Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nucl Instrum Methods Phys Res A ; 830: 119-129, 2016 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-27746514

RESUMO

A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution responding to 511 keV photons are measured to be ~32% and ~510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.

2.
Nucl Instrum Methods Phys Res A ; 784: 557-564, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25937685

RESUMO

We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 Tesla small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 × 8 LYSO scintillators (5.0 × 5.0 × 10.0 mm3 with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner.

3.
Nucl Instrum Methods Phys Res A ; 767: 67-74, 2014 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-25506113

RESUMO

We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

4.
Phys Rev Lett ; 107(20): 201803, 2011 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-22181724

RESUMO

The KTeV E799 experiment has conducted a search for the rare decays, K(L)→π(0)π(0)µ(+)µ(-) and K(L)→π(0)π(0)X(0)→π(0)π(0)µ(+)µ(-), where the X(0) is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 ± 0.5) MeV/c(2). We find no evidence for either decay. We obtain upper limits of Br(K(L)→π(0)π(0)X(0)→π(0)π(0)µ(+)µ(-)) < 1.0 × 10(-10) and Br(K(L)→π(0)π(0)µ(+)µ(-)) < 9.2 × 10(-11) at the 90% confidence level. This result rules out the pseudoscalar X(0) as an explanation of the HyperCP result under the scenario that the dsX(0) coupling is completely real.

5.
Phys Rev Lett ; 106(13): 131302, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21517371

RESUMO

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below ∼10 GeV/c(2). This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c(2) and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

6.
Phys Rev Lett ; 106(2): 021303, 2011 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-21405218

RESUMO

Data from the operation of a bubble chamber filled with 3.5 kg of CF3I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg day, consistent with a neutron background. This observation provides strong direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering for WIMP masses >20 GeV/c2.

7.
Science ; 327(5973): 1619-21, 2010 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-20150446

RESUMO

Astrophysical observations indicate that dark matter constitutes most of the mass in our universe, but its nature remains unknown. Over the past decade, the Cryogenic Dark Matter Search (CDMS II) experiment has provided world-leading sensitivity for the direct detection of weakly interacting massive particle (WIMP) dark matter. The final exposure of our low-temperature germanium particle detectors at the Soudan Underground Laboratory yielded two candidate events, with an expected background of 0.9 +/- 0.2 events. This is not statistically significant evidence for a WIMP signal. The combined CDMS II data place the strongest constraints on the WIMP-nucleon spin-independent scattering cross section for a wide range of WIMP masses and exclude new parameter space in inelastic dark matter models.

8.
Phys Rev Lett ; 103(14): 141802, 2009 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-19905561

RESUMO

We report on the first axion search results from the Cryogenic Dark Matter Search (CDMS) experiment at the Soudan Underground Laboratory. An energy threshold of 2 keV for electron-recoil events allows a search for possible solar axion conversion into photons or local galactic axion conversion into electrons in the germanium crystal detectors. The solar axion search sets an upper limit on the Primakov coupling g(agammagamma) of 2.4x10(-9) GeV-1 at the 95% confidence level for an axion mass less than 0.1 keV/c2. This limit benefits from the first precise measurement of the absolute crystal plane orientations in this type of experiment. The galactic axion search analysis sets a world-leading experimental upper limit on the axioelectric coupling g(aee) of 1.4x10(-12) at the 90% confidence level for an axion mass of 2.5 keV/c2.

9.
Phys Rev Lett ; 102(1): 011301, 2009 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-19257177

RESUMO

We report results from the Cryogenic Dark Matter Search at the Soudan Underground Laboratory (CDMS II) featuring the full complement of 30 detectors. A blind analysis of data taken between October 2006 and July 2007 sets an upper limit on the weakly interacting massive particle (WIMP) nucleon spin-independent cross section of 6.6x10;{-44} cm;{2} (4.6x10;{-44} cm;{2} when combined with previous CDMS II data) at the 90% confidence level for a WIMP mass of 60 GeV/c;{2}. This achieves the best sensitivity for dark matter WIMPs with masses above 44 GeV/c;{2}, and significantly restricts the parameter space for some favored supersymmetric models.

