. MATERIALS AND METHODS: Commercially, pure titanium discs of 8-mm diameter and 1.5-mm thickness were prepared. Polished titanium discs were used as control (Group A). Vertically oriented, structured TNTs were fabricated by anodization technique and grouped as B and C, having nanotube diameter, 40 and 80 nm subsequently. The surface characterizations of the samples were done by scanning electron microscope analysis. The antibacterial activity was evaluated with the bacterial colony counting method, at 24 h, 72 h, and 1-week intervals. STATISTICAL ANALYSIS: The one-way analysis of variance and Tukey's honest significance post hoc test were employed to assess the statistical significance. RESULTS: The 80 nm nanotubes showed better antibacterial activity comparatively, at all three-time intervals investigated. CONCLUSION: The optimal TNT diameter of 80 nm was the most effective from an antimicrobial stand point of view.

3.
J Pharm Bioallied Sci ; 13(Suppl 2): S1496-S1500, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35018017

RESUMO

AIM: Three-dimensional (3D) printed models are contemporary volumetric bone graft assessment technique for secondary alveolar bone grafting (SABG) in cleft lip and palate (CLP) patients. The study aimed at evaluation of long-term stability of iliac autograft in SABG using multislice computed tomography (CT) and 3D-printed model-based volumetric analysis. MATERIALS AND METHODS: Twenty-eight patients were included in this prospective clinical study. CT image (T1) was taken after orthodontic maxillary expansion, correlating with the presurgical image. Furthermore, 3D-printed model was prepared, and volumetric assessment of graft needed was ascertained with water displacement technique. SABG was carried on with the anterior iliac crest autografting procedure. After 1-year follow-up, postoperative CT analysis (T2) was followed upon. RESULTS: The stability of bone graft at the 1-year postoperative was found to be 43.74% with mean bone loss of 56.26% (95% confidence interval; P < 0.005). The moderate scale of CLP cases has shown statistically significant bone stability compared to that of severe and mild cases. Furthermore, the 3D-printed model has shown a significant difference to that of T1 CT imaging (P < 0.005). CONCLUSION: Within the limitations of the study, it seems appropriate to conclude that 3D-printed models serves as better reference than CT imaging in the context of planning and execution of precise bone grafting in SABG.

4.
Indian J Dent Res ; 27(3): 256-61, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27411653

RESUMO

CONTEXT: The substantial knowledge concerning ergonomics and its practical application is vital for forestalling musculoskeletal disorders. The role of equipment ergonomics (EE) in preventing these work-related ailments is significantly noteworthy. AIM: The aim of the study was to assess the prevailing perception of postgraduates (PGs) and interns regarding EE and preparing the Indian dental workforce for the challenges of India's growing economy and population. SETTINGS AND DESIGN: Authors conducted a cross-sectional survey between December 2013 and February 2014 amidst the interns and PG dental students of Davangere city, Karnataka, India. SUBJECTS AND METHODS: The data were collected using 21-item custom designed proforma, comprising of questions evaluating student's basic knowledge about EE. STATISTICAL ANALYSIS USED: Statistical analysis was done using Chi-square test in each group (PGs and interns) and Mann-Whitney test was implemented for comparison between both groups. RESULTS: Of 358 subjects surveyed, 48% PGs and 52% interns affirmed that they came across EE only through this survey. In addition, 91.18% of PGs and 90.59% interns believed that the accentuation on EE is less in the current dental curriculum. CONCLUSIONS: Comprehensive understanding and practical application of EE among the participants was found to be lacking. The importance of microbreaks and chair side exercises should be emphasized and training should be initiated at an early stage before improper postural habits develop.


Assuntos
Equipamentos Odontológicos , Ergonomia , Conhecimentos, Atitudes e Prática em Saúde , Internato e Residência , Estudantes de Odontologia , Adulto , Estudos Transversais , Currículo , Feminino , Humanos , Índia , Masculino , Inquéritos e Questionários
5.
ScientificWorldJournal ; 2016: 6854303, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26881272

RESUMO

Wireless sensor networks (WSNs) consist of lightweight devices with low cost, low power, and short-ranged wireless communication. The sensors can communicate with each other to form a network. In WSNs, broadcast transmission is widely used along with the maximum usage of wireless networks and their applications. Hence, it has become crucial to authenticate broadcast messages. Key management is also an active research topic in WSNs. Several key management schemes have been introduced, and their benefits are not recognized in a specific WSN application. Security services are vital for ensuring the integrity, authenticity, and confidentiality of the critical information. Therefore, the authentication mechanisms are required to support these security services and to be resilient to distinct attacks. Various authentication protocols such as key management protocols, lightweight authentication protocols, and broadcast authentication protocols are compared and analyzed for all secure transmission applications. The major goal of this survey is to compare and find out the appropriate protocol for further research. Moreover, the comparisons between various authentication techniques are also illustrated.

6.
Contemp Clin Dent ; 6(3): 299-304, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26321824

RESUMO

BACKGROUND AND OBJECTIVE: Transmucosal analgesic delivery is a promising approach to periodontal postoperative pain management. The purpose of this clinical trial is to appraise the effectiveness of transmucosal drug delivery system with meloxicam films and to identify its minimum effective dosage via this route after periodontal flap surgery. MATERIALS AND METHODS: The analgesic mucoadhesive films were formulated using meloxicam and hydroxypropyl methyl cellulose polymer by solvent casting method. The sample size consisted of 60 chronic periodontitis patients who require periodontal flap surgery. The subjects were randomized using lottery method into four groups (Group A - 45 mg; B - 30 mg; C - 20 mg; D - 10 mg meloxicam per film). After periodontal flap surgery, the respective meloxicam mucoadhesive films were placed over the surgical site and were removed on 4(th) day of postsurgery. The primary outcome measure was postsurgical pain level and recorded at 1(st), 2(nd), 3(rd), 4(th), 5(th), 24(th), and 48(th) h using a 0-10 mm visual analog scale with markings from 0 = no pain to 10 = extreme pain. RESULTS: The postoperative pain control observed in Groups A and B was found to be effective, and the patient comfort level was very satisfactory. Whereas in Group C, it was found to be high in the first 3 h postsurgically, after which adequate pain relief was seen. Group D exhibited inadequate pain relief. No adverse reactions were noted after applying the film in any of the groups. CONCLUSION: Transmucosal delivery of meloxicam was found to be effective and safe in postsurgical pain control of periodontal flap surgery. The minimum effective dosage via this route for meloxicam was found to be with 30 mg mucoadhesive films.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...