10.
Phys Rev Lett ; 101(19): 191802, 2008 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-19113260

RESUMO

Three events for the decay K+-->pi+ nunu have been observed in the pion momentum region below the K+-->pi+pi0 peak, 140 < Ppi < 199 MeV/c, with an estimated background of 0.93+/-0.17(stat.) -0.24+0.32(syst.) events. Combining this observation with previously reported results yields a branching ratio of B(K+-->pi+ nunu) = (1.73(-1.05)+1.15) x 10(-10) consistent with the standard model prediction.

11.
Phys Rev Lett ; 100(13): 131803, 2008 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-18517936

RESUMO

The Fermilab KTeV experiment has searched for lepton-flavor-violating decays of the K(L) meson in three decay modes. We observe no events in the signal region for any of the modes studied, and we set the following upper limits for their branching ratios at the 90% C.L.: BR(K(L) --> pi(0) micro(+/-) e(-/+)) <7.6 x 10(-11); BR(K(L) --> pi(0)pi(0) micro(+/-) e(-/+)) <1.7 x 10(-10); BR(pi(0) --> micro(+/-) e(-/+)) <3.6 x 10(-10). This result represents a factor of 82 improvement in the branching ratio limit for K(L) --> pi(0) micro(+/-) e(-/+) and is the first reported limit for K(L) --> pi(0)pi(0) micro(+/-) e(-/+).

12.
Phys Rev Lett ; 100(18): 182001, 2008 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-18518364

RESUMO

We present a new determination of the parity of the neutral pion via the double Dalitz decay pi0-->e+e-e+e-. Our sample, which consists of 30,511 candidate decays, was collected from KL-->pi0pi0pi0 decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative pi0 parity and place a limit on scalar contributions to the pi0-->e+e-e+e- decay amplitude of less than 3.3% assuming CPT conservation. The pi0gamma*gamma* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase-space distribution. Additionally, we have measured the branching ratio of this mode to be B(pi0-->e+e-e+e-)=(3.26+/-0.18)x10(-5).

13.
Science ; 319(5865): 933-6, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18276885

RESUMO

Bubble chambers were the dominant technology used for particle detection in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on a new application for these devices. We operated an ultraclean, room-temperature bubble chamber containing 1.5 kilograms of superheated CF3I, a target maximally sensitive to spin-dependent and -independent weakly interacting massive particle (WIMP) couplings. An extreme intrinsic insensitivity to the backgrounds that commonly limit direct searches for dark matter was measured in this device under operating conditions leading to the detection of low-energy nuclear recoils like those expected from WIMPs. Improved limits on the spin-dependent WIMP-proton scattering cross section were extracted during our experiments, excluding this type of coupling as a possible explanation for a recent claim of particle dark-matter detection.

14.
Phys Rev Lett ; 99(5): 051804, 2007 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-17930743

RESUMO

The E799-II (KTeV) experiment at Fermilab has collected 83 262 K(L)-->e+ e- gamma(gamma) events above a background of 79 events. We measure a decay width, normalized to the K(L)-->pi0pi0pi(D)0 (pi0-->gammagamma, pi0-->gammagamma, pi(D0-->e+ e- gamma(gamma)) decay width, of Gamma(K(L)-->e+e-gamma(gamma))/Gamma(K(L)-->pi0pi0pi(D)0)=(1.3302+/-0.0046(stat)+/-0.0102(syst)) x 10(-3). We also measure parameters of two K(L)gamma*gamma form factor models. In the Bergström-Massó-Singer parametrization, we find Calpha(K*)= -0.517 +/- 0.030(stat) +/- 0.022(syst). We separately fit for the first parameter of the D'Ambrosio-Isidori-Portolés model and find alpha(DIP)= -1.729 +/- 0.043(stat) +/- 0.028(syst).

15.
Phys Rev Lett ; 99(8): 081803, 2007 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-17930940

RESUMO

This Letter is the first report of the K{L}-->pi{+/-}e{-/+}nue{+}e{-} decay. Based on 19 208+/-144 events, we determine the branching fraction, B(K{L}-->pi{+/-}e{-/+}nue{+}e{-}M_{e{+}e{-}}>5 MeV/c{2},E{e{+}e{-}}{*}>30 MeV)=(1.285+/-0.041)x10{-5}, and Gamma(K{e3ee}M{e{+}e{-}}>5 MeV/c{2})/Gamma(K{e3})=[4.57+/-0.04(stat)+/-0.14(syst)]x10{-5}. This ratio agrees with a theoretical prediction based on chiral perturbation theory (ChPT) calculated to O(p{4}). The measured kinematical distributions agree with those predicted by just ChPT O(p{4}), but show significant disagreement with ones predicted by leading-order ChPT.

16.
Phys Rev Lett ; 96(10): 101801, 2006 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-16605723

RESUMO

Using the complete KTeV data set of 5,241 candidate K(L)--> pi(+) pi(-) e(+) e(-) decays (including an estimated background of 204 +/- 14 events), we have measured the coupling g(CR)= 0.163 +/- 0.0149(stat) +/- 0.023(syst) of the CP conserving charge radius process and from it determined a K(0) charge radius of = [-0.077 +/- 0.007(stat) +/- 0.011(syst)]fm(2). We have determined a first experimental upper limit of 0.04 (90% C.L.) /g(e1)/ / /g(M1)/ of the couplings for the E1 and M1 direct photon emission processes. We also report the measurement of /g(M1)/ including a vector form factor /g(M1)/(1 + (a(1)/a(2))/((M(2)(p)-(M(2)(k))= 2M(K)E(gamma*)), where vector /g(M1)/= 1.11+/- 0.12(stat) +/- 0.08(syst) and a(1)/a(2) = [-0.744 +/- 0.027(stat) +/- 0.032(syst)] GeV(2)/c(2). Finally, a CP-violating asymmetry of [13.6 +/- 1.4(stat) +/- 1.5(syst)]% in the CP and T odd angle phi between the decay planes of the e(+) e(-) and pi(+) pi(-) pairs in the K(L) center of mass is reported.

17.
Phys Rev Lett ; 96(1): 011302, 2006 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-16486434

RESUMO

We report new results from the Cryogenic Dark Matter Search (CDMS II) at the Soudan Underground Laboratory. Two towers, each consisting of six detectors, were operated for 74.5 live days, giving spectrum-weighted exposures of 34 (12) kg d for the Ge (Si) targets after cuts, averaged over recoil energies 10-100 keV for a weakly interacting massive particle (WIMP) mass of 60 GeV/c2. A blind analysis was conducted, incorporating improved techniques for rejecting surface events. No WIMP signal exceeding expected backgrounds was observed. When combined with our previous results from Soudan, the 90% C.L. upper limit on the spin-independent WIMP-nucleon cross section is 1.6 x 10(-43) cm2 from Ge and 3 x 10(-42) cm2 from Si, for a WIMP mass of 60 GeV/c2. The combined limit from Ge (Si) is a factor of 2.5 (10) lower than our previous results and constrains predictions of supersymmetric models.

18.
Phys Rev Lett ; 95(8): 081801, 2005 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-16196851

RESUMO

The xi0 muon semileptonic decay has been observed for the first time with nine identified events using the KTeV beam line and detector at Fermilab. The decay is normalized to the xi0 beta decay mode and yields a value for the ratio of decay rates gamma(xi0 --> sigma+ mu- nu(mu))/gamma(xi0 --> sigma+ e- nu(e)) of [1.8(-0.5)(+0.7)(stat) +/- 0.2(syst)] x 10(-2). This is in agreement with the SU(3) flavor symmetric quark model.

19.
Phys Rev Lett ; 93(18): 181802, 2004 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-15525151

RESUMO

We present a determination of the Cabibbo-Kobayashi-Maskawa parameter |V(us)| based on new measurements of the six largest K(L) branching fractions and semileptonic form factors by the KTeV (E832) experiment at Fermilab. We find |V(us)|=0.2252+/-0.0008(KTeV)+/-0.0021(ext), where the errors are from KTeV measurements and from external sources. We also use the measured branching fractions to determine the CP violation parameter |eta(+-)|=(2.228+/-0.005(KTeV)+/-0.009(ext))x10(-3).

20.
Phys Rev Lett ; 93(3): 031801, 2004 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-15323812

RESUMO

An additional event near the upper kinematic limit for K+-->pi(+)nunu; has been observed by experiment E949 at Brookhaven National Laboratory. Combining previously reported and new data, the branching ratio is B(K+-->pi(+)nunu;)=(1.47(+1.30)(-0.89))x10(-10) based on three events observed in the pion momentum region 211

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...